Priorclave RCS Autoclaves Can Improve Lab Efficiency

19 Aug 2014
Sarah Thomas
Associate Editor

The RSC 350 laboratory autoclave from specialist autoclave manufacturer Priorclave is proving to be the ideal choice for those laboratories in the food and drink, dairy, pharmaceutical, agriculture, education, healthcare and research sectors looking to achieve high-throughput sterilizing procedures or have a requirement to process large bulky items.

The popularity of this front-loading autoclave is driven by a design that offers a large sterilizing chamber yet requires a relatively small footprint and is by far one of the easiest to install since it is castor mounted for easy positioning and pass through a standard door.

With a 350 liter capacity chamber the RCS 350 laboratory autoclave is the perfect choice where tall, small and bulky items need to be sterilized since the rectangular chamber will accommodate many differing media types and sizes side-by-side in a single process. This can often improve the daily throughput of a busy laboratory.

All steam sterilizing process parameters are easily programmed through the advanced Tactrol® 2 microprocessor control system, allowing for adjustment of temperature and time for simple cycles to fully featured multi-program operation. This powerful controller allows unrivalled flexibility, monitoring and management of the process cycle, it guides operators through simple set-up procedures ensuring laboratories optimize the autoclave performance in relation to the media being processed and thus helping to reduce running costs.

Priorclave is a technical innovator in autoclave design and this is reflected in the RCS 350 autoclave with features such as lower loading heights, simpler set-up procedures and safer door opening mechanisms. The chamber door on the RCS 350 has a patented two hand-wheel door closure system, the lower hand-wheel on the chamber door is fitted with thermal and pressure locks to prevent opening at load temperatures above 80°C and pressures above 0.2 bar, thus averting potential accidents through discharge of hot, high-pressurized steam.

The RSC 350 can be supplied by Priorclave with a choice of steam generation – electrical or direct steam heated; alternatively they can be fitted with an in-house steam generator ideal where continuous sterilizing applications take place.

As standard, the RSC 350 front loading laboratory autoclave is fitted with an automatic water-fill however as a dedicated autoclave manufacturer Priorclave is able to incorporate a number of options into the standard sterilizer framework of these high capacity sterilizers such as water cooling jackets, pre-cycle vacuum in which multiple vacuum stages are programmed with interspersed heating to achieve greater steam penetration of difficult media as well as post cycle drying.

The RSC 350 autoclave also benefits from Biomaster protection, a tough special epoxy finish proven to reduce bacterial growth by up to 99.99% and is highly effective against MRSA, E coli, Listeria, Legionella, Campylobacter, Salmonella, Pseudomonas and over 50 other species.

Purchase of a RSC 350 autoclave means buying into British designed and manufactured laboratory autoclaves that have a global presence and are supported by one of the very best pre-and aftersales support service, a dedicated team ensures customers maximize the efficiency of their Priorclave wherever it is installed.

RSC Front Loading Rectangular Autoclaves

Priorclave Ltd

Priorclave Rectangular Section autoclaves combine a huge internal capacity with a small floor area.Perfect for high volume steam sterilising throughput as well as being able to accommodate large or bulky items, the Priorclave rectangular chamber RSC front loading autoclaves combine huge internal capacity with a small floor area making them a very viable purchase for most laboratories.This range is available with a choice of heating systems -electrical or direct steam heated or they can be fitted with an in-built steam generator - and offers five chamber sizes from 230 to 700 litres. In addition to standard designs RSC autoclaves can be fitted with optional water jackets to help accelerate the heating or reduce the cooling process.All models are fitted with non-tipping shelves and can be supplied stainless steel baskets, waste containers and loading trolleys if required to suit the application.RSC Front Loading Rectangular Autoclaves Features: Capacities from 230 to 700 Litres and above. Intermediate sizes available to suit individual locations where required. Operation up to 140C - 2.5 Bar Large rectangular chamber within a compact frame Steam generated within the chamber (electrically heated models) - Direct steam heated models available Complete with thermocouple entry and test ports Forced air cooling as standard helping to reduce cycle times Automatic timed freesteaming as standard for improved air removal and sterilising performance Delayed start and media warming function as standard for ready to pour media at the start of the day A large selection of options and accessories is available to help to get the most from your Priorclave autoclave Supplied with two full width non-tipping stainless steel shelves. Stainless steel baskets, waste containers and loading trolleys available