Information hub for evaporation, concentration and lyophilisation

27 Nov 2007

Product news

Genevac, a world leader in evaporation technology, has announced the launch of a new information-rich website. The new website offers rapid and intuitive navigation through Genevac's comprehensive range of evaporators, concentrators and partner products, their applications and background technologies.

Designed for drug discovery applications and in use in pharmaceutical research laboratories worldwide - Genevac evaporators range from the ultra compact EZ-2 Series Personal Evaporators and the HT Systems for benchtop applications to the ultra high throughput Mega Systems for production environments. Combining ease of use, affordability and high performance the miVac concentrator range provide molecular biology laboratories with compact, efficient systems for removing water and organic solvents from a wide variety of sample formats. Partner products, from sister companies in the SP Industries Group, include freeze driers, chillers, coolers, glassware and washers.

Visitors to the site will be able to benefit from the extensive experience of Genevac staff and customers in a series of new technical forum. Updated daily, each forum offers a selection of questions and answers to common technical, applications and operational issues relating to evaporation, sample concentration and lyophilisation. Should your topic not be covered facility is given to start a new forum discussion theme.

In addition to offering access to application notes, articles and the latest news the new site provides extensive background to the technologies behind Genevac's innovative systems. Background information on the company, service and support, forthcoming events and representatives around the world is also provided.

Regularly updated, www.genevac.com is a website worth bookmarking for all laboratories involved with or interested in evaporation, concentration and lyophilisation of samples in solution.

EZ-2 Series

Genevac

Using the most advanced proven technology in evaporation science, the third generation of the EZ-2 Series has been designed specifically for solvent removal in life science research; be that concentration of samples or complete drying.  The innovative design of the EZ-2 Series presents many advantages for working in parallel within synthesis chemistry, analytical sample preparation and for general-purpose solvent removal needs in life science laboratories. At the heart of the evaporator is a solvent resistant, oil-free vacuum pump, and the high efficiency, defrost-free, SpeedTrap™, which traps all solvents as liquids, even water. Solvents collect in the insulated, plastic coated glass vessel, enabling the user to see the progress of evaporation and determine when the trap should be emptied. The EZ-2 Elite has a special auto-draining collection vessel fitted to the SpeedTrap, which uses the very powerful Scroll pump. The Elite can therefore evaporate the highest boiling solvents such as DMSO and perform the Genevac LyoSpeed fast lyophilisation method for HPLC fractions. There is a low-cost option available on the Standard, Plus and Elite that allows the routine use of hydrochloric acid and aggressive solvents. By building key elements in Hastelloy®, glass or PTFE, full protection against acid chlorides is achieved. New to the HCl Resistance option is the ability to evaporate concentrated nitric acid. This option must be specified when ordering, as it cannot be retrofitted. All EZ-2 models are resistant to routine use of high concentrations of TFA as standard. An additional option is available to allow safe operation for those wishing to use highly explosive solvents, such as pentane or diethyl ether - the inert gas purge system. This system can also be used to preserve oxygen or moisture sensitive samples under an inert gas blanket until the user returns to the evaporator. The EZ-2 Series can also accommodate a wide selection of sample holders, including round-bottom flasks up to 500ml, tubes up to 160mm long (including Dionex ASE® and Radleys Carousel tubes), custom reaction blocks, and shallow or deep-well microtitre plates. EZ-2 Series Models: The Standard (EZ-2) is suitable for water and volatile solvents The Envi (EZ-2 Envi) is recommended for concentration of volatile solvents The Plus (EZ-2 Plus) is recommended for solvents with boiling points upto 165°C The Elite (EZ-2 Elite) is recommended for solvents with boiling points upto 220°C

(4)

Links

Tags

Refrigerators Freezers and CryogenicsRefrigerators, Freezers & Cryogenics can be used for preservation or experimental purposes. Types of freezers include deep freeze, -80C°C, ultra-low temperature, explosion proof, cryogenic and controlled rate freezers. Freezing is also used in freeze-drying equipment for dehydration processes. Feature to consider in freezers include temperature control and recorders, failure alarms and self-closing mechanisms.Washing EquipmentWashing equipment is more convenient than ever before with automated systems, integrated and multi-application systems available. For instance microplate washers can be programmable, combined with reagents dispensers and used for applications such as ELISA, multiplex assays and PCR clean up.Labware and Lab SuppliesLabware and lab supplies include various forms of glassware, plasticware, reagents and personal protective equipment (PPE) and are used across all scientific laboratories, enabling daily tasks to be performed. Explore a range of flasks and beakers, petri dishes, carboys and storage bottles. Labware such as condensers, desiccators and burettes are also available for more specific tasks. Find the best labware and lab supplies in our peer-reviewed product directory: compare products, check customer reviews and receive pricing direct from manufacturers.CentrifugesCentrifuges are used to separate particulates suspended in a liquid via the application of a centrifugal force including cells, macromolecules, nanoparticles and precipitates. Centrifuges come in three sizes: microcentrifuges, benchtop and floor-standing centrifuges, depending on the volume and number of samples that require separation. When choosing a centrifuge, consider its maximum separation power indicated by its relative centrifugal force (RCF) value. Low force centrifuges reach a maximum RCF of 8,000 g, high-force centrifuges can reach maximum RCF values of 80,000 g. For extremely high forces, consider ultracentrifuges (up to 800,000 g). Refrigerated and vacuum centrifuges also known as concentrators are available for more specialized applications. A range of volumes are available for centrifuge tubes and microfuge tubes, depending on sample sizes. Find the best centrifuges in our peer-reviewed product directory: compare products, check customer reviews and receive pricing direct from manufacturers.Evaporators and Freeze DryersCentrifugal evaporation is used for solvent removal from a sample. This is a useful technique for sample concentration or sample drying. Many centrifugal evaporators are modular with a central vacuum pump for generating low pressure. Useful features of evaporators or vacuum ovens include minimal solvent bumping, solvent resistance, computer control, temperature regulation and benchtop design.
Information hub for evaporation, concentration and lyophilisation