Latest: The power of microfluidics to enhance particle performance
Latest: Upcoming clinical diagnostics webinars to aid your work
Latest: Accelerating drug discovery and development with single-cell and spatial profiling
Latest: Increase lab efficiency with Restek’s new Canadian pesticide CRM kit
Latest: How to overcome challenges and improve your semivolatile organic compound analysis
Latest: Luminex licensed technologies partner spotlight: Wageningen prime diagnostics
Latest: Analytical science webinars
The power of microfluidics to enhance particle performance
The countdown has begun! Register today for the Virtual Analytical Summit 2023
InDevR partners with bioMérieux
Beckman Coulter Life Sciences completes first phase of Colorado R&D hub with grand opening of $10...
Upcoming life science webinars to empower your research
Accelerating drug discovery and development with single-cell and spatial profiling
Managing the risk of nitrosamines in medicinal drugs
Your essential guide to preparative LC
A method to measure anti-vaccine antibodies
An integrated workflow for the analysis of oligonucleotides and their impurities by Agilent...
Quality control and quality assurance in the food industry
FE-SEM Imaging at 500V
Multiplexing Technology
Water Purification
Microscopy
Biophysical Characterization Technology
Liquid Handling
HPLC Technology
SLAS 2023 Building Biology...
20 Apr 23 - 21 Apr 23
The only high-purity gas that guarantees minimal impurities. Read more...
High Capacity Gas Purifiers (Remove Moisture and Oxygen) The best purifier choice for removing moisture and oxygen from carrier gas streams is our High Capacity Gas Purifier. It consists of three parts: • Clam-shell oven • Replaceable h... Read more...
Supelcarb® is Back by Popular Demand! Supelco® is pleased to welcome the Supelcarb HC Hydrocarbon trap back to our line of in-line gas purifiers! Supelcarb adsorbent has the greatest trapping ability of hydrocarbons per gram of adsorben... Read more...
Specialty In-Line Purifier for GC-MS Helium The most sensitive GC-MS instruments require a steady stream of ultra-high purity (99.99999%) helium for optimal performance. To achieve this level, a specialty purifier is required. These pur... Read more...
Ultra-high capacity for the contaminant of interest; either Moisture, Hydrocarbons, Oxygen, Sulfur and Mercury. For applications with a single contaminant of interest, high capacity contaminant specific traps are your best option, s... Read more...
VICI AG heated helium purifier provides point-of-use purification of helium or other noble gases, such as Ar, Ne, Kr, and Xe, to sub-ppm levels of reactive gaseous impurities, removing even nitrogen and methane. The nitrogen purifier is si... Read more...
Gas purifiers for specific gases designed to go in-line with the carrier or detector gas supply, these gas purifier modules dramatically reduce contaminant PPM levels in helium, hydrogen, nitrogen, or air. They decrease baseline noise and ... Read more...
The Agilent Gas Clean Filter System delivers clean gases, reducing the risks of column damage, sensitivity loss, and instrument downtime. Inserting a Gas Clean Filter System in the gas line immediately before the instrument inlet greatly ... Read more...
NANOCHEM ® WK-Series (White Knight™) purifiers offer the highest lifetimes and the best impurity removal efficiencies in a very economical design. The in-line design enables a very compact footprint and allows drop-in replaceme... Read more...
The Zebron Gas Management Filters and Traps removes contaminants from mobile phase gases which reduces potential column bleed, increases the lifetime of your column, and protects sensitive GC detectors from damage. Plug-In GC and LC-... Read more...
Our Hydrocarbon Traps allow you to refill your trap and remove extremely low levels of hydrocarbons. Big Hydrocarbon Traps (BHT) are ideal for bulk purification applications or where several instruments are plumbed from a single gas sour... Read more...
Our hydrocarbon/moisture traps offer you flexibility -- refill your trap and remove extremely low levels of both moisture and hydrocarbons. Read more...
Agilent's Indicating Oxygen Trap is designed to be used in conjunction with any of our high capacity, non-indicating oxygen traps. When properly installed downstream from the non-indicating trap, the Indicating Oxygen Trap provides a visu... Read more...
Capture contaminants released by split injection systems Split vent traps capture contaminants released by split injection systems. Remember to replace the split vent cartridges every six months. An internal split vent trap is factor... Read more...
Oxygen/moisture adsorbents team up to give you two functionalities in the same trap. Unlike some oxygen/moisture traps, these traps are disposable. Consider the safety, performance, and cost advantages of the Agilent capillary grade oxyg... Read more...
Economy Indicating Moisture Removal Traps Agilent Indicating Moisture Traps are designed to remove water, oil, and organics from gases employed in, but not limited to, gas chromatography. Refillable moisture traps are constructed from ... Read more...
The Renewable Gas Purification System from Agilent not only traps large quantities of contaminants and lasts a long time, but it is also recyclable. Read more...
Extra large gas purifiers (750 cc) are ideal for bulk purification applications or where several instruments are plumbed from a single gas source. They provide a low cost alternative to UHP grade gases. We construct each trap from one piec... Read more...