Average Rating 4.7

|8Scientists have reviewed this product

Ease of Use
After Sales Service
Value for Money
Write your own review

Rendimiento fiable y requiere espacio pequeño en el laboratorio / Reliable performance and requires little space in the laboratory

 

Average Rating 4.0

Application Area:

Farmacologia / Pharmacology

Espectrómetro de masas de triple cuadrupolo Xevo TQ-S micro Diseñado teniendo en cuenta el análisis cuantitativo y el velocidad de análisis de muestras, puede beneficiar al laboratorio por obtener datos analíticos de alta calidad, inyección tras inyección, cumpliendo con los requisitos normativos, de acreditación y de calidad. La fiabilidad del funcionamiento del instrumento maximiza la eficiencia del laboratorio y ofrece una sensibilidad extraordinaria para un instrumento de tamaño tan compacto. / Xevo TQ-S micro Triple Quadrupole Mass Spectrometer Designed with quantitative analysis and rapid sample processing in mind, this instrument can benefit laboratories by providing high-quality analytical data, injection after injection, while meeting regulatory, accreditation, and quality requirements. The instrument's reliable operation maximizes laboratory efficiency and offers exceptional sensitivity for such a compact instrument.

Review Date: 9 Mar 2026 | Waters

Without this technology I would no longer have a passion for my research.

 

Average Rating 4.7

Application Area:

Pesticides and veterinary drug analysis

The Xevo TQ-S micro Technology is an excellent technology from Waters for the analysis of Pesticides and veterinary drugs in several matrices. We have acquired this technology since 2019 and since its installation today I have had better results. These very repeatable and reproducible results are illustrated through the intercomparison tests that we do with Bipea, FAO and FAPAS. It is a very effective technology that saves us time on analyses. The creation of the analysis project, the Quandpédia databases, the creation of an analysis sequence and the processing of the results according to Masslynx are very understandable and very fast. The few times we have had difficulty, the after-sales service responds effectively. Really it is a technology that does not tire me. Through my results, I have already encouraged my bosses to get us a new Waters model.

Review Date: 11 Feb 2022 | Waters

Sharper peaks & good % RSD, wider pH range peaks with 1.7micron column .

 

Average Rating 5.0

Application Area:

Environmental analyses, food safety

Easy to use, empower software is super. Service and support always good in my region.

Review Date: 6 Jun 2021 | Waters

Worth buying in terms of price compared to equivalent instruments.

 

Average Rating 5.0

Application Area:

Bioanalysis

Very good instrument in terms of sensitivity and reproducibility. We had four systems in our bioanalytical lab. We applied method parameters for a compound which was developed in one system to all four systems. There is no change in chromatography, base line noise.

Review Date: 22 Sept 2020 | Waters

Robust, good results, expensive.

 

Average Rating 4.7

Application Area:

Residual pesticide analysis

The equipment is user friendly, software friendly. The equipment has low quantitation limit values, is robust, and accurate. After-sales service is good. Disadvantage: Consumables are expensive.

Review Date: 2 Dec 2019 | Waters

Excellent compact workhorse LC-MS/MS.

 

Average Rating 4.3

Application Area:

Environmental analysis

This is a good LC-MS/MS system for day-to-day environmental analysis. Compact, easy to use and easy to maintain.

Review Date: 25 Oct 2018 | Waters

Very user friendly!

 

Average Rating 4.7

Application Area:

Measuring THC in patient biosamples (breath, oral fluid, and whole blood)

The software for instrument and data processing is extremely user friendly compared to other vendors used. The instrument is also well made and user friendly, facilitating easy maintenance.

Review Date: 31 Jul 2018 | Waters

Great instrument, fantastic service/applications support

 

Average Rating 5.0

Application Area:

Food and Beverage analysis

The Waters TQ-S micro MS system with an Acquity I-Class UPLC is a new addition to our lab. The instrument has excellent performance both with regards to UPLC and MS. More importantly, Waters has demonstrated themselves as an excellent partner with regards to installation of the instrument, applications training, etc. We had an initial issue with the instrument after installation that wound up being related to a faulty component on the communications board. The team was committed to finding a prompt resolution to the issue and their diligent work minimized down-time. Once the problem was fixed, they even worked with us to modify the service contract to reflect the true date of when the instrument became operational. Fantastic service and support behind a great LC-MS system.

Review Date: 26 Jun 2018 | Waters

Revolutionary design has produced a tandem quadrupole instrument with a small footprint that delivers consistent low levels of quantitation with a wide dynamic range.

With new performance enhancements, the Xevo™ TQ-S micro enables you to routinely determine highly polar, ionic compounds in food. Software enhancements also enable results to be reviewed easier and faster and provide automated functions that allow new methods to be developed and existing methods to be optimized, much more easily.

When combined with superior performance per square inch and exceptional analytical flexibility, the Xevo TQ-S micro delivers reproducible high-quality analytical performance, even with the most complex sample matrices.

Application NoteLife Sciences

Determination of vitamin D and previtamin D in food products

This application note demonstrates an improvement in the current LC-MS method for vitamin D analysis. It demonstrates the determination of total vitamin D by individually measuring the vitamin D and previtamin D in food products. Previtamin D was directly measured in the total vitamin D analysis, eliminating the error that could arise from not measuring previtamin D. This method will be less affected by the heating history of food products.






Application NoteCannabis Testing

Cannabis and hemp testing

In this brochure, Waters presents solutions for plant-to-product cannabis testing to help regulated laboratories consistently deliver accurate results.




Application NoteSpectroscopy

Multiresidue Analysis of Pesticides in Fruits and Vegetables Using UPLC-MS/MS

In this application note, the development of a multiresidue method for the routine determination of 190 pesticide residues in various fruit and vegetable matrices using UPLC-MS/MS is described. White grapes and green beens were selected for this application due to their relatively increased complexity, since they contain chlorophylls which are known to affect the extraction efficiency of pesticides from food matrices. A generic QuEChERS sample extraction procedure was used to extract the pesticides from the samples, followed by a rapid and high resolution UPLC separation and trace level detection of pesticides using the Xevo TQ-S micro.


White PapersSeparations

Minimizing Phospholipid Interference During LC-MS/MS Analysis of Vitamin D Metabolites in Serum for Clinical Research

Interferences by matrix components can be challenging when measuring serum levels of vitamin D metabolites by LC-MS/MS, particularly lysophosphatidylcholines. They are challenging to remove during sample preparation and difficult to separate chromatographically. This white paper describes an approach for method optimization using the Oasis PRiME HLB solid phase extraction plate, from Waters.

Regional drug use trends aid fight against evolving opioid epidemic

The opioid epidemic in the US is a severe public health crisis, with increasing misuse, addiction, and overdose deaths. Central to tackling opioid dependence are dedicated treatment plans using opioid substitute therapy. However, as the crises evolves into its now fourth wave, different regions are exposed to different concoctions of drugs and so a more personalized approach to evaluating compliance with therapy is required.

Speaking with Dr. JP Canner, Chief Scientific Officer and Laboratory Director at Gravity Diagnostics, we explore how this state-of-the-art CAP-accredited and CLIA-certified laboratory is expanding its drug testing menus to respond to regional drug use patterns seen as part of its clinical toxicology services.



Integrating LC-MS into the Clinical Laboratory

As a leading clinical LC-MS/MS solutions partner, Waters is a trusted provider of in vitro diagnostic medical devices, consumables, informatics, and support services for high performance LC-MS/MS systems. Learn how and why University Hospital of South Manchester has introduced Waters LC-MS/MS IVD instrumentation into their busy clinical laboratory.









Product Overview

Links