AIA-360 Analyser by Tosoh Bioscience

Manufacturer Tosoh Bioscience
4.1
/
5.0
  |  6 reviews
Bench top Immunoassay Analyser. Offers the automation powers and performance of a large analyser in a bench top format. Random access allows any combination of tests, in any order at any time and a throughput of 36 results per hour with the first result in 20 minutes ensures a fast reliable service.AIA-360 Analyser Features: Will accept a variety of primary tubes with positive patient identification as well as positive test cup ID to eliminate errors. Sample level sensing, to alert operat... Read more


AIA-360 Analyser by Tosoh Bioscience product image
AIA-360 Analyser
Request Pricing

Receive your quote directly from the manufacturer.




Average Rating: 4.1
6 Scientists have reviewed this product

4 out of 5
Ease of use
4 out of 5
After sales service
4 out of 5
Value for money


  • Status:

    Reviewer
  • Member since: 2020

  • Organization: Plc



  • Ease of use
    5 out of 5
    After sales service
    5 out of 5
    Value for money
    5 out of 5
Share this Review on LinkedinShare this Review on TwitterShare this Review on Facebook
I swear by this instrument, never fails.
Rating: 5.0

  • Application Area: Immunoassay

"Small instrument suited for a small lab, minimal maintenance, customer support is the best."

Review date: 23 Jul 2020 | AIA-360 Analyser
  • Status:

    Reviewer

  • Member since: 2019

  • Organization: Bronson Methodist Hospital



  • Ease of use
    5 out of 5
    After sales service
    5 out of 5
    Value for money
    5 out of 5
Share this ReviewShare this Review on TwitterShare this Review
Good choice for POCT iPTH.
Rating: 5.0

  • Application Area:Intraoperative parathyroid

"The AIA 360 is one of the few methods available for performing parathyroid testing intraoperatively at the point of care. Although it is moderately complex our nursing staff find it reliable and easy to use. The run time of 20 minutes is comparable with a stat assay in the main laboratory. Although POC will never be as cost effective as a laboratory assay the TOSOH keeps our surgeons happy."

Review date: 18 Jun 2019 | AIA-360 Analyser
  • Status:

    Reviewer

  • Member since: 2019

  • Organization: Eastbay fertility



  • Ease of use
    3 out of 5
    After sales service
    1 out of 5
    Value for money
    1 out of 5
Share this ReviewShare this Review on TwitterShare this Review
Poor customer service, they just want their money, you're on your own after that.
Rating: 1.7

  • Application Area:In office same day Hormone testing

"I would never get this machine again, the controls and dry reagents are too expensive as is the machine per month, poor customer service, takes a long time for them to get back to us if we have problems or issues. We are locked in a contract that will not allow us to return the machine and it is costing us a fortune just sitting there. Couldn't afford to continue using this machine. When calibrations are off, no one to talk to, we get passed from one part of the company to another when we call in."

Review date: 26 Feb 2019 | AIA-360 Analyser
  • Status:

    Reviewer

  • Member since: 2014

  • Organization: Freedom Medical Clinic



  • Ease of use
    5 out of 5
    After sales service
    5 out of 5
    Value for money
    5 out of 5
Share this ReviewShare this Review on TwitterShare this Review
Rating: 5.0
"We are a small POL that does our T4, TSH and PSA on the Tosoh AIA-360. Not only is it a very user-friendly analyzer, it has also proved economical for us. The instrument runs on individual test cups which mean no waste of reagents. Calibrations are good for 3 months unless there is a lot number change. All in all, a tough little work-horse. We have been extremely satisfied "

Review date: 23 Jan 2015 | AIA-360 Analyser
  • Status:

    Advanced Reviewer

  • Member since: 2014

  • Organization: Winchester, Patton & Burgess



  • Ease of use
    3 out of 5
    After sales service
    4 out of 5
    Value for money
    3 out of 5
Share this ReviewShare this Review on TwitterShare this Review
Rating: 3.3

  • Application Area:Immunoassay and Cardiac Markers

"The TOSOH AIA360 is relatively easy to use. Loading specimens and Reagent cups is a breeze. You must remember to add a specimen number or it will run it as, for example “Sample 1, sample 2,” etc."

Review date: 17 Dec 2014 | AIA-360 Analyser
  • Status:

    Expert Reviewer

  • Member since: 2013

  • Organization: PP klinika Kladno



  • Ease of use
    4 out of 5
    After sales service
    5 out of 5
    Value for money
    4 out of 5
Share this ReviewShare this Review on TwitterShare this Review
Rating: 4.3

  • Application Area:Biochemistry

"This instrument is suitable for smaller laboratories for acute and routine testing. We use it for 5 years it fits for different workloads from 1 stat sample with different parameters till small series e.g. thyroid examinations, or just use it for special test to fill the gap in laboratory portfolio. It may also serve as backup for bigger analysers. It was not necessary ask for company service during the use of this instrument."

Review date: 14 Mar 2014 | AIA-360 Analyser
Bench top Immunoassay Analyser.

Offers the automation powers and performance of a large analyser in a bench top format. Random access allows any combination of tests, in any order at any time and a throughput of 36 results per hour with the first result in 20 minutes ensures a fast reliable service.


AIA-360 Analyser Features:

  • Will accept a variety of primary tubes with positive patient identification as well as positive test cup ID to eliminate errors.
  • Sample level sensing, to alert operator to short samples
  • Dual clot detection to maintain result integrity
  • Extremely simple operation
  • Unidirectional interface
  • Just 40 x 40 x 50cm and 30kg
  • Results are consistent and interchangeable between other Tosoh AIA analysers

Product Overview

AIA-360 Analyser by Tosoh Bioscience product image

AIA-360 Analyser

Manufacturer Tosoh Bioscience

4.1 / 5.0 | 6 reviews