Products & ReviewLife Sciences

Infinite M Plex

The Infinite M Plex, a fully-loaded multimode plate reader with monochromator-based optics, offers free wavelength selection and scanning capabilities. Your ready-to-go workhorse for all standard absorbance, fluorescence and luminescence assays. The Infinite M Plex is one of six new tailored reader configurations based on the acclaimed Infinite 200® PRO, designed to simplify your target applications and fit your needs and bud…

Request Pricing
Tecan

Receive your quote directly from the manufacturer.

Reviews

Average Rating 4.4

|8Scientists have reviewed this product

Ease of Use
After Sales Service
Value for Money
Write your own review

Great

 

Average Rating 5.0

Application Area:

mitochondrial function

Easy to use. good after sales care. a multifunctional machine. greatest efficiency

Review Date: 15 Jun 2017 | Tecan

A very essential instrument for the lab.

 

Average Rating 4.7

Application Area:

luciferase assay, fluorescence detection, BCA assay

This is a plate reader that really easy to use with straightforward software. Can be easily upgrade for higher throughput operation. Instrument is relatively stable.

Review Date: 13 Apr 2017 | Tecan

Worthwhile the price

 

Average Rating 4.0

Application Area:

Biomedical research

It's quite easy to use; it's a multimodal plate reader that allows reading multisized plates. Besides, it's upgradeable, and it allows data exportation to Microsoft Excel. It's not a cheap equipment, but it's worthwhile the price.

Review Date: 24 Nov 2015 | Tecan

I would highly recommend it for a variety of applications

 

Average Rating 4.3

Application Area:

BCA Assays and MycoAlert Assays

This microplate reader was more than enough for our chemiluminescent assay needs. The UI was extremely intuitive and I would highly recommend it for a variety of applications (i.e. absorbance, fluorescence, chemiluminescence, etc.). We really haven't needed much after sales care but the value for the money definitely seems well worth it.

Review Date: 24 Nov 2015 | Tecan

Average Rating 4.3

Application Area:

Oncology Research

We use this product for chemiluminescent detection including MycoAlert, luciferase based assays, and BCA protein assays. It has always yielded high quality results on a consistent basis. I would highly recommend it to others. The UI is very intuitive and the reader covers the spectrum of basic to advanced readouts.

Review Date: 14 Oct 2015 | Tecan

Average Rating 4.0

Application Area:

Versatile Plate Reader

We use our Tecan plate reader for various applications from crystal violet OD to luciferase assays and even time course studies using the injector. We've had some issues now and then but overall it is a great device and a staple for our business.

Review Date: 18 Jul 2014 | Tecan

Average Rating 4.0

Application Area:

Graduate Research

We use this device extensively in the lab along with a Tecan plate washer. The Infinite Pro is a wonderful piece of lab equipment, easy to use and very reliable.

Review Date: 4 Sept 2013 | Tecan

Average Rating 5.0

Application Area:

fluorescence, luminescence, absorbance

This instrument is extremely useful in a biomedical research environment. Our lab uses it for chemiluminescence and absorbance ELISAs. Lag times can be set for time-resolved fluorescence or phosphorescence measurements which is particularly useful. It is very easy and quick to measure excitation and emission spectra for fluorescent compounds, as well as taking absorbance spectra measurements. Kinetic cycles allow you to measure luminescence decay curves.

Review Date: 3 Sept 2013 | Tecan

The Infinite M Plex, a fully-loaded multimode plate reader with monochromator-based optics, offers free wavelength selection and scanning capabilities. Your ready-to-go workhorse for all standard absorbance, fluorescence and luminescence assays.

The Infinite M Plex is one of six new tailored reader configurations based on the acclaimed Infinite 200® PRO, designed to simplify your target applications and fit your needs and budget perfectly.

Application NoteLife Sciences

Detection of Human Immunoglobulin G (IgG) Using the Infinite F200 PRO’s New AlphaLISA Function

AlphaLISA is a homogeneous, no-wash alternative to conventional ELISAs based on PerkinElmer’s bead-based Alpha (Amplified Luminescent Proximity Homogeneous Assay) technology. AlphaLISA assays can be set up as sandwich or competitive immunoassays to detect and quantify molecules of interest in biological samples. AlphaLISA assays are less prone to signal interference at wavelengths of <600 nm and the use of dedicated AlphaLISA optics permits the analysis of target molecules in blood and serum by drastically reducing the effect of hemoglobin within a sample. This application note describes the implementation of the AlphaLISA technology onto the Infinite F200 PRO, and describes the use of the reader for the detection of human immunoglobulin G (IgG) using PerkinElmer’s AlphaLISA Human IgG Assay Kit.


Case StudyLife Sciences

Tecan’s Infinite® F200 PRO with AlphaScreen® Module

Tecan developed an AlphaScreen® module for its popular Infinite® F200 PRO multimode reader which can provide customers with a cost-effective solution for AlphaScreen and AlphaLISA® assays. This application note describes the successful implementation of the Alpha technology onto the Infinite F200 PRO and summarizes the performance of the instrument with regard to measurement sensitivity, uniformity and typical reading times.


Application NoteLife Sciences

Automated Growth Monitoring of Microaerophilic Organisms in the Infinite® 200 PRO Reader with Gas Control Module

Growth analysis of micro-organisms is a fundamental part of many research areas yet can be highly time consuming and labor-intensive. Tecan have designed the Gas Control Module in conjunction with the Infinite 200 Pro Reader which allows walk-away growth monitoring through the controlled measurement chamber which provides all essential growth conditions, eliminating the need for transfer between incubators and readers and manual intervention. This application note describes the use of these systems in the analysis of growth of the human pathogen and class-I carcinogen, Helicobacter pylori, over a 28 hour period.


Application NoteSpectroscopy

Using Dedicated Detectors for Luminescent Signals; Photon-Counting Tube-based Infinite® M200 PRO with Photomultiplier Tube-based Multimode Readers

The Infinite 200 PRO is a user-friendly and affordable multimode reader, designed to cater for the needs of today’s applications. Providing a full range of leading detection methods in one easy-to-use modular instrument, multimode microplate readers (MMRs) are commonly equipped with photomultiplier tubes (PMTs) which are extremely sensitive detectors of light in the ultraviolet, visible and near-infrared ranges of the electromagnetic spectrum. This application note compares luminescence measurements using the Infinite M200 PRO with Photomultiplier Tube-based multimode readers.


Application NoteSpectroscopy

UV-Vis Spectrophotometry: Comparing Absorbance Measurements Between the Quad4 Monochromators-based Infinite® M200 PRO and a Multimode Reader using Photodiode Array Technology

The most widely established technology for UV-Vis absorbance measurement is a monochromator-based microplate reader. Tecan’s Infinite M200 PRO is a user-friendly and affordable multimode reader, designed to cater for the needs of today’s applications, providing a full range of leading detection methods in one easy-to-use modular instrument with Quad4 monochromator™. This application note compares the Infinite M200 PRO with a multimode reader using photodiode array technology on their dynamic measurement range, OD linearity in the visible and the UV range and measurement reproducibility.


Application NoteLife Sciences

Improved Cell Viability Assay Performance using PrestoBlue® Cell Viability Reagent alongside Infinite M200 PRO and Infinite M1000 PRO Multimode Microplate Readers

Assessment of cellular viability markers in cell-based applications is mandatory for laboratories working with in vitro systems. Life Technologies offers an enhanced version of the commonly available resazurin-based assays, the PrestoBlue® Cell Viability Reagent. This application note describes the evaluation of Life Technologies’ PrestoBlue® Cell Viability Reagent using the Infinite M200 PRO and the Infinite M1000 PRO multimode microplate readers.


Application NoteFood and Beverage

ORAC Assay for the Determination of Antioxidant Capacity in Foods using the Infinite® 200 PRO Multimode Reader

Reactive oxygen species (ROS) are generated as natural by-products of the cellular metabolism. They are involved in various biological processes, functioning as important signal mediators. However, excess intracellular levels of ROS may result in cell and tissue damage, and are associated with degenerative diseases, most notably cancer. A well-established and reliable method to determine the antioxidant capacity of a substance is the oxygen radical absorbance capacity (ORAC) assay. This application note describes the use of the Infinite® F200 PRO in combination with a commercially available ORAC assay kit, using different beverages as antioxidant samples.


Application NoteLife Sciences

Long-term Cell-based Kinetics using Tecan’s GCM™ and the Thermo Scientific Nunc Edge Plate

This application note describes the capability of Tecan’s Infinite® 200 PRO multimode reader to regulate the CO2 partial pressure inside its measurement chamber. The investigation of biological processes requires time-dependent analysis of cellular signals, from several hours up to several days. However, long-term studies with living eukaryotic cells can only be performed for a limited time inside common microplate readers.



Application NoteSeparations

Extractables do not Affect Downstream Vitamin D Analysis by LC-MS/MS when Using the Tecan AC Extraction Plate™

Quantification of small molecules in biological samples (such as serum, plasma, urine or blood) by LC-MS is generally only performed after a sample clean-up step. This is due to the presence of specific matrix constituents – such as proteins and phospholipids – which might negatively affect the analysis. The Tecan AC Extraction Plate simplifies sample preparation by efficiently removing most matrix components – such as proteins and salts – without any precipitation, filtration, centrifugation and evaporation steps.


Product Overview

Links