ResourceSeparations

Improved Recoveries and Lower Background for the Analysis of PAHs in Olive Oil

11 Sept 2014

This study compares the Supelclean EZ-POP NP and two competitor silica gel SPE cartridges in terms of matrix removal and analyte recovery for the extraction of select polycyclic aromatic hydrocarbons (PAHs) from olive oil.

SLB-5ms Capillary GC Column

Sigma-Aldrich Supelco

SLB-5ms Capillary GC Column Application: The 5% phenyl equivalent phase provides a boiling point elution order with a slight increase in selectivity, especially for aromatic compounds. The low bleed characteristics, inertness, and durable nature make it the column of choice for environmental analytes (such as semivolatiles, pesticides, PCBs, and herbicides) or anywhere a low bleed non-polar column is required. USP Code: This column meets USP G27 and G36 requirements. Phase: Bonded and highly crosslinked; silphenylene polymer virtually equivalent in polarity to poly(5% diphenyl/95% dimethyl siloxane) Temp. Limits: ≤0.32 mm I.D.: -60 °C to 340 °C (isothermal) or 360 °C (programmed) Temp. Limits: ≥0.53 mm I.D.: -60 °C to 330 °C (isothermal) or 340 °C (programmed)

(1)

Supelclean™ EZ-POP NP

Sigma-Aldrich Supelco

This multi-bed solid phase extraction (SPE) cartridge was designed for the extraction of non-polar persistent organic pollutants (POPs), specifically heavy and light polynuclear aromatic hydrocarbons (PAHs), from edible oil matrices such as olive and corn oil. Fatty matrix is preferentially retained by the cartridge while PAHs are washed through using acetonitrile. The resulting extract is suitable for either GC-MS or HPLC-FLD analysis. The top layer of the SPE cartridge consists of Florisil®, a polar adsorption media that interacts with polar functional groups such as acids and alcohols. The bottom layer is comprised of a mixture of Discovery® DSC-18 and Z-Sep sorbents. C18 binds fatty matrix through hydrophobic interaction. Z-Sep, a zirconia coated silica, acts as a Lewis acid, interacting with the oxygen within OH and COOH groups found in fatty acids and mono and diacylglycerols.Features: Dual layer SPE that contains both LC-Florisil® (upper layer) and Z-Sep/C18 (lower layer) SPE sorbents, separated by a PE frit. Developed to offer superior cleanup when analyzing non-polar persistent organic pollutants (POPs) from oil matrices. Fatty matrix is preferentially retained by the cartridge, while non-polar POPs are washed through using acetonitrile.

(0)

Links

Tags

Improved Recoveries and Lower Background for the Analysis of PAHs in Olive Oil