Latest: Beckman Coulter Life Sciences launches next-generation CytoFLEX SRT Benchtop Cell Sorter
Latest: Malvern Panalytical & Leukocare collaborate on stabilization and formulation development...
Latest: FDA grants emergency use authorization for home collection kit for Advanta Dx SARS-CoV-2...
Latest: Gas chromatography high-resolution mass spectrometer offers new standard of performance...
Latest: Watch highlights from the Virtual Analytical Summit 2021
Latest: Gas chromatography high-resolution mass spectrometer offers new opportunities for...
Latest: New areas of X-ray analysis highlighted in the Rigaku Journal
Best practices & top tools for lab safety
Consistency and quality in raw materials: Building blocks of a reliable in vitro diagnostic assay
INTEGRA’s electronic pipettes eliminate user fatigue and improve pipetting productivity
Breast cancer cell line array from AMSBIO
Increasing CRISPR editing efficiency with novel guide RNA methods: Your questions answered
Essential technology for high-resolution untargeted metabolomics
Increasing LC-MS accessibility for streamlined biotherapeutic analysis
The essential guide to ELISA automation
Imaging-based detection of apoptosis using Spark Cyto’s multicolor application
Efficient heat transfer with Unistats
Sustainable, environmentally safe and future-proof temperature control
Performance Report: fluidlab R-300 Cell Counter
DNA/RNA Purification and Analysis
Pre-Clinical and Clinical Automation
Cell Counting Technology
Cell Analysis Microscopy Equipment
Multiplexing Technology
Microscopy
COVID-19 Research
Virtual Analytical Summit
SelectScience Webinar...
08 Mar 21 - 12 Mar 21
19 Apr 21 - 23 Apr 21
SelectScience Virtual Cancer...
11 May 21 - 12 May 21
21 May 21 - 25 May 21
07 Jun 21 - 11 Jun 21
Advertisement
LOW-NOISE ULTRA-FAST DIGITAL PATCH CLAMP AMPLIFIER SYSTEM Read more...
Integrated Patch Clamp Amplifiers with Data Acquisition System Read more...
Computer-controlled microelectrode amplifier with a high-speed current clamp capable of sharp-electrode, field potential or ion-selective measurements, and a patch clamp for whole-cell, excised or cell-attached patches, bilayers, and elect... Read more...
The NL900D Case & Power Supply unit forms the heart of every NeuroLog System. Modules are not only powered by this unit, but wiring within the case allows signals to be passed between modules without the need for a mass of cable connectio... Read more...
Brownlee's rugged yet easy-to-use amplifiers have four channels of a high gain/low noise amplification, lowpass filter and output offset control. A control knob adjusts amplifier parameters, and an alphanumeric LED readout displays values.... Read more...
In addition to the Model 410 amplifier's features, the Model 440 offers an 8-pole Bessel lowpass filter, auto-zeroing, a line notch filter, highpass filter, multiple memories per channel, and a digital voltmeter on 2 channels. A wide bandw... Read more...
Computer-controlled microelectrode current-clamp and voltage-clamp amplifier, useful for a wide range of intracellular microelectrode recording techniques with several modes of operation: two independent current clamp amplifiers with bridg... Read more...
Premier patch-clamp amplifier for all patch-clamp configurations, with capacitive-feedback and cooling in the headstage for ultra-low noise single-channel recordings. Axopatch 200B is shipped with the following, o Axopatch 200B amplifier... Read more...
The RTCA Analyzer is an electronic analyzer that can, under the control of RTCA Software, measure electronic impedance of sensor electrodes at various signal frequencies. The RTCA Analyzer is capable of computer-controlled signal generatio... Read more...
The PatchStar is an ultra-stable, super smooth micromanipulator with extremely low electrical noise. With a versatile, modular design and user friendly responsive controls, the PatchStar is perfect for a wide range of electrophysiologica... Read more...
The LBM-7 was designed and developed in conjunction with scientists to be stable, have low drift and be easy to use. It bridges the gap between coarse manipulators and micromanipulators. Affectionately known as the Little Blue Manipula... Read more...
The IonFlux 16 is the world's first multi-channel automated patch clamp instrument designed and priced for the research environment. The system utilizes Fluxion's Well Plate Microfluidics™ (WPM) to conduct patch clamp measurements in a con... Read more...
The DP-301 is a single channel AC/DC differential pre-amplifier highly suited for EEG, EKG and extracellular recording. High input impedance High common mode rejection Low noise with high gain High tolerance to DC offse... Read more...
The EPC 10 Double and EPC 10 Triple patch clamp amplifiers are the optimal instruments for performing double or triple patch experiments. Although either two (EPC 10 Double) or three (EPC 10 Triple) amplifiers are combined in a single hous... Read more...
The AURA® PSG Ambulatory System is a powerful, easy-to-use polysomnography system consisting of a high quality 25-channel AURA PSG Amplifier System with built-in electrode/sensor inputs and built-in oximeter designed especially for PSG, ... Read more...
The Model 2400 is a low-noise, full-featured intracellular/extracellular amplifier designed for voltage clamping using patch electrodes on single channels or whole cells. Its unique design allows fast intracellular current clamp measuremen... Read more...