9500 Triple Quadrupole ICP-MS
The Agilent 9500 Triple Quadrupole ICP-MS delivers true ICP-MS/MS performance without the complexity. Its proprietary Dual-Cell System, with Advanced Helium Mode (AHM) and Air mode, enables fast, interference-free analysis across complex matrices, delivering results you can trust.
The Agilent 9500 Triple Quadrupole ICP-MS delivers true ICP-MS/MS performance without the complexity. Its proprietary Dual-Cell System, with Advanced Helium Mode (AHM) and Air mode, enables fast, interference-free analysis across complex matrices, delivering results you can trust.
Built for labs that need higher performance without workflow disruption, the 9500 ICP-QQQ simplifies method development and routine analysis. AHM replaces multiple tune modes to cut acquisition time by >33%, while Air cell uses ambient air to remove difficult interferences.
Features
- Proprietary Dual-Cell System (DCS) combines Advanced Helium Mode and Air mode for simple, powerful interference removal across complex sample matrices
- Advanced Helium Mode replaces multiple tune modes with one streamlined mode, reducing acquisition time by more than 33% for faster routine analysis
- Air cell uses ambient air for oxygen mass-shift reactions, resolving difficult on-mass interferences while eliminating extra reactive gas infrastructure and related safety concerns
- DCS with AHM combines Collision-Induced Dissociation (CID) and Kinetic Energy Discrimination (KED) in a single high-performance mode for powerful interference removal while maintaining low mass sensitivity
- Preset methods, Method Advisor, and automated method conversion tools simplify method setup and make ICP-QQQ more accessible for routine analysis
- Single quadrupole familiarity with triple quadrupole capability–less to learn, while achieving more
- Improved hardware design enhances performance and usability, including a new u-lens, Q2 mass range extended to 300 u, and a 0.05 ms minimum dwell time
- Easy-fit sample introduction, improved accessibility, and ergonomic design simplify installation and maintenance, reducing manual effort and supporting reliable day-to-day operation
- Integrated Agilent automation options support higher productivity through unattended analysis, automated dilution and calibration, and lower cost per sample
Brochures
Agilent 9500 ICP MS system delivers high-performance trace element analysis with simplified workflows
Explore how the Agilent 9500 ICP-MS system delivers triple quadrupole performance with simplified workflows for trace element analysis across complex sample matrices. Featuring a proprietary Dual-Cell System with Advanced Helium Mode and Air mode, the platform enables enhanced interference removal, improved sensitivity, and faster analysis times. Combined with automated method development tools and integrated OpenLab software, the system supports reliable, reproducible data while reducing complexity and increasing laboratory productivity.
Resource details:
- Resource type: Product brochure
- Page count: 9 pages
- Read time: 14 mins
Surveying the shift: The transition from single quadrupole ICP-MS to ICP-QQQ
Across regions and industries, laboratories are facing the same underlying challenge: extracting reliable trace element data from increasingly complex samples.
From pharmaceutical labs navigating ultra‑low impurity thresholds in regulated markets, to environmental labs tackling variable natural matrices, the pressure is mounting, not just to detect, but to detect with confidence.
This infographic maps how these challenges are playing out globally, with insights from 150+ scientists revealing why labs are accelerating the transition to ICP‑QQQ.
Resource details:
- Document type: SelectScience infographic
- Page count: 1
- Read time: 2 mins
- Edition: 1st
The next generation ICP-MS designed to wow trace element analysts
Wednesday, July 8 at 15:00 BST | 16:00 CEST | 10:00 EDT | 07:00 PDT
Trace‑element labs are under more pressure than ever to deliver fast, interference‑free results, without getting slowed down by complex matrices, method‑development hurdles, or repeat runs. When you are balancing tricky samples with tight turnaround times, the limits of single‑quadrupole inductively coupled plasma mass spectrometry (ICP‑MS) become impossible to ignore. That’s exactly where triple-quadrupole (ICP‑QQQ) technology changes the game.
Join this SelectScience® webinar for an exclusive preview at the Agilent triple quadrupole ICP‑MS. The Agilent 9500 ICP-MS is designed to help laboratories solve those exact challenges and move beyond complex method development, re-runs, and uncertainty in results.
You will hear from Dr. Gareth Pearson and Gernot Hudin, who have decades of combined experience pushing the boundaries of ICP‑MS performance, this expert duo brings a rare blend of deep technical insight and real‑world, lab‑tested know‑how. Plus, gain insights from a new independent SelectScience survey, created in partnership with Agilent, revealing what your peers really think about transitioning from single‑quad to triple‑quad ICP‑MS.
They will take you inside the workflows, challenges, and breakthroughs that matter most to trace‑element analysts, showing exactly how to boost productivity from the very first run. From mastering interference‑free analysis with the Dual‑Cell System (Advanced Helium Mode (AHM) + Air mode) to achieving seamless method transfer. Whether your goal is to scale capacity, reduce downtime, or achieve more consistent results across operators and sites, you will see how the 9500 supports efficient, disruption‑free operation.
TechTalk: Why fast, reliable trace‑element analysis starts with triple‑quad ICP‑MS
Friday, September 25 at 16:30 BST | 17:30 CEST | 11:30 EDT | 08:30 PDT
Trace‑element analysis plays a critical role across industries where fast, interference‑free results are essential. Yet many laboratories still rely on single‑quadrupole ICP‑MS systems that struggle with slow batch times, complex matrices, and inconsistent data quality. As workloads grow and expectations tighten, the need for scalable, reliable, and easy‑to‑operate technology becomes impossible to ignore.
In this SelectScience® TechTalk, Mark Kelinske, ICP‑MS Product Specialist at Agilent Technologies, takes a technology‑focused look at how the Agilent ICP‑MS 9500 is engineered to overcome these challenges. Learn how moving from single‑quad to triple‑quad workflows strengthens interference control, boosts speed, and improves data reliability, giving analysts cleaner results even when working with demanding matrices.
With Advanced Helium Mode supporting confident, interference‑resistant measurements and a usability‑driven design that keeps daily operation smooth, the 9500 delivers scalable performance built for modern labs. Plus, with its next‑generation architecture designed to grow with your needs, you will learn how the 9500 helps future‑proof your workflows while delivering the kind of performance that genuinely makes you say “wow.”
Register today and discover how the ICP‑MS 9500 accelerates throughput, enhances data confidence, simplifies method setup, and equips your laboratory with MS/MS‑ready workflows built for the future of trace‑element analysis.
Certificate of attendance
If you attend the live TechTalk, you will automatically receive a certificate of attendance, including a learning outcomes summary, for continuing education purposes. If you view the on-demand TechTalk, you can request a certificate of attendance by emailing editor@selectscience.net.
TechTalk details
- Cost: Free to attend
- Location: Online
- Duration: 20 minutes
Registration is required to secure your place. If you register but can’t attend live, you will receive a link to the on‑demand recording once it becomes available
Top mass spectrometry launches at ASMS 2026
Major vendors unveil new instruments and workflow solutions, highlighting a continued focus on performance, integration, and data-driven analysis































