Rtx-5 (G27) Columns (Fused Silica) by Restek Corp.

Manufacturer Restek Corp.  |   Model: 10253
5.0
/
5.0
  |  3 reviews
Low-polarity phase; Crossbond diphenyl dimethyl polysiloxane General-purpose columns for drugs, solvent impurities, pesticides, hydrocarbons, PCB congeners (e.g., Aroclor mixes), essential oils, semivolatiles. Equivalent to USP G27 and G36 phases. Temp. Limits: -60 to 325/340 °C Similar To: Agilent 122-5033, 19091J-233; Phenomenex 7HG-G002-22; Varian CP8771; Grace 13657, 5121840, 8635223 Length: 30 m Internal Diameter: 0.25 mm df (µm): ... Read more


Rtx-5 (G27) Columns (Fused Silica) by Restek Corp. product image
Rtx-5 (G27) Columns (Fused Silica)
Request Pricing

Receive your quote directly from the manufacturer.




Average Rating: 5.0
3 Scientists have reviewed this product

5 out of 5
Ease of use
5 out of 5
After sales service
5 out of 5
Value for money


  • Status:

    Reviewer
  • Member since: 2019

  • Organization: BMS



  • Ease of use
    5 out of 5
    After sales service
    5 out of 5
    Value for money
    5 out of 5
Share this Review on LinkedinShare this Review on TwitterShare this Review on Facebook
Great column.
Rating: 5.0

  • Application Area: Pharmaceuticals

"This is a very reliable column. After repeated uses and injections we get the same consistent results."

Review date: 09 Dec 2019 | Rtx-5 (G27) Columns (Fused Silica)
  • Status:

    Reviewer

  • Member since: 2018

  • Organization: Tucson Police Department



  • Ease of use
    5 out of 5
    After sales service
    5 out of 5
    Value for money
    5 out of 5
Share this ReviewShare this Review on TwitterShare this Review
Great column, great service!
Rating: 5.0

  • Application Area:Forensic seized drug analyses

"This column is almost perfect for seized drug analyses. Secondary amines (such as methamphetamine and MDMA) need to be base extracted for that nice, narrow peak, and d9-THC likes to hang around, but otherwise I am very satisfied with this column. The customer service at Restek has also been great!"

Review date: 31 Jul 2018 | Rtx-5 (G27) Columns (Fused Silica)
  • Status:

    Reviewer

  • Member since: 2018

  • Organization: Suffolk County Water Authority



  • Ease of use
    5 out of 5
    After sales service
    5 out of 5
    Value for money
    5 out of 5
Share this ReviewShare this Review on TwitterShare this Review
Great results.
Rating: 5.0

  • Application Area:Drinking Water - Herbacides/Pesticides

"We've used these columns for years and they are superior to other vendors. They are always shipped out to us in a timely manner and we can always count on their reproducibility. We test at or below NYS drinking water quality standards and these columns always deliver."

Review date: 27 Jul 2018 | Rtx-5 (G27) Columns (Fused Silica)

Low-polarity phase; Crossbond diphenyl dimethyl polysiloxane

  • General-purpose columns for drugs, solvent impurities, pesticides, hydrocarbons, PCB congeners (e.g., Aroclor mixes), essential oils, semivolatiles.
  • Equivalent to USP G27 and G36 phases.


Temp. Limits:

  • -60 to 325/340 °C

Similar To:

  • Agilent 122-5033, 19091J-233; Phenomenex 7HG-G002-22; Varian CP8771; Grace 13657, 5121840, 8635223

Length:

  • 30 m

Internal Diameter:

  • 0.25 mm

df (µm):

  • 1.00 μm

Product Overview

Rtx-5 (G27) Columns (Fused Silica) by Restek Corp. product image

Rtx-5 (G27) Columns (Fused Silica)

Manufacturer Restek Corp.

5.0 / 5.0 | 3 reviews