iCELLis™ Nano+ bioreactor system
CytivaThe iCELLis™ Nano+ system for process development and small-scale production (up to 4 m²)
The iCELLis™ Nano+ system for process development and small-scale production (up to 4 m²)
The iCELLis™ 500+ system for industrial scale manufacturing (up to 500 m²)
Mustang™ membrane chromatography capsules, a Pall Life Sciences product, are robust, easy to use and enable users to significantly optimize their process by minimizing buffer consumption, increasing throughput and reducing capital expenditure.
The ReadyToProcess WAVE 25 rocker features integrated temperature sensors and load cells, designed for convenient handling and control of cell cultures up to 25 L. A filter heater is delivered with the system.
The Xuri Cell Expansion System W25 delivers an automated, controlled expansion environment for the growth of cell therapies in volumes up to 25 L across research, process development, and manufacturing operations.
The VIA Freeze range of controlled-rate freezers are liquid nitrogen-free. They combine customizable freezing profiles, electronic control systems, and a conduction cooling method to optimize GMP-compliant cryopreservation.
The Sepax C-Pro Cell Processing System, which is comprised of the instrument, Sepax C-Pro protocol software, and kits, allows you to combine multiple processing steps in a versatile manner. These steps include but are not limited to enrichment, magnetic bead incubation, spinoculation, concentration, washing, dilution, and splitting.
Hipersep® Prochrom columns have been designed to run for decades without any loss of performance. This performance consistency over time is enabled by Dynamic Axial Compression (DAC) technology. Our columns are engineered for ease of cleaning and maintenance operations while maximizing operator safety.
The HALO ® PCS C18 is a positively charged surface chemistry designed to deliver improved peak shapes for basic compounds.
Packed in PEEK Suitable for anionic substances (especially phosphate compounds) analysis using HILIC mode Use of some eluents add ion exchange mode Polymer-based packing material provides excellent chemical stability and minimum deterioration over an extended time period Suitable for LC/MS analysis
YMC-Triart columns are well-suited to a variety of applications in pharmaceutical and chemical laboratories. Eight different phases are available, all trifunctionally bonded, in column sizes ranging from .075 – 300mm ID.
Intuitive PowerStream chromatography software provides for 21 CFR part 11 compliance.
Compact column heater/chiller with large internal spaces. Use with Cecil or third party LC systems.
Includes a single binary or quaternary low pressure mixing pump.
The TSKgel ODS-100 HPLC column features a newly developed RP material for the separation of small compounds which is specifically designed to simplify difficult separations.
From KNAUER, Simulated Moving Bed - The Next Step in Chromatography! Preparative chromatography (Simulated Moving Bed) is increasingly applied as a separation technique in the pharmaceutical industry, production of fine chemicals, and in the field of bioengineering. Why Simulated Moving Bed? Simulated Moving Bed is a method in process chromatography that enables substance mixtures to be continuously separated and extracted in…
This four channel degasser is very efficient at degassing mobile phase, as and when required.
The Direct Connection UNIGUARD allows the guard cartridge outlet to be directly placed against the analytical column inlet frit. Product detail: We recommend all analytical columns are protected by a guard cartridge, which is replaced on a regular basis. The ID of the analytical column determines the correct ID for the guard cartridge. We offer 10x1, 10x2, 10x3, 10x4mm guard cartridges in all our stationary phases to ensur…
The Javelin guard design is a one-piece format that can be installed without wrenches and requires no holder, which allows quick and easy replacement. Product detail: We recommend all analytical columns are protected by a guard column or cartridge, which is replaced on a regular basis. The ID of the analytical column determines the correct ID for the guard, so we offer 1.0, 2.1, 3.0 and 4.0 diameter Javelin guard columns in…
HyperREZ™ columns are specially designed for analysis of organic acids, alcohols, saccharides and carbohydrates. They employ a polymeric support with ligand exchange groups. The ligand exchange resins contain highly sulfonated cation exchange resins that have Group I, Group II or transition metals associated with the chromatographic surface.HyperREZ™ columns are based upon a polymeric resin that shows stability from pH 1 to 14…
BioBasic 8 Columnso Improved reproducibility, efficiency and column lifetimeso Range of stationary phases to optimize selectivityo Powerful resolution, even on short column lengths Product detail:BioBasic 8 columns provide exceptional reliability for separations of proteins, peptides, and other biomolecules through a combination of high purity silica and reproducible, stable bonding. The proprietary bonding procedure en…
BetaMax Acid Columns o High surface area area and bonded phase coverage for maximum retention, even in high percentage organic conditionso Chemistries for acidic compounds Product detail: For alternative selectivity to traditional alkyl phases, we recommend you try the polar embedded phase BetaMax columns. The stationary phase contains urea groups embedded within the C12 chain, which extra interactions with samples to…
BETASIL C18 Columnso Broad range of particle sizes and phases for wide method development optionso High surface area and phase coverage for reproducibility and sharp peak shapes Product Detail BETASIL columns are based on 100Å pore size, fully deactivated type B silica to ensure sharp peaks and excellent reproducibility for the analysis of a wide range of compounds. The 100Å pore size gives a higher concentration of statio…
BetaBasic 4 Columnso Excellent peak shapes for basic compoundso Superb stability at both low and high pH Product detail:BetaBasic 4 columns are based on a 150Å pore size, fully deactivated type B pure silica to ensure sharp peaks and excellent reproducibility for the analysis of basic compounds. Due to stable bonding chemistry and excellent surface coverage, BetaBasic 4 columns show excellent peak shape for basic compound…