Avio® 3000 ICP Optical Emission Spectrometer
The Avio® 3000, the latest extension of PerkinElmer’s ICP-OES portfolio, redefines true simultaneous ICP-OES, delivering high speed of analysis and accurate, defensible data—every run, every day—while keeping operational costs under control.
This is thanks to the combination of next-generation patented technologies (new HeliPlate™ plasma technology, new cutting-edge optical system with UV Boost capability, new 3rd generation detector, no chiller required) seamlessly integrated with field-proven ones to deliver unrivaled ICP-OES performance with the lowest operating costs.
Proprietary features of the Avio 3000 ICP-OES include:
- Next-Generation Detector delivers improved precision and speed with full spectral coverage and higher signal-to-noise measurements, for higher sample throughput and improved data quality.
- Cutting-Edge Optical System enables the measurement of lower concentrations more accurately and consistently, simplifying operation while improving data quality
- UV Boost Mode allows accurate measurements at lower concentrations, both in normal and high-resolution modes, while also unlocking secondary emission lines previously too weak to utilize effectively, boosting the potential of your ICP-OES analyses.
- HeliPlate™ plasma technology builds on the proven Flat Plate™ oscillator design that consumes up to 50% less argon than traditional helical coils, while delivering improved plasma robustness and not requiring a chiller.
- Chiller-free design significantly reduces operating costs by providing savings in electricity, heat, noise, maintenance, as well as reducing carbon footprint, while also occupying less lab space.
- Vertical Dual View optimizes axial and radial plasma viewing to the extended linear dynamic range, measuring high and low concentrations in the same run, regardless of wavelength.
- PlasmaShear™ design offers maintenance-free, argon-free interference removal, enabling interference-free axial viewing, extended linear range, and reduced maintenance for complex samples.
- Universal Data Acquisition in Syngistix software enables simultaneous acquisition of all available wavelengths, with virtually no time or storage penalty.
- Multicomponent Spectral Fitting corrects spectral interferences in real time, improving accuracy and simplifying method development.
- Syngistix™ for ICP Software provides an intuitive, left-to-right, icon-based design, mirroring the progression of your workflow with smart features that guide you through each step for greater control and confidence.
- LED Status Lights with 360-degree viewing provides real-time instrument feedback.
For added flexibility, the Avio 3000 ICP-OES is available in four configurations, allowing you to select the option best suited for your application(s):
- Avio 3000 ICP-OES with HTS, Cyclonic glass spray chamber and Concentric glass nebulizer (N0840008) provides higher throughput and efficiency, better precision, and faster washout times, but is not recommended for hydrofluoric acid applications.
- Avio 3000 ICP-OES with Scott double-pass Ryton spray chamber and Cross-Flow nebulizer (N0840009) is suitable for most applications, even those requiring hydrofluoric acid.
- Avio 3000 ICP-OES with Cyclonic glass spray chamber and Concentric glass nebulizer (N0840010) is designed to provide higher efficiency, better precision, and faster washout times, but is not recommended for hydrofluoric acid applications.
- Avio 3000 ICP-OES Oils System (N0840018) is ideal for organic analysis applications such as the Caterpillar® S.O.S. Program and ASTM® methods D4951 and D5185.
TechTalk: How the latest technology in the Avio® 3000 redefines ICP-OES and improves your bottom line
Friday, June 26 at 14:00 BST | 15:00 CEST | 09:00 EDT | 06:00 PDT
In this SelectScience® TechTalk, discover how PerkinElmer’s new Avio® 3000 ICP-OES is redefining trace elemental analysis with a powerful combination of speed, sensitivity, robustness, and operational efficiency.
This presentation will explore the innovative technologies behind the Avio 3000, including patented HeliPlate™ plasma technology, a next-generation detector, advanced optical design with UV Boost capability, and true simultaneous multi-element analysis. Learn how these innovations deliver high-quality, defensible results while reducing argon consumption, eliminating the need for a chiller, and simplifying laboratory workflows.
The session will also highlight how the system supports demanding applications across environmental, industrial, food, and materials testing laboratories, helping organizations improve throughput, lower operating costs, and maintain confidence in their analytical data.