Search results for "slas europe 2018"
Selected Filters:
Corning® 0.2-10 µL Flat Microvolume Gel-Loading Pipet Tips, Fits Gilson® Micropipettors, Natural, Nonsterile, 200 Tips/Rack, 2 Racks/Case, 400 Tips/Case
Corning Life SciencesCorning® gel-loading polypropylene pipet tips feature a flat 0.2mm thick capillary end that allows easy access into vertical and horizontal electrophoresis gels. . Please check our Technical Information Listing on our Technical Information Listing for our Pipet Tip Compatibility Guide for additional pipet tip fit information.---Working volume of 0.2-10 µL-Designed for use with Gilson® and other popular ultra-micropipettors-200…
Vials Snap Top
Agilent TechnologiesSnap Top Vials, Caps and Kits Agilent vials and caps are designed with tight dimensions guaranteed to work with Agilent autosamplers and instruments. All Agilent glass vials are made from first hydrolytical class, borosilicate glass, compliant with the requirements of U.S. and European Pharmacopeia. They are packed in a clean environment with packaging especially designed to reduce contamination. Snap top vials are the simpl…
ABgene 2.2ml Deep Well Plate
Thermo Fisher ScientificABgene 2.2ml Storage Plates are manufactured and in a class 100,000 clean room environment to ensure that each plate is contamination free. Plates are made using virgin medical grade polypropylene and have highly polished surfaces making them low binding and chemically resistant. Rigid side walls and industry standard footprint make plates suitable for automation and robotic handling, as well as for low throughput applications…
NEBNext® dsDNA Fragmentase®
New England Biolabs Inc.NEBNext® dsDNA Fragmentase® generates dsDNA breaks in a time-dependent manner to yield 100–800 bp DNA fragments depending on reaction time. NEBNext dsDNA Fragmentase contains two enzymes, one randomly generates nicks on dsDNA and the other recognizes the nicked site and cuts the opposite DNA strand across from the nick, producing dsDNA breaks. The resulting DNA fragments contain short overhangs, 5´-phosphates, and 3´-hydroxyl…
IRTracer-100 FTIR Spectrophotometer
Shimadzu CorporationCombining high speed, sensitivity and resolution with enhanced expandability and easy-to-use software, the IRTracer-100 quickly and easily obtains high-quality data for samples in such fields as pharmaceuticals, foods, chemicals and electronics. Optimized for network applications, LabSolutions IR Software features an intuitive user interface, an extensive library of spectra, and a high-performance search function. User-fri…
Prominence-i GPC System
World-class Small Multi Detection GPC System. A refractive index detector is generally used for GPC analysis of hydrophobic polymers. When trace-level additives that have UV absorption are contained in a polymer, both a UV detector and a photodiode array detector, which offers high-sensitivity detection, are used complementarily.By using the Prominence-i (PDA model), LabSolutions workstation, and LabSolutions GPC software (op…
SupelMIP® SPE - Bisphenol A
Sigma-Aldrich SupelcoThe SupelMIP SPE line consist s of highly cross-linked polymers that are engineered to extract a single analyte of interest or a class of structurally related analytes with an extremely high degree of selectivity. This is possible because selectivity is introduced during MIP synthesis in which a template molecule, designed to mimic the analyte, guides the formation of specific cavities or imprints that are sterically and chemi…
LC-8™ Centrifuge
Benchmark Scientific, Inc.Benchmark’s LC-8 series of laboratory centrifuges is uniquely designed to meet a wide range of applications in both the clinical and research laboratory. An eight position rotor is included and designed to directly accept 10ml and 15ml test-tubes (conical or round bottom), while optional adapters are also available for use with all popular sizes of blood collection and culture tubes. Unlike most compact centrifuges in this cla…
MultiMode 8 Scanning Probe Microscope
VEECO Instruments Inc.MultiMode 8 Scanning Probe Microscope from Veeco Instruments The World's Highest Resolution, Most Published SPM Just Got Better The MultiMode® 8 Scanning Probe Microscope (SPM) resets the standard for high-performance SPMs. A major advancement of the world's best-selling, most field-proven SPM platform, the MultiMode 8 SPM features two new patent-pending technologies from Veeco, ScanAsyst™ and PeakForce™ QNM™, as well as a sim…
Signals One™
Revvity SignalsMake your innovations a reality with the first unified, cloud-native SaaS R&D solution that streamlines scientific complexity and promotes collaboration.
Differential Amplifier (DP-301)
Warner Instrument Corp.The DP-301 is a single channel AC/DC differential pre-amplifier highly suited for EEG, EKG and extracellular recording. High input impedance High common mode rejection Low noise with high gain High tolerance to DC offsets Bandwidth filtering available High Input Z, High CMR High common mode rejection is very important in minimizing electrical interference. The high input resistance of the DP-301 (1012 ohm typical…
Isobutanol pure (A0433)
AppliChem GmbHBoiling point: 108°CMelting point: -108°CDensity (d 20°C/4°C): 0.80Solubility (20°C): 95 g/L (H2O)Formula: C4H10OM: 74.12 g/molCAS-No.: 78-83-1HS-No.: 29051490EC-No.: 201-148-0Storage: RTLGK: 3 ADisposal: 1R: 10-37/38-41-67S: 7/9-13-26-37/39-46hazardidentification: flammable, irritantClass/PG: 3/IIIUN-No.: UN1212WGK: 1Specification: Assay (GC): min. 98.5 %
2-Methylbutane p. A. (A0440)
AppliChem GmbHDensity (d 20°C/4°C): 0.61Boiling point: 28°CMelting point: -160°CFormula: C5H12M: 72.15 g/molCAS-No.: 78-78-4HS-No.: 29011000EC-No.: 201-142-8Storage: RTLGK: 3 ADisposal: 1R: 12-51/53-65-66-67S: 9-16-29-33-61-62hazardidentification: extremely flammable, harmful, dangerous for the environmentClass/PG: 3/IUN-No.: UN1265WGK: 1Specification: Assay (GC): min. 99.5 %
Isobutanol p. A. (A1150)
AppliChem GmbHDensity (d 20°C/4°C): 0.80Solubility (20°C): 95 g/L (H2O)Boiling point: 108°CMelting point: -108°CFormula: C4H10OM: 74.12 g/molCAS-No.: 78-83-1HS-No.: 29051490EC-No.: 201-148-0Storage: RTLGK: 3 ADisposal: 1R: 10-37/38-41-67S: 7/9-13-26-37/39-46hazardidentification: flammable, irritantClass/PG: 3/IIIUN-No.: UN1212WGK: 1Specification: Assay (GC): min. 99 %
Isobutanol for synthesis (A1246)
AppliChem GmbHDensity (d 20°C/4°C): 0.80Solubility (20°C): 95 g/L (H2O)Boiling point: 108°CMelting point: -108°CFormula: C4H10OM: 74.12 g/molCAS-No.: 78-83-1HS-No.: 29051490EC-No.: 201-148-0Storage: RTLGK: 3 ADisposal: 1R: 10-37/38-41-67S: 7/9-13-26-37/39-46hazardidentification: flammable, irritantClass/PG: 3/IIIUN-No.: UN1212WGK: 1Specification: Assay (titr.): min. 98 %
2-Methylbutane pure (A1263)
AppliChem GmbHDensity (d 20°C/4°C): 0.61Boiling point: 28°CMelting point: -160°CFormula: C5H12M: 72.15 g/molCAS-No.: 78-78-4HS-No.: 29011000EC-No.: 201-142-8Storage: RTLGK: 3 ADisposal: 1R: 12-51/53-65-66-67S: 9-16-29-33-61-62hazardidentification: extremely flammable, harmful, dangerous for the environmentClass/PG: 3/IUN-No.: UN1265WGK: 1Specification: Assay (GC): min. 99 %
Trichloroethylene for synthesis (A2516)
AppliChem GmbHMelting point: -86°CSolubility (20°C): 0.4 g/L (H2O)Boiling point: 87°CFormula: C2HCl3M: 131.39 g/molCAS-No.: 79-01-6HS-No.: 29032200EC-No.: 201-167-4Storage: RTstorage1: protected from lightLGK: 10 - 13Disposal: 2R: 45-36/38-52/53-67-68S: 53-45-61hazardidentification: carcinogenic, irritant, dangerous for the environmentClass/PG: 6.1/IIIUN-No.: UN1710WGK: 3Specification: Assay (GC): min. 99 %
Trichloroethylene p. A. (A2719)
AppliChem GmbHMelting point: -86°CSolubility (20°C): 0.4 g/L (H2O)Boiling point: 87°CFormula: C2HCl3M: 131.39 g/molCAS-No.: 79-01-6HS-No.: 29032200EC-No.: 201-167-4Storage: RTstorage1: protected from lightLGK: 10 - 13Disposal: 2R: 45-36/38-52/53-67-68S: 53-45-61hazardidentification: carcinogenic, irritant, dangerous for the environmentClass/PG: 6.1/IIIUN-No.: UN1710WGK: 3Specification: Assay (GC): min. 99.0 %
Trichloroethylene pure (A2724)
AppliChem GmbHMelting point: -86°CSolubility (20°C): 0.4 g/L (H2O)Boiling point: 87°CFormula: C2HCl3M: 131.39 g/molCAS-No.: 79-01-6HS-No.: 29032200EC-No.: 201-167-4Storage: RTstorage1: protected from lightLGK: 10 - 13Disposal: 2R: 45-36/38-52/53-67-68S: 53-45-61hazardidentification: carcinogenic, irritant, dangerous for the environmentClass/PG: 6.1/IIIUN-No.: UN1710WGK: 3Specification: Assay (GC): min. 99 %
2-Butanol Molecular biology grade (A3499)
AppliChem GmbHMelting point: -114°Cn 20°C/D: 1.3978Solubility (20°C): 200 g/L (H2O)Boiling point: 99°CFormula: C4H10OM: 74.12 g/molCAS-No.: 78-92-2HS-No.: 29051490EC-No.: 201-158-5Storage: RTLGK: 3 ADisposal: 1R: 10-36/37-67S: 7/9-13-24/25-26-46hazardidentification: flammable, irritantClass/PG: 3/IIIUN-No.: UN1120WGK: 1Specification: DNases/RNases/Proteases: not detectableAssay (GC): min. 99 %
Elecsys HE4 Assay
RocheAn immunoassay for the quantitative determination of HE4 in human serum and plasma, this test is used as an aid in monitoring the recurrence or progressive disease in patients with epithelial ovarian cancer. Serial testing for patient HE4 values should be used in conjunction with other clinical findings used for monitoring ovarian cancer. This assay is intended for use on the cobas e 411, cobas e 601, cobas e 602, Elecsys 2010…
SLB-IL60 Ionic Liquid GC column
Sigma-Aldrich SupelcoSLB-IL60 Ionic Liquid Capillary GC ColumnApplication: Modified (deactivated) version of SLB-IL59 provides better inertness. Selectivity more polar than PEG/wax phases, resulting in unique elution patterns. Higher maximum temperature than PEG/wax columns (300 ºC compared to 270-280 ºC). Excellent alternative to existing PEG/wax columns. Also a good GCxGC column choice. Launched in 2012.USP Code: NonePhase: Non-bonded; 1,12-Di(t…
The Best Labs Choose Leman Instruments
Leman Instruments SAS receive Air Monitoring Company of Choice award from Industrial Solutions














