Spotlight 400 FTIR Imaging System
The Spotlight 400 FTIR Imaging System combines high sensitivity and rapid imaging with ease-of-use. The ability to image rapidly large sample areas at high spacial resolution (down to 10 microns) extends IR microscopy into new application areas such as the study of biomaterials such as tissue, bone, leaves etc. The Spotlight 400 can be used in the mid- or near-IR spectral ranges, as well as dual-range, depending on whether, r…

The supplier does not provide quotations for this product through SelectScience. You can search for similar products in our Product Directory.
Excellent, moderate and friendly user. Best pricing and warranty facility
Pharma education
The equipment are easy to handle and monitor. The flexibility of the model makes the interpretation easy and quick.
Review Date: 6 Feb 2026 | PerkinElmer
Awesome
Analysing functional group introduced in sample
It is a nice instrument and easy to handle.
Review Date: 12 Dec 2022 | PerkinElmer
Great results with this instrument!
Analyze microplastics in sewage sludge samples
The instrument is practical, easy to use and gives high-quality results.
Review Date: 5 Dec 2022 | PerkinElmer
A very good instrument to use for academic purposes.
Biosensing and Bioimaging
The SpotlightTM IR microscope systems gives high-quality, repeatable information from a variety of sample types in laboratory. The Spotlight 400 FT-IR Imaging System integrates ease of use with high sensitivity and quick imaging. It gives high spatial resolution imaging of vast sample regions and enables the comprehensive analysis and intelligent automation. This also enables the capture of high resolution infrared images of incredibly small samples to visualise the composition of materials based on FT-IR spectral data.
Review Date: 21 Oct 2022 | PerkinElmer
Instrument operation is good, needs to improve audit trail.
Analysis of samples in Pharmaceutical Industry
In Perkin Elmer application software's Audit trail module needs to update . Its individualized audit trail in each user login. It is suggested that it should be developed separate module in application to support 21 CFR PART 11.
Review Date: 16 Jul 2022 | PerkinElmer
Great results.
Study of polymer samples
It is easy to use.
Review Date: 15 Jul 2022 | PerkinElmer
Giving accurate and good results
For identification
The speed, accuracy, and convenience of IR spectroscopy is good
Review Date: 22 Jun 2022 | PerkinElmer
FTIR spectrum two (Perkin Elmer Life and Analytical Sciences, CT, USA)
Polymers
Easy to use powerful compact and robust Spectrum Two is the FT IR spectrometer of choice for everyone everywhere With fully integrated robust universal sampling for trouble-free measurements and portability options Spectrum Two is ideal for use in both laboratory and remote testing environments Ideally suited to everyday analysis you can confidently perform fast accurate IR analysis and assure the quality of your materials across a wide range of applications Choose the Spectrum Two that combines a powerful industrial-grade touch screen with cloud connectivity to offer you maximum productivity
Review Date: 29 Mar 2022 | PerkinElmer
The system is very versatile and easy to use. One of the best FTIR on the market
Analysis of microplastics within environmental samples
We are using this instrument for microplastic analyses. It is really easy to use as you can swich from reflexion/transmitance to ATR very quiclky.
Review Date: 29 Mar 2022 | PerkinElmer
Good results.
Polymer formulation research
Easy to use, good customer service.
Review Date: 21 May 2021 | PerkinElmer
The Spotlight 400 FTIR Imaging System combines high sensitivity and rapid imaging with ease-of-use.
The ability to image rapidly large sample areas at high spacial resolution (down to 10 microns) extends IR microscopy into new application areas such as the study of biomaterials such as tissue, bone, leaves etc.
The Spotlight 400 can be used in the mid- or near-IR spectral ranges, as well as dual-range, depending on whether, respectively, the Spectrum 100, Spectrum 100N or Spectrum 400 mid-/near- spectrometer is used.
Spotlight 400 FTIR Imaging System Features:
- Solid-state white light illumination.
- Fully-automated focus, stage movement and illumination.
- Duet™ detector design containing a single element MCT detector and a linear array MCT imaging detector.
- Very high sensitivity providing high quality data down to the accepted diffraction limits
- Rapid-scan IR imaging.
- 6.25µm, 25µm and 50µm pixel resolution to give flexibility in spacial resolution and imaging line.
- Can operate in mid-IR, near-IR or dual range to cover the full range of imaging applications in one instrument.
- Optional ATR imaging improves the spacial resolution by a factor of four, down to 3 microns at 1000 cm-1
Augmenting Standard Methods of Measuring Airborne PM<sub>2.5</sub> Using IR Imaging
This application note will demonstrate the utility and useful information that can be obtained by the use of imaging FT-IR microscopy for the cross-border study of particulate matter. The study was performed using data collected in South Korea, China and Japan.
Hair Spray on an Individual Hair Fiber
Examination of trace components on individual fibers is essential for the linkage of a victim of crime and/or a suspect to the scene of a crime. This application note describes an ATR microscopy method for the fast and easy identification of hairspray on an individual hair fiber.
ATR Imaging of Pharmaceutical Tablets
In this application note by PerkinElmer, ATR imaging measurements of commercial pharmaceutical tablets are developed. This technique shows a major advance in state of the art pharmaceutical tablet imaging. It provides an improvement in achievable spatial resolution compared with NIR chemical imaging, and sharper, generally easier to interpret images. The technique overcomes the major limitation of direct diffuse reflectance imaging in the mid-IR, namely problems with high signal attenuation and uncontrolled specular reflectance contributions in the image. It also avoids some of the limitations of Raman imaging such as sample overheating, potential fluorescence, limited spatial resolution (depending on Raman hardware configuration) and relatively long image collection times.
PerkinElmer launches innovative FT-IR platform for quality and safety testing of wine, dairy and liquid foods
The new systems include cloud based-software and streamlined workflows to deliver results in under 45 seconds