EconoFit Chromatography Columns
Bio-RadUse our prepacked low-pressure chromatography columns with any chromatography system. Choose Ion Exchange, Affinity, Desalting, or patented Mixed-Mode resins.
Use our prepacked low-pressure chromatography columns with any chromatography system. Choose Ion Exchange, Affinity, Desalting, or patented Mixed-Mode resins.
(6aR,9R)-Δ10 -THC (CRM) (Item No. 33011) is a certified reference material that is structurally similar to known phytocannabinoids and has been found as a byproduct in Cannabis processing. It is regulated as a Schedule I compound in the United States and is provided as a DEA exempt preparation. Also available are (6aR,9S)-Δ10 -THC (CRM) (Item No. 33012), 9(R)-Δ6a,10a -THC (CRM) (Item No. 33013), and 9(S)-Δ6a,10a -THC (CRM) (I…
Employs the unique and universal Charged Aerosol Detector to consistently quantify all non-volatile and semi-volatile compounds even when no reference standard is available. Improve your lab's quantification capabilities with the Thermo Scientific Vanquish Duo HPLC and UHPLC Systems for Inverse Gradient.
Increase your throughput and maximize detector output using a second pump and intelligent column switching to eliminate the time required for column equilibration in gradient elutions. The Thermo Scientific Vanquish Duo HPLC and UHPLC Systems for Tandem LC or LC-MS increase sample throughput for any LC or LC-MS analysis.
Double your throughput and deepen your sample analysis using the Thermo Scientific Vanquish Duo UHPLC System for Dual LC. Features a dual split sampler and two pumps and flow paths, allowing you to run the same method or two different methods simultaneously on the same instrument, maximizing your lab productivity and return on investment.
Perform analyte pre-concentration and sample clean-up using an automated, repeatable workflow while saving your solvent usage and time compared to offline sample preparation steps. Ensure confidence in your complex sample analysis with the Thermo Scientific Vanquish Online SPE HPLC and UHPLC Systems.
Heart-Cut 2D-LC can reveal hidden impurities that co-elute with the analytes of interest by using two complementary column chemistries to gain more separation power. Increase your confidence in peak purity using the Thermo Scientific Vanquish Loop Heart-Cut 2D-LC System.
Achieve in-depth analysis for greater confidence in peak purity and identity with the Thermo Scientific Vanquish Trap Heart-Cut 2D-LC System. This two-dimensional LC (LC-LC) system enables you to collect a single fraction of the first-dimension separation onto a trap column to pre-concentrate or achieve mobile phase compatibility for UV and MS detection.
This two-dimensional LC (LC-LC) system is an innovative, all-in-one system that uses the novel Thermo Scientific Vanquish Dual Split Sampler to enable you to switch between both system capabilities without re-plumbing. Seamlessly switch between a trap heart-cut 2D-LC system and a dual LC system using the innovative Thermo Scientific Vanquish Simple Switch 2D-LC System.
Accelerate and automate your method development using Thermo Scientific Vanquish Method Development HPLC and UHPLC systems. These systems optimize separation conditions by testing thirteen different eluents on up to six HPLC columns. Achieve fully automated method development with ChromSwordAuto Chromeleon Connect and ChromSword AutoRobust Chromeleon Connect.
Pkg of 1, includes UV/Vis and conductivity detector kit with necessary tubing and fittings, for protein, peptide, nucleic acid, and chromophore detection
Spring Loaded HPLC Column Fitting with Stainless Steel Laser Cut precision tubing. A quick and easy connection with all brands of Columns to help in reducing Peak broadening and poor connections.
The Beta Tool-2 is a precision plier for use with 1/16” or 1/8” Stainless Steel HPLC Tubing.
SeQuant ® HILIC (hydrophilic interaction liquid chromatography) HPLC columns carry densely bonded, zwitterionic functional groups. These columns are available in a variety of lengths, particle sizes, and pore dimensions while showing an exceptional reproducibility and robustness.
Chromolith ® columns have shown great potential and superiority in comparison to standard silica. In contrast to conventional, packed-particle columns, wide pore (300 Å) monolithic silica columns are made of a single continuous-bed rod of high purity porous silica that is then bonded with C18, C8, C4, Epoxy, and Protein A depending on the use of the column.
The Dursan surface treatment uses a functionalized, silica-like coating for stainless steel frits and column tubes. The coating is very robust and thin (~400 - 1600nm) that modifies the contact surface your analytes meet to be metal-free and somewhat hydrophobic.
HPLC Column Filters with a Stainless-Steel Filter Element and all PEEK body. These filters are finger-tight fittings installed by hand tightening into the inlet of most HPLC Columns and Guard Columns.
Cogent Amide Hydride™ HPLC Columns are manufactured with TYPE-C™ silica (silica hydride) and have an ethyl amide functional group bonded to the silica particle with direct, silicone-carbon bonds. The manufacturing of silica makes these columns extremely stable.
MicroSolv PFAS Brand Caps and vials are designed for PFAS Testing and Storage. They are manufactured with the purest Silicone Rubber and pure, virgin, medical grade polypropylene and without any PTFE. Our single-use Cap is the purest cap available.
Cogent Silica-C™ HPLC Columns is a silica that has a Silica-Hydride surface that is completely free of carbon. This unique stationary phase will adsorb and desorb solvents commonly used in mobile phases very differently from ordinary silica resulting in fantastic benefits to the chromatographer.
Cogent HPS HPLC Columns are unique columns for Reversed and Normal Phase HPLC. Cogent HPS™ HPLC columns have been used in the industry for over 20 years in many USP © methods as well as methods developed in-house. They also serve as a Certified PQ column. They are manufactured in the USA and are available globally through local distributors. MicroSolv’s Research and Development and Technical support laboratories assist our c…
Streamline your work processes and save time and money with Fused-Insert Vials instead of using separate “drop-in the vial” inserts. Fused inserts are very economical as there is no breakage or tedious filling of “hand–held” single inserts that must be carefully placed into a vial. Fused inserts are stationary, enabling you to hold the vial without damaging the insert and your sample.
The cannabis industry uses ICP-MS and AA to test for heavy metals. Nitric Acid, Ultratrace from Spectrum Chemical is a strong, highly corrosive mineral acid with extremely low metal content (over 50 with levels less than 100 PPT) ideal for this purpose due to its primary use as an analytical reagent in elemental analysis determinations using ICP and AA techniques, digestion of water samples, and as a doping agent for organic…
Cogent IEX™ HPLC columns have been available for over 20 years in the industry and are used in many USP© methods as well as methods developed in-house. Ion exchange chromatography is the most popular method for the purification and analysis of charged molecules. (IEX) HPLC is the separation of polar (charged) molecules including and not limited to amino acids, proteins, peptides, organic acids, and bases, based on their affin…
Cogent Diol™ HPLC Columns are manufactured with TYPE-C™ silica (silica hydride) and are excellent for polar compounds. With extremely fast equilibration between gradient runs, these columns are a popular choice for polar compounds using HPLC or LCMS.