ShinCarbon ST Columns by Restek Corp.

Manufacturer Restek Corp.
4.8
/
5.0
  |  3 reviews
SilcoSmooth Stainless Steel Separate permanent gases, including carbon monoxide and carbon dioxide, without cryogenic cooling. Rapid separations of permanent gas/light hydrocarbon mixtures. Excellent compatibility with most GC detectors—minimal bleed, minimal baseline rise. Preconditioned, less than 30 minutes to stabilize. Maximum temperature of 280 °C/300 °C.


ShinCarbon ST Columns by Restek Corp. product image
ShinCarbon ST Columns
Request Pricing

Receive your quote directly from the manufacturer.




Average Rating: 4.8
3 Scientists have reviewed this product

5 out of 5
Ease of use
5 out of 5
After sales service
5 out of 5
Value for money


  • Status:

    Reviewer
  • Member since: 2018

  • Organization: ErreDue SpA



  • Ease of use
    5 out of 5
    After sales service
    4 out of 5
    Value for money
    4 out of 5
Share this Review on LinkedinShare this Review on TwitterShare this Review on Facebook
HC detection!
Rating: 4.3

  • Application Area: Analysis of natural gas

"Great resolution and low DL! Even at 21°C, with a BID detector in a GC-2010 Plus, I could detect 1.8ppm of methane. While it's a little bit deteriorated now (3yrs of using), it's really helpful for monitoring the concentration of hydrocarbons."

Review date: 02 Dec 2019 | ShinCarbon ST Columns
  • Status:

    Reviewer

  • Member since: 2019

  • Organization: University of Oxford



  • Ease of use
    5 out of 5
    After sales service
    5 out of 5
    Value for money
    5 out of 5
Share this ReviewShare this Review on TwitterShare this Review
Produce great and reliable results
Rating: 5.0

  • Application Area:Analyse gas composition in biogas

"The column was easy to install and set up. I have used this column to analyse gas composition in biogas for over a year and the column still works well. The peaks are prominently sharp."

Review date: 17 Apr 2019 | ShinCarbon ST Columns
  • Status:

    Reviewer

  • Member since: 2019

  • Organization: University of Liverpool



  • Ease of use
    5 out of 5
    After sales service
    5 out of 5
    Value for money
    5 out of 5
Share this ReviewShare this Review on TwitterShare this Review
Great.
Rating: 5.0

  • Application Area:GC measurement

"This column is very easy to use and we already bought twice. It can separate H2, CO, CH4 and CO2."

Review date: 12 Apr 2019 | ShinCarbon ST Columns

SilcoSmooth Stainless Steel

  • Separate permanent gases, including carbon monoxide and carbon dioxide, without cryogenic cooling.

  • Rapid separations of permanent gas/light hydrocarbon mixtures.

  • Excellent compatibility with most GC detectors—minimal bleed, minimal baseline rise.

  • Preconditioned, less than 30 minutes to stabilize.

  • Maximum temperature of 280 °C/300 °C.

Product Overview

ShinCarbon ST Columns by Restek Corp. product image

ShinCarbon ST Columns

Manufacturer Restek Corp.

4.8 / 5.0 | 3 reviews