Human Inflammation Array Q3 by RayBiotech Inc.

Manufacturer RayBiotech Inc.  |   Model: QAH-INF-3
Quantibody® Human Inflammation Array 3 Kit. Detects 40 Human Inflammatory Factors. Suitable for all liquid sample types.


Human Inflammation Array Q3 by RayBiotech Inc. product image
Human Inflammation Array Q3

The supplier does not provide quotations for this particular product through SelectScience. You can search for similar products in our product directory.



0 Scientists have reviewed this product


Write the First Review

No Reviews

Product Features

  • More cost-effective than traditional ELISA
  • High specificity and system reproducibility
  • Suitable for diverse sample types
  • Low sample volume requirement: 50 µL or less
  • Get results same day (6-hour processing time)
  • Well-suited for high throughput assays
  • Q Analyzer software provides one-step computation

Species Detected

Human

Application Notes

Suggested Application
Multiplexed Protein Detection; Biomarker Screening; Identifying Key Factors; Confirming Biological Process; Biomarker Validation; Validation of Antibody Array Results; Quantitative Protein Detection; Establishing Normal Range
Kit Components
  • Human Inflammation Array Q3 Slide(s)
  • Blocking Buffer
  • Wash Buffer 1
  • Wash Buffer 2
  • Lyophilized Standard Mix
  • Biotinylated Detection Antibody Cocktail
  • Streptavidin-Conjugated Fluor
  • 30 ml Centrifuge Tube
  • Adhesive Plastic Strips
  • Manual
Other Materials Required
  • Distilled or deionized water
  • Small plastic boxes or containers
  • Pipettors, pipette tips and other common lab consumables
  • Orbital shaker or oscillating rocker
  • Aluminum foil
  • Gene microarray scanner or similar laser fluorescence scanner
Protocol Outline
  1. Dry the glass slide
  2. Prepare Standards
  3. Block array surface
  4. Incubate with Samples and Standards
  5. Incubate with Biotinylated Detection Antibody Cocktail
  6. Incubate with Streptavidin-Conjugated Fluor
  7. Disassemble the glass slide
  8. Scan with a gene microarray laser scanner
  9. Perform densitometry and analysis

Storage/Stability

For best results, store the entire kit frozen at -20°C upon arrival. Stored frozen, the kit will be stable for at least 6 months which is the duration of the product warranty period. Once thawed, store array slide(s), standard mix, detection antibody cocktail, and Cy3-Conjugated Streptavidin at -20°C and all other reagents undiluted at 4°C for no more than 3 months.

Number of Targets Detected

40

Product Overview

Human Inflammation Array Q3 by RayBiotech Inc. product image

Human Inflammation Array Q3

Manufacturer RayBiotech Inc.

Be the first to review this product