New Improved MPPC for General Photon Counting Applications

2 Oct 2013
Liam McNair
Administrator / Office Personnel

Product news

Hamamatsu Photonics have expanded and improved on their range of semi-conductor detectors, featuring photon counting capability, with the introduction of the brand new S12571 series of multi-pixel photon counter devices (MPPC). This new series of general purpose MPPC offers drastically reduced afterpulsing compared to previous Hamamatsu MPPC detectors.


The S12571 series are 1x1mm devices supplied in ultra-compact surface mount plastic packages, or through-hole ceramic packages. Various pixel configurations are available, with pitches of 25um, 50um and 100um and pixel numbers of 1,600, 400 and 100 respectively. Each pixel contains a quenching resistor so that simultaneous photon events can be counted separately and with a high degree of accuracy. The devices feature typical high gain values of 5.15E5 to 2.8E6, comparable to that achievable from a conventional photomultiplier tube.

Some other key areas of improvement to the MPPC include; greatly reduced dark count, reduced afterpulsing, increased photon detection efficiency, improvements in timing resolution and linearity as well as reduced crosstalk. The result of these and other improvements means that the MPPC now has a much improved signal-to-noise ratio, wider operating voltage range, improved time resolution and a wider dynamic range.

With these improvements, the S12571 series are ideal for a variety of applications, including positron emission tomography, high-energy physics, DNA sequencing, fluorescence measurement, nuclear medicine, point of care systems, drug discovery, medical diagnostic equipment and environmental analysis.

Links

Tags

Fluorescence SpectroscopyFluorometers and spectrofluorometers (also called fluorescence spectrometers) are used to measure the intensity and wavelength of fluorescent light emitted from a sample after excitation by illumination. Spectrofluorometers utilize monochromators to select the desired wavelengths, whereas filter fluorometers employ a set of filters. Spectrofluorometers for measuring steady-state fluorescence and lifetime fluorescence (or time-resolved fluorescence) are available, as well as fluorescence microscopes and microplate readers. Find the best fluorescence spectroscopy products in our peer-reviewed product directory: compare products, check customer reviews and receive pricing direct from manufacturers.Flow Cytometry / Cell CountingFlow cytometers are used to count, sort and examine multiple characteristics of cells. Other cell analysis equipment includes image cytometers, cell counters, fluorescence-activated cell sorters (FACS), magnetic-activated cell sorters (MACS), and a range of flow cytometry assay kits. Flow cytometers can reveal information on cell viability, cell proliferation, apoptosis and cell cycle progression, as well as identify cell populations and intracellular or cell-surface molecules. Additionally, some flow cytometers, known as FACS, have an additional sorting function after analysis. Cell counters and image cytometers count live and dead cell populations and can also conduct cell proliferation assays. Find the best flow cytometers, cell counters and cell sorters in our peer-reviewed product directory: compare products, check customer reviews and receive pricing direct from manufacturers.Photon Counting
New Improved MPPC for General Photon Counting Applications