Selective Analysis of Patulin in Apple Juice Using the ACQUITY UPLC H-Class System with the ACQUITY QDa Detector
18 Sept 2014This application note presents an ACQUITY UPLC method using mass detection with the ACQUITY QDa Detector.
This application note presents an ACQUITY UPLC method using mass detection with the ACQUITY QDa Detector.

The ACQUITY QDa® Mass Detector gives you certainty above all else. You can minimize the risk of unexpected coelutions or components and confirms trace components with the analytical confidence of mass detection. The ACQUITY QDa® Detector is a mass detector built around the needs of analytical scientists for chromatographic analysis. Robust, reliable and requiring no sample adjustments, it just integrates with your current LC, ACQUITY UPLC, ACQUITY UPC2 and purification systems. You'll enhance the analytical value and productivity of each analysis, and you won't need to run all the additional assays or time-consuming alternative techniques or even wait for results from specialist labs that cost your laboratory productivity. With the ACQUITY QDa® Detector, you now have information-rich mass spectral data to complement data from your current Waters® optical detectors, including the ACQUITY UPLC PDA, TUV, ELS, and FLR detectors, as well as the ACQUITY UPC² PDA Detector. This mass spectral information integrates seamlessly into the same workflow; routinely giving you more complete separation characterization. Features: Intuitive operation More information from every sample Effortless integration Increased efficiency Resolving complexity Applications: Food & Environment Life Sciences and Pharmaceuticals Chemical

Transform standard procedures into ultimate performance.

Acquire, Analyze, Manage, and Share Mass Spectrometry Information MassLynx™ Software increases the speed at which you can convert your sample data into valuable knowledge. It provides you with the fundamental platform to acquire, analyze, manage, and share your mass spectrometry information. MassLynx intelligently controls any Waters mass spectrometry system, from sample and solvent management components to mass spectrometer and auxiliary detectors. MassLynx Software may acquire nominal mass, exact mass, MS/MS and exact mass MS/MS data. MassLynx’s Sample List is the core of the system. It maintains and consolidates the data on all of your samples. You also initiate any activities related to your sample from the Sample List. This "sample centric" approach simplifies the interaction with your LC/MS or GC/MS system, acquired data and processed results. Process Application-specific Data MassLynx Software features general purpose and specialized Application Managers that provide information for your specific MS analyses and data. Two come standard with MassLynx: QuanLynx™ for automated quantification included as standard with MassLynx OpenLynx™ for qualitative screening and identification Optional Application Managers can perform: Targeted quantitative analysis Mass-directed purification Metabolite identification Deconvolution of complex chromatograms Metabonomics & metabolomics Protein identification and protein characterization

The TargetLynx™ Application Manager automates sample data acquisition, processing and reporting for quantitative results.It incorporates a range of confirmatory checks that identify samples that fall outside user-specified or regulatory thresholds. Identify Non-compliant Samples TargetLynx rapidly identifies and flags samples where: Analytes are above a specified maximum reporting level (MRL) Analyte confirmatory ion ratios are outside specified limits One or more analyte signal-to-noise ratios are below a defined value An analyte retention time or relative retention time is outside limits An analyte concentration is below set LOD and LOQ thresholds The standard deviation of response for QC standards exceeds a defined value The blank response is too high The coefficient of determination (r2) of the calibration curve exceeds a defined value LC/MS & LC/MS/MS and GC/MS & GC/MS/MS Use TargetLynx to quantify and confirm both LC/MS & LC/MS/MS and GC/MS & GC/MS/MS data. This data may be selected ion monitoring (SIM), multiple reaction monitoring (MRM), or full scan/full spectrum. In the case of full scan/spectrum data, extracted ion chromatograms are used for quantification. Ensure Regulatory Compliance The demand by regulatory authorities for assurance of confirmation in quantitative analysis continues to increase. To ensure cost-effective compliance, TargetLynx offers software that gives you confidence in your results and eliminates time-consuming, costly manual checks.