XBridge Premier Protein SEC 250A
WatersSize-based separations of peptides, proteins, and viral vectors
Life sciences encompass a diverse range of scientific disciplines focused on the study of living organisms and their interactions with the environment. From basic life sciences (such as cell biology, genetics, immunology, and microbiology) to applied life sciences (such as disease research, multi-omics, and biotechnology), this broad field explores the fundamental processes of life and drives advancements in disease research, patient care, and our overall understanding of living organisms. Discover the endless possibilities of life sciences and their impact on shaping a healthier and more sustainable world.
Size-based separations of peptides, proteins, and viral vectors
The Thermo Scientific Ultra Agarose Spin Kit is an advanced system for isolating DNA from agarose gels using spin filters. The purified DNA can be used directly for any downstream application. Features • Ultra fast protocol: DNA is ready to use in 5–6 minutes • Low melting point agarose not required • Can be used for TAE and TBE gels • No specialised equipment required • DNA is eluted into sterile water or elution buffer (supp…
(This is the suggested replacement for 3371) Feature uniform skirt heights for greater robotic gripping surface Solvent resistant polypropylene provides compatibility with many common organic solvents (e.g., DMSO, ethanol, methanol) Certified DNase- and RNase-free Total volume is 360 µL; recommended working well volume is 75 to 200 µL Without lids; lids, sealing mats and tapes supplied separately
XBridge® and ACQUITY UPLC® Oligonucleotide C18 Columns for Synthetic Oligonucleotide Analysis and PurificationIon-pair, reversed-phase separation of detritylated oligonucleotides on sub-3 micron particles yields exceptional component resolution.UPLC ® technology increases sample throughput while maintaining necessary oligonucleotide component resolution.LC/UV and LC/MS methods for enhanced quantitative and qualitative oligonuc…
The High Yield PERformance Flask (HYPERFlask) cell culture vessel has 1720 cm2 available growth area on a polystyrene gas permeable surface. Treated for optimal cell attachment and gamma sterilized. Bar coded and compatible for use on Cell Culture Automation Platforms. Solid cap with liner on a straight neck designed for filling with growth medium. Made with USP Class VI Materials – molded and assembled in a Certified Class 1…
High binding surface is capable of binding medium (>10kD) and large biomolecules that possess ionic groups and/or hydrophobic regions Binding capacity is approximately 400 to 500ng IgG/cm2 Ideal for immunoassays Without lids, lids supplied separately Total volume is 190 µL; recommended working volume of up to 25 to 125 µL Conforms to standard microplate footprint and dimensions
Thermo-Fast Electro-Fast® Gel Systems are ideal for high throughput electrophoresis of PCR products or samples containing a small number of DNA species. When used to its full capacity, the Electro-Fast® can accommodate samples from either one 96-well microplate or two microplates (using double density combs). An additional lane in each row enables a DNA marker to be loaded in addition to all the samples from each row of a 12 x…
Spark Holland has been operating at the forefront of autosampler design for 25 years. Spark’s Reliance™ autosampler is the first true bio-injector, and is preferred by customers for 4 simple reasons: - Lowest possible carry-over- High-speed wash cycles- Low maintenance- Conditioned sample storage The Reliance™ autosampler complies with GLP requirements and can be coupled with most LC-MS systems. It runs fully integra…
8 nm bandwith, Visible single beam spectrophotometer, for fast, reliable and easy measurements.
Multi lingual, 4 nm bandwith, spectrophotometer, for fast, reliable and easy measurements.
Multi lingual, 4 nm bandwith, spectrophotometer, for fast, reliable and easy measurements.
Multi lingual, 1.8 nm bandwith, spectrophotometer, for fast, reliable and easy measurements.
Flat bottoms with 360 µL total volume Recommended working volumes of 75 to 200 µL Treated for optimal cell attachment Nonreversable lids with condensation rings to reduce contamination Sterilized by gamma radiation and certified nonpyrogenic Individual alphanumeric codes for well identification Bulk packed 10 per bag
(This is the suggested replacement for 3403) 10 µm thick translucent polycarbonate membrane Treated for optimal cell attachment Packaged 6 inserts in a 6 well plate, 4 plates per case Membrane must be stained for cell visibility
Fully automatic, temperature controlled refractometer. Measures refractive index, Brix
Product is strictly not for human use. This product is not CE marked. For Research Use Only. Not for diagnostic procedures. 20mm diameter center well holds 3 mL of medium while the outer well holds 10 mL Height is 15mm Treated for optimal cell attachment Sterilized by gamma radiation and nonpyrogenic For Research Use Only. Not for diagnostic procedures.
Hypersil Green columns allows for sharp, symmetrical and easily quantifiable assays to be developed quickly and easily. Product detail: Hypersil Green columns are developed for environmental analysis. The chromatographic separation of phenols, nitrophenols, chlorophenols, triazines, urea pesticides, phthalates and many other polar compounds requires a separating phase specially designed for the task. Hypersil Green ENV has…
o The benchmark in based deactivated silica columnso Sharp peaks and improved symmetry for basic compoundso Value and performance from a globally referenced column Product detail: DASH columns are packed to the same high standards as our analytical columns, and offer superioir chromatographic resolution in a design that eliminates the need for endfittings and wrenches during column change over. This makes column inst…
Fluophase RP Columns o A range of perfluorinated phases for alternative selectivityo Extra retention and selectivity for halogenated compoundso Select from 100Å and 300Å pore sizes Product detail:For alternative selectivity to traditional alkyl phases, we recommend you try the perfluorinated phases of Fluophase columns. The stationary phase of Fluophase RP contains a perfluorinated C6 chain, where every hydrogen atom on…
Hypersil 100 C8 Columns Compared to other classical materials, Hypersil 100 has a smaller pore diameter of only 100Å, which creates a higher specific surface area that can be advantageous where longer retention times are needed, such as chromatography of polar compounds. Product detail: Compared to other classical materials, Hypersil 100 has a smaller pore diameter of only 100Å, which creates a higher specific surface area…
The UNIGUARD drop-in cartridge fits both our guard systems: the stand alone UNIGUARD and the Direct Connection UNIGUARD. Product detail: We recommend all analytical columns are protected by a guard cartridge, which is replaced on a regular basis. The ID of the analytical column determines the correct ID for the guard cartridge. We offer 10x1.0, 10x2.1, 10x3.0, 10x4.0 (for use with both 4.0 and 4.6mm ID analytical columns) i…
RP-HPLC for Protein/Peptide Analysis and PurificationJupiter® HPLC columns offer optimized reversed phase solutions for protein and peptide characterization and purification. A wide variety of phases (C18, C12, C5, C4) and dimensions (capillary-preparative)/bulk media are available to support the majority of separation requirements.Jupiter 300 - 300 Å columns designed to purify intact proteinsJuptier Proteo - 90 Å columns eng…
QuickGel electrophoresis products are compact and easy-to-use, allowing cost effective manual separation without sacrificing quality of accuracy.
ViaLight® Plus BioAssay Kits are designed to provide unprecedented speed and sensitivity for cytotoxicity and cell proliferation studies. The ViaLight® Assay incorporates bioluminescent detection of cellular ATP as a measure of viability. Measurement of ATP is the most accurate, effective, and direct way of determining the number of living cells in culture. The ViaLight® Plus BioAssay is designed to deliver a high, stable lumi…
Setting the Standard for pH Method DevelopmentRugged reversed phase HPLC columns that offer extended lifetime under extreme pH conditions and excellent stability for reproducible, high efficiency separations. Take full advantage of high and low pH conditions (pH 1-12) to manipulate selectivity Expect longer column lifetime with patented TWIN-NX™ technology Ideal for analytical and preparative separations of basic and acid…