AZURA® Analytical HPLC
Analytical HPLC

The supplier does not provide quotations for this product through SelectScience. You can search for similar products in our Product Directory.
great result
analyze of cafeine, vitamin, carbohydrate, etc.
The effectiveness of the product in the analysis is very good, the service from the manufacturer is also good with fast response and the right solution to problems that arise in the use of the tool. High level of accuracy of the analysis results with good reproduction results. Tools are very easy to operate, The price of the tool is relatively affordable, however, the results provided are good.
Review Date: 21 Dec 2022 | KNAUER Wissenschaftliche Geräte GmbH
The analytical HPLC and UHPLC systems of the KNAUER AZURA liquid chromatography instruments are designed to support and facilitate your work. Whether doing routine analysis or demanding separation tasks, AZURA systems are the right tool to overcome your analytical challenges. Choose between different gradient forming technologies and maximum flow rates to find the best configuration for your task.AZURA® Analytical comprises a large variety of different modules which enable you to choose the configuration you require for your analytical task. Choose from different pumps, gradient systems, and detectors.
AZURA Compact with max. backpressure of up to 400 bar represents a very cost-effective HPLC system for basic applications.
AZURA HPLC Plus systems with extended backpressure up tp 700 bar are ideal for improved routine separation tasks.
AZURA UHPLC systems systems provide an extended backpressure range of 1000 bar and an optimized dwell volume. These systems are made for high demanding separation tasks and high throughput applications.
AZURA Analytical HPLC/UHPLC features:
• Isocratic, binary high pressure gradient or quaternary low pressure gradient pump
• Pump heads allowing flow rates up to 10 ml/min at 700 bar or 1000 bar up to 2 ml/min
• Autosampler with 0.1 μl sample aspiration at max. 1200 bar with zero sample loss
• Choice of highly sensitive UVD, MWD, DAD, or RID detectors with intelligent temperature control
• Wide range of flow cells available, including remote cells
• Finger-tight high pressure stainless steel capillary connections “K-Connect”
• Extensive safety features such as leak management and sensors
• Frontal access of detector lamp and pump head for easy maintenance
Verification of Mycotoxin Patulin from Apple Juice with Isocratic HPLC
The permitted daily exposure for the mycotoxin patulin is 0.05 µg/mL in apple juice, as stated by the Scientific Committee on Food for the European Commission. In this application note, KNAUER presents a fast protocol for the determination of patulin from apple juice using the AZURA® HPLC plus with a Eurospher II column.
Scale-Up of an Analytical HPLC Method for Steviol Glycosides to a Preparative Approach
In this application note, KNAUER describes how an existing analytical HPLC method can be transformed to a preparative HPLC using the KNAUER Scale-Up Converter. The example used in this application is steviol glycosides, which are often used as natural sugar substitutes due to a far higher sweetening power than normal sucrose or glucose. However, this approach is also designed to be applicable for the fast scale-up of other analytes.
Quantification of Steviol Glycosides in Stevia Samples with RP-HPLC
In this application note, KNAUER provides a method that promises fast determination of six steviol glycosides. The AZURA® HPLC plus system is designed for fast separation in under ten minutes and an optimized gradient, promising fast quality control of Stevia products.
Determination of Vanillin and Associated Marker Substances
With the continuous increase in the price of vanilla pods, artificial vanilla flavoring agents such as vanillin are in high demand. In this application note, KNAUER outlines a method using the AZURA® UHPLC system for screening the components of different vanilla products to determine authenticity.
Quantitative Determination of Primary Aromatic Amines in Recycled Cold-Cure and Flexible Foams
A reliable method for the quantification of aryl amines in cold-cure and flexible foams from recycled mattresses is described in the following application. The focus was set on two substances, 2,4-diaminotoluene (TDA) and 4,4-diaminodiphenylmethane (DAPM), which are mandatory to be determined before processing the recycled foam due to their carcinogenic properties.
Alternative Xylitol Extraction via HPLC Purification from Fermented Biomass
A latest approach in bioethanol generation is the usage of yeast and bacteria that uses C5 sugars for fermentation and the valorization of bio refinery by products. Here it is shown that a hemicellulose-like fermentation mash has a high content of the artificial sweetener xylitol and that its purification by HPLC can be accomplished using polymer based Eurokat columns. The product is soluble in water and can easily be used for further applications.
Features of the AZURA Analytical HPLC and UHPLC Systems
This video introduces the AZURA Analytical HPLC and UHPLC systems from Knauer. The AZURA systems are designed to support and facilitate your analytical work. The systems are modular so can be designed to suit your laboratory’s needs and the detectors can easily be upgraded. The video describes the systems features which include precise temperature control, highly sensitive multiwavelength detectors and Polka Dot technology, which enables maximum light intensity and low noise.
Advances in Purification Technology for Diverse Applications
Learn about the versatile AZURA® Prep LC platform from KNAUER, which can be used for the purification of fine chemicals, active ingredients, reactants, and many more. The systems feature a maximum flow rate of up to 1000 ml/min, different gradient options, a choice of sample feed and fractionation options as well as selectable purification software packages. Visit www.knauer.net/azurapreplc for more information.
LABOMATIC Instruments AG and KNAUER Wissenschaftliche Geräte GmbH enter into strategic cooperation
Both companies serve end users, sales partners, and original equipment manufacturer (OEM) customers
KNAUER HPLCs ACT Ecolabel certified
Environmental impact of KNAUER's HPLC systems evaluated by My Green Lab with assignment of ACT Ecolabel
Top tips and future perspectives in cannabis testing from industry experts
SelectScience speaks with two KNAUER scientists working to innovate quality testing solutions for the rapidly-changing cannabis industry, with a glimpse into their approach for 2020
Networking for progress in bio-process analytics
The Bio-PAT network for SMEs and research institutions aims to establish cooperation to accelerate bio-processes technology development
Chromatography industry meeting of the Berlin Brandenburg region was a great success
Technology visionaries and laboratory experts met for a regional chromatography industry meeting in Berlin Zehlendorf to discuss opportunities and challenges of this analytical laboratory technology
KNAUER Presents Latest Liquid Chromatography Systems at ACHEMA 2018
Berlin-based manufacturer of liquid chromatography equipment, KNAUER, will be showcasing its latest systems and devices at ACHEMA
Winner Announced for VICTRESS Succession Award 2018
Alexandra Knauer from KNAUER Wissenschaftliche Geräte swoops the award with her excellency in leadership and entrepreneurship
Curiosity and Customers are the Keys to Knauer Success
Meet the entrepreneur at the helm of the family-friendly scientific instruments manufacturer


































