ResourceSeparations

Oasis PRiME HLB Cartridges and DisQuE QuEChERS Products for UPLC-MS/MS Mycotoxin Analysis in Cereal Grains

21 Nov 2017

Ingestion of food containing only parts-per-billion (µg/kg) concentration of some mycotoxins may cause severe illness. Therefore, sensitive and reliable analytical methods are required to determine mycotoxins in foods and feeds. An improved QuEChERS extraction procedure was shown to be effective for simultaneous extraction of 12 mycotoxins from wheat, rice and maize flours.

ACQUITY UPLC M-Class System with HDX Technology

Waters

The ACQUITY UPLC® M-Class System with HDX Technology leverages UPLC® separations and high-resolution MS to answer important questions about changes in protein conformation including: Drug candidate binding to a protein Biopharmaceutical product development Protein-protein interactions Intellectual Property The unprecedented system-level design integrates all the steps necessary to accurately, reproducibly, and most of all, easily, perform protein conformation studies. The system and its DynamX™ HDX Analysis Software removes the barriers to adopting high resolution LC and MS for routine studies of protein conformational changes, making hydrogen deuterium exchange with MS (HDX, HDX MS, HXMS, or H/D exchange) a core competency for your laboratory.

(0)

DisQuE Quechers, AOAC Method Sample Preparation Kit, Pouches

Waters

DisQuE Dispersive Sample Preparation used for QUECHERS Method AOAC Method 2007.01. The kit consists of 100 units each of salt pouches, empty 50mL centrifuge tubes and clean-up tubes. Each DisQuE pouch contains 6 grams of magnesium sulphate and 1.5 grams of sodium acetate. Each 2 mL DisQuE Clean-Up tube contains 150 mg of magnesium sulphate and 50 mg PSA (primary-secondary amine SPE sorbent)

(0)

DisQuE Dispersive Sample Preparation Kit

Waters

DisQuE Dispersive Sample Preparation is a well proven, high throughput sample preparation method for a wide array of pesticides in produce. The kit contains conveniently packaged vials with pre-measured sorbents and buffers used to provide extraction and clean-up for up to 100 samples. Each 50 mL DisQuE Extraction tube contains 6 grams of magnesium sulphate and 1.5 grams of sodium acetate. Each 2 mL DisQuE Clean-Up tube contains 150 mg of magnesium sulphate and 50 mg PSA (primary-secondary amine SPE sorbent). Detailed method instructions are included with the kit.

(0)

Links

Tags

Oasis PRiME HLB Cartridges and DisQuE QuEChERS Products for UPLC-MS/MS Mycotoxin Analysis in Cereal Grains