Products & ReviewSeparations

RediSep ® Gold ® C18

Purify medium to high-polarity compounds – without HPLC cost or complexity

Teledyne Labs

The supplier does not provide quotations for this product through SelectScience. You can search for similar products in our  Product Directory.

Reviews

Average Rating 5.0

|2Scientists have reviewed this product

Ease of Use
After Sales Service
Value for Money
Write your own review

Great MPLC column

 

Average Rating 5.0

Application Area:

Separation of complex mixture

Nice separation of desired product from complex mixture of compounds.

Review Date: 28 Mar 2022 | Teledyne Labs

Great separation for compounds that would be hard to purify by other methods.

 

Average Rating 5.0

Application Area:

Chromatography

Great separation for compounds that would be hard to purify by other methods, easy to use and set up. Being able to use normal or reverse phase is a great benefit. After sales team always available for any queries on how to use/set up etc.

Review Date: 10 Jun 2019 | Teledyne Labs

RediSep Rf Gold Cyano high performance columns have a cyano bound silica gel that has an intermediate polarity, between that of normal and reversed phase silica gel. This makes them a versatile tool for separation.

RediSep Rf Gold Cyano columns, when used in normal phase conditions, will perform comparably to RediSep Rf Gold normal phase silica gel using similar solvents. In reversed phase conditions, performance is similar to RediSep Rf Gold C18 Reversed-phase columns, although the elution order of compounds may be different. In summary, RediSep Rf Gold Cyano columns are a useful alternative purification media.


RediSep® Rf Gold® Cyano Features:

  • High flow rates for fast resolution of target compounds.
  • Column sizes available for purifying milligrams to several grams.
  • RFID technology for automatic set up on compatible instruments.
  • Fits all Isco CombiFlash automated organic purification instruments.
  • Long shelf life in airtight, resealable packages.
  • Luer lock end fittings.
Application NoteSeparations

Save Time and Money by Purifying Peptides Yourself

This application demonstrates how the CombiFlash® EZ Prep system with PurIon Model L mass spectrometer and RediSep® Prep columns allow research labs to save time and money by purifying crude peptides received from outside synthesis labs themselves. By purifying peptides as needed, a continuous supply of fresh peptide is always available as peptides can degrade over time during storage.


Application NoteSeparations

Purification of Delicate Compounds with RediSep Rf Gold® Diol and Cyano Columns

Many compounds are difficult to purify because they decompose on the column. This application note demonstrates the synthesis and purification of an epoxide compound with a RediSep Rf Gold Diol and RediSep Rf Gold Cyano column. The epoxide makes an excellent model for other unstable compounds as epoxides commonly decompose on silica gel. Unstable compounds are often purified using a series of liquid-liquid extractions. Purifying such compounds on a column where the amount of solvent used and evaporation is reduced is desirable.


Application NoteSeparations

Strategies to Purify Carbohydrate Based Compounds with Flash Chromatography

Carbohydrate compounds are synthesized for a variety of purposes; they are used as probes in life sciences such as mechanism studies. This application note provides a summary of methods for purifying compounds containing carbohydrate moieties and detection/fractionation of these compounds. Synthesized compounds and natural products are examined with examples from the published literature using CombiFlash® systems or RediSep® columns from Teledyne Isco.


Application NoteSeparations

Purification of Cannabimimetics and Cannabinoids for Standard Reference Materials and Forensic Analysis via Flash Chromatography

The market for synthetic cannabinoids has grown since 2008 beginning when the “spice herbal mixture” was introduced. Although the original “spice” compounds have been outlawed in many countries, renegade chemists have produced new cannabimimetic compounds that are not illegal. This application note describes how Telendyne’s Isco Combi-Flash systems and RediSep Rf Gold columns can be used to purify these new compounds for structural characterization in a forensic setting.


Application NoteSeparations

Wide Polarity Range Flash Purifications

Natural sources contain a large number of compounds that range from very non-polar materials, such as terpenes, to highly polar compounds such as tannins. Wide Polarity Range Chromatography is a method to resolve complex mixtures into various groups of molecules that are easier to purify in subsequent steps. This poster describes columns suitable for use with Wide Polarity Range Chromatography including the RediSep Gold® C18, diol, and silica and the RediSep® alumina columns.

Product Overview

Links

Buy RediSep ® Gold ® C18 Read Reviews