LipiFiltr
Targeted lipid removal from fruit, vegetable, and agricultural based sample types.
The easy-to-use LipiFiltr® push-through purification cartridge was designed to remove lipids from acetonitrile extracts. Samples are extracted using a standard QuEChERS procedure and an aliquot of the supernatant is simply pushed through the LipiFiltr® purification cartridge using a disposable syringe. The purified extract is collected in an autosampler vial and analyzed by UHPLC-MS/MS. The ability to obtain significantly cleaner extracts, ease of use, and time and cost savings make the new LipiFiltr® push-through cartridges an attractive cleanup option for laboratories conducting pesticide residue analysis in complex fatty samples.
Streamlined method for pesticide residues in high-lipid food samples using QuEChERS extraction, LipiFiltr cleanup and UHPLC-MS/MS analysis
Download this application note, which outlines the performance benefits achieved using the new LipiFiltr® cartridge in applications involving multi-class, multi-residue analysis for a wide range of pesticides (n=189) in complex, high-fat samples.
Optimization of Sample Preparation for Pesticide Analysis in Oil-Based Cannabis Products using LipiFiltr
This application note outlines the performance benefits achieved using the LipiFiltr® cleanup cartridge for the analysis of pesticides in oil-based cannabis products using LC-MS/MS analysis. The pesticides evaluated in this study include those listed in the Oregon monitoring list (≈60 pesticides). CBD oil was used as the representative matrix. A comparison of pre- and post-LipiFiltr® cleanup using full scan GC-MS is also presented to demonstrate the removal of lipid coextractives. This work was originally presented as a poster at the North American Chemical Residue Workshop (NACRW) 2018 in Naples, Florida.
Streamlined Method for Pesticide Residues in High-Lipid Food Samples using QuEChERS Extraction, LipiFiltr® Cleanup and UHPLC-MS/MS Analysis
This application note outlines the performance benefits achieved using the new LipiFiltr® cartridge in applications involving multi-class, multi-residue analysis for a wide range of pesticides (n=189) in complex, high fat samples. The easy-to-use LipiFiltr® push-through purification cartridge was designed to remove lipids from acetonitrile extracts. Samples are extracted using a standard QuEChERS procedure and an aliquot of the supernatant is simply pushed through the LipiFiltr® purification cartridge using a disposable syringe. The purified extract is collected in an autosampler vial and analyzed by UHPLC-MS/MS. The ability to obtain significantly cleaner extracts, ease of use, and time and cost savings make the new LipiFiltr® push-through cartridges an attractive cleanup option for laboratories conducting pesticide residue analysis in complex fatty samples.
Pesticides & Contamination: SelectScience Special Feature
From potency testing and profiling to multi-residue and trace-level detection, find out the latest techniques and technologies advancing the field of pesticide and contaminant testing
5 top resources for pesticide analysis in cannabis testing
Simplify the task of removing pesticide and herbicide residues to meet regulatory standards with these vital resources
Trending in analytical chemistry – Latest applications of solid phase extraction
From cannabis testing to environmental monitoring, find out how scientists are using SPE to speed up and innovate their sample preparation






















