Spectrum™ Spectra/Por™ 1 RC Dialysis Membrane Tubing 6000 to 8000 Dalton MWCO by Thermo Fisher Scientific

2.0
/
5.0
  |  1 reviews
Ideal for molecular separation, protein binding studies, electrolyte removal, desalting.


Spectrum™ Spectra/Por™ 1 RC Dialysis Membrane Tubing 6000 to 8000 Dalton MWCO by Thermo Fisher Scientific product image
Spectrum™ Spectra/Por™ 1 RC Dialysis Membrane Tubing 6000 to 8000 Dalton MWCO

The supplier does not provide quotations for this particular product through SelectScience. You can search for similar products in our product directory.




Average Rating: 2.0
1 Scientist has reviewed this product

1 out of 5
Ease of use
3 out of 5
After sales service
2 out of 5
Value for money


  • Status:

    Expert Reviewer
  • Member since: 2016

  • Organization: Eastern Virginia Medical School



  • Ease of use
    1 out of 5
    After sales service
    3 out of 5
    Value for money
    2 out of 5
Share this Review on LinkedinShare this Review on TwitterShare this Review on Facebook
Product works but not easy
Rating: 2.0

  • Application Area: Buffer exchange

"This regenerated cellulose dialysis tubing (MWCO 6000-8000) can be difficult to use. I would suggest the chambers over the tubing. The product did perform its function. It was just not easy to use."

Review date: 02 Feb 2017 | Spectrum™ Spectra/Por™ 1 RC Dialysis Membrane Tubing 6000 to 8000 Dalton MWCO

Supplied as flat-width tubing or flat sheets that can be folded to fit various funnel-type dialysis apparatus. Pure regenerated natural cellulose membranes with 1000 to 50,000 molecular weight cutoffs.

  • Transparent and flexible
  • Low molecular weight compounds in aqueous solutions diffuse through membrane
  • Higher molecular weights, such as proteins and bacteria, are retained by membrane
  • Glycerol preserves membrane and must be removed before use
  • Flat sheets and discs available for use with dialysis apparatus

Do not tie knots in tubing; use closures

Specification

  • Material: Regenerated Cellulose
  • Quantity: Each
  • Formulation: Contain glycerin as a humectant
  • For Use With (Application): Ideal for molecular separation, protein binding studies, electrolyte removal, desalting
  • MWCO: 6000 to 8000 d
  • Temperature Range (Metric): 4° to 121°C

Product Overview

Spectrum™ Spectra/Por™ 1 RC Dialysis Membrane Tubing 6000 to 8000 Dalton MWCO by Thermo Fisher Scientific product image

Spectrum™ Spectra/Por™ 1 RC Dialysis Membrane Tubing 6000 to 8000 Dalton MWCO

Manufacturer Thermo Fisher Scientific

2.0 / 5.0 | 1 reviews