multi X 2500
AOX/TOX/EOX/POX/TX Analysis
Great results, ease of use. Sjajni su rezultati,jednostavnost korištenja.
SURFACE WATER. POVRŠINSKA VODA
The product is easy to use and provides very reliable results, good repeatability and accuracy. The result of interlaboratory comparative testing is very good z score= + 0.2. The support of suppliers from Croatia is very good. They are friendly and respond quickly to our call. Proizvod je jednostavan za korištenje i pruža vrlo pouzdane rezultate, dobru ponoivljivost i točnost. Rezultat međulaboratorijskog poredbenog ispitivanja je jako dobar z score= + 0,2. Podrška dobavljača iz Hrvatske je jako dobra. susretljivi su i brzo reagiraju na naš poziv.
Review Date: 19 Apr 2024 | Analytik Jena GmbH+Co. KG
Great results, simple operation, low maintenance cost.
Waste water testing, dyes testing
This euipment is very useful for testing AOX, EOX, POX in watste water, chemicals and oils. Also can be used for testing, C, N, S. Instrument can be attached to ion chromatography to determine halogens from plastics. Automate by attaching autosampler.
Review Date: 6 Jun 2020 | Analytik Jena GmbH+Co. KG
100% more output with this equipment
Made our laboratory output 100% faster
This made the output of all our pipetting and instrumentation needs improve
Review Date: 29 Nov 2016 | Analytik Jena GmbH+Co. KG
multi X® 2500 – a versatile system that opens up new dimensions in TOX analysis.
Vertical or horizontal? Are you tired of that question? Now do both with one instrument!
The innovative double furnace technology with its tilting furnace combines the advantages of both the vertical and horizontal furnace in a single analysis system. A development that sets new standards!
Simple handling, rapid operation, and minimal maintenance are just some of the many advantages the multi X® 2500 offers you. The intelligent multiWin® software guarantees fast switching between column and batch methods. Thanks to a user-friendly construction and instrument configuration it works efficiently and is easy to operate. With sophisticated sampling systems and many sample prep combinations, you can run TOX determinations either fully or partially automated.
The multi X® 2500 gives you perfectly coordinated concepts for sample preparation and analysis. Minimize downtime and increase throughput for TOX samples – you stay flexible and cost efficient.
The world’s only dual-channel system for column method enrichment – doubles both sample preparation speed and TOX sample throughput. Convenient, with no manual intervention, this system can also be used for SPE sample preparation.
The fully automated autoX sampler allows the highest sample throughput yet, in vertical and horizontal operation. Many configurations and capacities are at your fingertips! Optimize and adapt the multi X® 2500 to your laboratory’s operating requirements. The autoX series offers the right sampler for any task – from small TOX sample series in vertical mode to multi-matrix variants for vertical and horizontal sample feed in larger TOX sample series, using the column or batch method or EOX samples.
With the automatic AOX sample preparation systems of the type „APU“, you are well prepared for any type of AOX sample preparation. You can even double your sample throughput thanks to parallel enrichment provided by the fast APU 28 S. The combination of the AOX analyzer multi X® 2500, the autosampler autox 112, and the APU 28 S allows an operation with up to 112 samples in 24 hours.
All APU 28 models operate independently in day and night mode, without any manual interventions.
The multi X® 2500 is flexible and easy to operate – it offers far more than just TOX/EOX/POX analysis. Applications include determinations of TOC – important in water analysis – and chlorine content (TX/TOX) from difficult matrices. The multi X® 2500 is the analyzer to use for almost every analytical task, in any field!
Determination of total halogens in used oil
While two analytical methods and systems are necessary for the digestion in a calorimetric bomb and the subsequent detection of the halogens (e.g. by means of IC), in this application note, Analytik Jena presents a method which has the advantage of combining digestion and detection in only one analytical step in a single system.
Instrumentation and techniques for halogen analysis
In this whitepaper, learn more about the basics of halogen determination including an overview of combustion-based digestion methods and detection methods, the objectives of sum parameter analysis, and sample preparation tips and tricks.
Determination of EOX in waste and soil samples according to DIN 38414-17 and EPA 9023
This application note demonstrates that the multi X 2500 equipped with autoX 112, automatic boat drive (ABD), and flame sensor technology provides a fast, safe, and reliable solution for the analysis of extractable organically bound halogens (EOX) in soil and waste extracts.
Determining the AOX in Waste Water Using the multi X® Series Analyzers
The sum parameter ‘adsorbable organic halogen compounds’ (AOX) has been an integral part of water analysis for many years. Sewage treatment plant operators can determine the efficiency of their plant by comparing the AOX level before and after purification. This allows the operators to optimize the purification process and minimize the impact on surface water. This application note demonstrates the determination of AOX content using an analyzer of the multi X® series from Analytik Jena.
Determining Adsorbable Organically Bound Halogens in Highly Saline Waters After Solid Phase Extraction (SPE-AOX)
This application note describes a method for the determination of organically bound halogens (AOX) in samples where standard AOX methods are not applicable, for example, water with very high levels of inorganic chloride. SPE is a reliable technique used increasingly both sample preparation and purification, particularly where non- or semi-volatile analytes are present in low concentrations on complex matrices.
Determining the Total Chlorine Content in Lacquer and Paint Sludge
Chlorine is often added to lacquer or paint to increase its resistance to chemicals and harsh conditions. However, waste paint can often contaminate water, so monitoring the levels of chlorine is crucial. This application note demonstrates how the multi X® from Analytik Jena can determine not only the organically bound halogen content from samples, but the total halogen content too.