Products & ReviewLife Sciences

DRAQ7 DROP & GO

Biostatus LimitedDR72524Available: Worldwide

Ready-to-use, dropper bottle far-red viability probe

Biostatus Limited

The supplier does not provide quotations for this product through SelectScience. You can search for similar products in our  Product Directory.

Reviews

Average Rating 5.0

|1Scientists have reviewed this product

Ease of Use
After Sales Service
Value for Money
Write your own review

Extremely effective and as easy to used as described in the name: "Drop & Go"

 

Average Rating 5.0

Application Area:

Cell sorting and Cell viability assays

For many years, my core facility users in general and I, personally, have been using several BioStatus products, mainly DRAQ5 and DRAQ7. I have always found them effective and extremely easy to use. DRAQ7 has shown for many years to be a fantastic option for the detection and exclusion of dead cells. Quite recently, we have tested and used DRAQ7 DROP & GO for the detection and exclusion of dead cells from a very heterogeneous sample for isolating photoreceptors from adult zebrafish retinae for downstream RT-PCR. It was as easy as described in the name of the product "drop and go". Dead cells were clearly differentiated from the alive ones as can be easily observed in our recently published paper Glaviano et al. "A method for isolation of cone photoreceptors from adult zebrafish retinae" BMC Neuroscience (2016) 17: 71 (DOI 10.1186/s12868-016-0307-2)

Review Date: 23 Nov 2016 | Biostatus Limited

DROP & GO™ is a NEW, ready to use formulation of DRAQ7™ - the far-red/NIR fluorescent DNA dye that ONLY stains nuclei of DEAD / permeabilised cells (even in long-term assays)

Application NoteLife Sciences

DRAQ7 in Cell Health Assays

One of the biggest costs in drug discovery and development has been failures of drug candidates after launch, due to unexpected or idiosyncratic toxicity. In this application note, learn how the DNA-binding viability probe, DRAQ7, is used in image-based and FC-based cell health assays to determine dead or dying cells.


White PapersLife Sciences

Application of DRAQ™ Dyes in Single Cell Transcriptomics and Genomics

DRAQ5™ and DRAQ7™ dyes provide accurate fluorescent labelling and assist in distinguishing cell status for single cell transcriptomics and genomic applications. One concern regarding the use of these DNA binding dyes is any unwanted effects on the first strand cDNA synthesis. However, studies in this white paper have demonstrated that DRAQ5™ and DRAQ7™ do not interfere with the synthesis process, indicating an accurate experimental outcome.


Scientific PosterLife Sciences

Channel- & Compensation-free Dead Cell Exclusion: N+1 Panel Design

Dead cell exclusion is a common requirement for flow cytometry using viability dyes like DAPI, PI and 7-AAD. Anew far-red fluorescing alternative DRAQ7™ has been robustly tested showing improved separation between negative and positive events. Conventional flow cytometry is limited by spectral "space" and the preference for bright chromophores to label antibodies to aid sensitivity that increases channel spillover. At its simplest, far-red DRAQ7 can benefit panel design where, for example, the complete absence of spillover into the FITC and R-PE detectors makes it an obvious replacement for 7-AAD in CD34+ cell enumeration.