SPE Sorbents Products & Reviews

25

SPE Sorbents

Product Filter

Explore by Field
Solid-Phase Extraction
SPE Sorbents
Explore by Company

Ratings

Search

Selected Filters:

Clean Screen® FASt THC

UCT, Inc.

CLEAN SCREEN FASt THC is the newest sorbent in our FASt product lineup. It employs a process that uses positive pressure and a solid phase sorbent bed built with small pore frits to quickly and efficiently prepare urine samples for LC/MS analysis. This method eliminates timely centrifugation, reduces matrix suppression effects, and removes particulates greater than ~1μm. Samples can be diluted at a ratio as low as 1:1, which i…

0.0/5.0
|0 Reviews
Request Pricing

Clean Screen® THC

UCT, Inc.

The CLEAN SCREEN® THC column is copolymerized on a rigid, purified silica gel support. The two functional groups include a reverse phase, and an ion exchanger, primary amine. This column is commonly used for analyzing THC and its metabolites. It has dual functionality for acids and hydrophobic compounds.

0.0/5.0
|0 Reviews
Request Pricing



Clean Screen FASt®EtG

UCT, Inc.

CLEAN SCREEN FASt EtG is the newest sorbent in our FASt product lineup. Similar to the other products in the FASt line, it employs a process that uses positive pressure and a solid phase sorbent bed built with small pore frits to quickly and efficiently prepare urine samples for LC/MS analysis. This filtration device helps to combat the significant ion suppression EtG/EtS urine analysis typically suffers from using a standa…

0.0/5.0
|0 Reviews
Request Pricing


Solid Phase Extraction Products (SPE cartridges & Well Plates) – SiliaPrep™ & SiliaPrepX™

SiliCycle Inc.

Solid Phase Extraction (SPE) is the basis of analytical laboratories. A crucial step of this process is sample preparation. Therefore we know that a clean sample will yield better results. To achieve this goal SiliCycle has designed SiliaPrep, which is a silica based sorbent exempt of fines, and SiliaPrepX, polymeric based sorbent, that can be found in cartridges, well plates and SPME (Solid Phase Micro-Extraction) cartridges…

0.0/5.0
|0 Reviews

Supel™ QuE PSA Tube

Sigma-Aldrich Supelco

“QuEChERS” (Quick, Easy, Cheap, Effective, Rugged, and Safe) - Supel™ QuE PSA Tube, pk of 50, suitable for EN 15662:2008 per BSDispersive SPE (dSPE), often referred to as the "QuEChERS" method, is an emerging sample prep technique that is becoming increasingly popular in the area of multi-residue pesticide analysis in food and agricultural products. In dSPE, food/agricultural samples are first extracted with aqueous miscible…

0.0/5.0
|0 Reviews

Supel™ QuE Acetate Tube

Sigma-Aldrich Supelco

"QuEChERS” (Quick, Easy, Cheap, Effective, Rugged, and Safe) - Supel™ QuE Acetate Tube, pk of 50, suitable for 2007.01 per AOACDispersive SPE (dSPE), often referred to as the "QuEChERS" method, is an emerging sample prep technique that is becoming increasingly popular in the area of multi-residue pesticide analysis in food and agricultural products. In dSPE, food/agricultural samples are first extracted with aqueous miscible…

0.0/5.0
|0 Reviews

Supel™ QuE Citrate Extraction Tube

Sigma-Aldrich Supelco

"QuEChERS” (Quick, Easy, Cheap, Effective, Rugged, and Safe) - Supel™ QuE Citrate Extraction Tube, pk of 50, suitable for EN 15662:2008 per BSDispersive SPE (dSPE), often referred to as the "QuEChERS" method, is an emerging sample prep technique that is becoming increasingly popular in the area of multi-residue pesticide analysis in food and agricultural products. In dSPE, food/agricultural samples are first extracted with aq…

0.0/5.0
|0 Reviews

3M™ Empore™ C8-SD Standard Well Plate

3M Bioanalytical

Functional groups, such as octyl (C8) and octadecyl (C18), can be bonded to the silica surface to provide non polar interactions.  Each of these sorbents exhibits unique properties of retention and selectivity for a particular analyte.  The choice of which sorbent is best for a particular method will be influenced by the percent recovery of analyte from the sample matrix and the cleanliness of the resulting chromatography.

0.0/5.0
|0 Reviews

3M™ Empore™ C18-SD Standard Well Plate

3M Bioanalytical

Functional groups, such as octyl (C8) and octadecyl (C18), can be bonded to the silica surface to provide non polar interactions.  Each of these sorbents exhibits unique properties of retention and selectivity for a particular analyte.  The choice of which sorbent is best for a particular method will be influenced by the percent recovery of analyte from the sample matrix and the cleanliness of the resulting chromatography.

0.0/5.0
|0 Reviews

3M™ Empore™ MPC-SD Standard Well Plate

3M Bioanalytical

This mixed phase chemistry, in which two primary modes of attraction are present, allows for a more efficient and selective extraction compared to traditional reversed phase techniques.  Neutral and ionized analytes can be simultaneously extracted from a complex mixture and eluted as separate fractions.  A mixed phase sorbent offers the following advantages: Eluting acidic and neutral analytes separately from basic analy…

0.0/5.0
|0 Reviews



3M™ Empore™ C8-SD Deep Well Plate

3M Bioanalytical

Functional groups, such as octyl (C8) and octadecyl (C18), can be bonded to the silica surface to provide non polar interactions.  Each of these sorbents exhibits unique properties of retention and selectivity for a particular analyte.  The choice of which sorbent is best for a particular method will be influenced by the percent recovery of analyte from the sample matrix and the cleanliness of the resulting chromatography.

0.0/5.0
|0 Reviews

3M™ Empore™ C18-SD Deep Well Plate

3M Bioanalytical

Functional groups, such as octyl (C8) and octadecyl (C18), can be bonded to the silica surface to provide non polar interactions.  Each of these sorbents exhibits unique properties of retention and selectivity for a particular analyte.  The choice of which sorbent is best for a particular method will be influenced by the percent recovery of analyte from the sample matrix and the cleanliness of the resulting chromatography.

0.0/5.0
|0 Reviews

3M™ Empore™ MPC-SD Deep Well Plate

3M Bioanalytical

This mixed phase chemistry, in which two primary modes of attraction are present, allows for a more efficient and selective extraction compared to traditional reversed phase techniques.  Neutral and ionized analytes can be simultaneously extracted from a complex mixture and eluted as separate fractions. A mixed phase sorbent offers the following advantages: Eluting acidic and neutral analytes separately from basic analyt…

0.0/5.0
|0 Reviews



Empore™ Accessory Filter Aid 400

3M Bioanalytical

Empore Filter Aid 400 has been shown to improve flow rates and recoveries for separation and filtration of water samples containing suspended solids.  When placed on top of the Empore™ Extraction Disk at a depth of about 1 cm, Empore™ Filter Aid 400 acts as depth filter to inhibit the migration of suspended solids to the surface of the disk.  This reduces extraction time and improves rates and recovery of analytes.

0.0/5.0
|0 Reviews

Thermo Scientific HyperSep Retain Polymeric SPE

Thermo Fisher Scientific

Versatile polymeric material for retention of polar and non-polar analytes • Exceptional recoveries for polar and non-polar analytes • High and consistent recoveries • High capacity material • Fast and easy sample preparation method development • pH stable 0-14 HyperSep Retain PEP (polar enhanced polymer) is a high purity, highly porous polystyrene DVB material modified with urea functional groups to give balanced retention of…

0.0/5.0
|0 Reviews

LiChrolut® TSC

GAT Gamma Analysentechnik GmbH (Now: NORDANTEC GmbH)

High recovery sample preparation for drug analysis and screening: LiChrolut® TSC is a selective and efficient solid phase extraction sorbent designed for clean-up of pharmaceutical products and drugs obtained from blood, plasma and urine. LiChrolut® TSC belongs to the family of the so-called “mixed-mode phases”. The combination of a reversed-phase and a cation exchange mechanism gives rise to retention of the analyte on the st…

0.0/5.0
|0 Reviews

LiChrolut® CN and NH2

GAT Gamma Analysentechnik GmbH (Now: NORDANTEC GmbH)

For reproducible sample preparation: LiChrolut® CN and NH2 are medium polar phases for solid phase extraction, which produces excellent reproducibility of sample preparation. This results a combination of high chemical stability and guaranteed capacity. LiChrolut® CN and NH2 are suitable for both polar and non-polar extractions. These medium polar phases have, in addition to a short-chained propyl-spacer, a polar functional gr…

0.0/5.0
|0 Reviews

LiChrolut® EN

GAT Gamma Analysentechnik GmbH (Now: NORDANTEC GmbH)

Highest capacity for solid phase extraction: LiChrolut® EN saves time and money in solid-phase extraction as less time is required for conditioning and drying. In addition, only a little solvent is required for elution of the analytes from the cartridge bed. The reduced quantity of solvent leads to a lower degree of contamination and to an increase in detection sensitivity. This improves the analysis of the relevant extracted…

0.0/5.0
|0 Reviews