Products & ReviewGeneral Lab

Multi functional range of precision top pan balances with unique features and rugged, robust design. Calibration by external weight. 220g by 0.001g

Multi functional range of precision top pan balances with unique features and rugged, robust design. Wide range of capacities from 110g to 10kg;wide range of resolutions from 0.001g to 0.1g; Patented Impact Shock Detection (ISD) for preventing damage due to sudden  shock; Patented Electronically Controlled Load (ECL) for Automatic Precision Assessment (APA) and minimum weight determination; Multi user and multi level password…

A&D Weighing

The supplier does not provide quotations for this product through SelectScience. You can search for similar products in our  Product Directory.

Ease of Use
After Sales Service
Value for Money
Be the first to leave a review
Description

Multi functional range of precision top pan balances with unique features and rugged, robust design. Wide range of capacities from 110g to 10kg;wide range of resolutions from 0.001g to 0.1g; Patented Impact Shock Detection (ISD) for preventing damage due to sudden shock; Patented Electronically Controlled Load (ECL) for Automatic Precision Assessment (APA) and minimum weight determination; Multi user and multi level password functions.

Features

  • Impact shock detection (ISD)*1 that visualizes what degree of impact shock is detrimental to the balance and allows users to take preventive measures as necessary
  • Flow rate display (FRD)*2 that makes calculating and recording flow rates easier and more accurate
  • Auto precision assessment (APA) and minimum weight calculation using electronically controlled load (ECL)*1
  • Cushioning under the weighing pan to mitigate impact shocks
  • Protection against vertical and transverse static overloading
  • Flow rate comparator that indicates whether the flow rate is within the designated limits
  • Tare memory function that saves the tare value in non-volatile memory
  • Alert function to ensure that the measured quantity is not smaller than the set minimum weight
  • Fast stabilization of approx. 1 second (approx. 1.5 seconds with the GX/F-1603A and GX/F-10002A)
  • Selectable response characteristics for trading weighing speed for higher display stability or vice versa
  • One touch calibration using internal weight (GX-A)
  • Automatic self calibration to maintain accuracy under temperature changes (GX-A)
  • Timed calibration function (GX-A)
  • Large, front-mounted spirit level with LED illumination
  • Easy-to-adjust leveling feet with thumbwheels
  • Clearly visible, reverse backlit LCD display
  • Multiple weighing units: g, oz, lb, lb-oz, ozt, ct, mom, dwt, grain, specific gravity, and a user-programmable unit for conversion applications (either tael, tola or Newton can be added upon request)
  • User access control (UAC) function that password-protects the balance at two levels
  • Key lock function to make the balance operable only by sending commands from an external device
  • Clock and calendar function
  • GLP/GMP/GCP/ISO compliant output to meet documentation requirements
  • Universal Flexi Coms (UFC) function to edit serial data output/printout format
  • Gross/Net/Tare output
  • Data memory function to save weighing results, calibration results and unit masses for the counting mode in the device itself
  • Counting mode with the Automatic Counting Accuracy Improvement (ACAI) function
  • Percent mode function for target weighing or checking sample variation
  • Animal weighing (average & hold) function for weighing moving objects
  • Statistical calculation function (SCF) to facilitate the analysis of measurements
  • Five-level comparator function with buzzer
  • Auto power ON and OFF functions
  • Density determination function (optional density determination kit available for the 0.001 g models)
  • Underhook for weighing a magnetic material as well as measuring density
  • Security slot in the rear of the balance to accommodate an anti-theft lock

*1 Patented
*2 Patent pending

Brochures

Product brochuresGeneral Lab

Smart Super Hybrid Sensor (Smart SHS)

In the past, A&D developed a weighing sensor called the Super Hybrid Sensor (SHS) for the GX/GF series─predecessor to the newly-developed GX-A/GF-A series of multifunctional precision balances. The SHS is a sensor that combines the technology of the electromagnetic force restoration method and a spring-material Roberval structure used for load cells using strain gauges. The SHS takes advantage of both the high resolution of electromagnetic force restoration balances and the high stability of strain gauge load cell balances when loading an object on the weighing pan.

Application NoteGeneral Lab

Verification of a Method for Testing Repeatability of Electronic Balances Without Using a Weight

Recently, balances are increasingly used in unfavorable environments such as inside a fume hood or enclosure where airflow is generated. Under such circumstances, it is essential to correctly evaluate the performance of the balance at the actual location of installation, which requires calculating repeatability using a weight. However, in many fields, use of weights is a cumbersome and time-consuming operation. Solution: Load/unload the balance without using a weight by electronically controlling and altering its internal settings. In this application note, this method for evaluating the performance (repeatability) of a balance, called Electronically Controlled Loaded or ECL, is proposed and tested.


Application NoteGeneral Lab

ECL and the USP Minimum Weight Standard

ECL, which stands for Electronically Controlled Load, is A&D's unique technology (patent pending) of generating a minute load (0.3 to 3% of the balance capacity) by purposely altering the equilibrium state of the electromagnetic force restoration sensor. A balance with this technology, such as the GX-A/GF-A series, allows the user to test its repeatability performance without using an external weight by automatically calculating the standard deviation from 10 repeated measurements with the said artificially generated load. Further, based on the result of this repeatability test, the balance indicates the minimum weight
in accordance with the United States Pharmacopeia (USP) standard. Currently, ECL can complete a repeatability test and minimum weight calculation in about a minute and a half.


Product Overview

Links

Buy Multi functional range of precision top pan balances with unique features and rugged, robust design. Calibration by external weight. 220g by 0.001g Read Reviews