ResourceSeparations

Determination of Carbendazim in Orange Juice using QuEChERS with LC/MS/MS Detection

29 May 2012

The planar fungicide carbendazim (CASRN 10605-21-7) can be used to control mold on citrus crops but is not approved for use in the US or on imported products. This note presents a method where concentrations in citrus products can be rapidly and accurately determined using a QuEChERS extraction with dSPE cleanup. LOD and LOQ for this method are 0.4 and 1.4 ng/mL, respectively.

ChloroFiltr® for QuEChERS dSPE Clean-Up

UCT, Inc.

Chlorophyll in QuEChERS extracts must be removed to reduce potential instrument downtime. This is removed from extracts using graphitized carbon black (GCB) Unfortunately, GCB also removes planar analytes reducing analytical accuracy. ChloroFiltr®, used in place of GCB in dSPE tubes, removes unwanted chlorophyll without removing pesticides or environmental analytes. No change in procedure are required.

(0)

Links