Search results for "flow cytometry"

Results per page

25

Refine your search

Content type

Field

See more

Technique

Browse by Techniques

10000 Results Found | Selected Filters:

ProductsMaterials

Traceable Memory-Loc™ Data Logging Thermometers

Cole-Parmer Instrument Co.

Raw data is locked and may not be cleared or changed on base unit Store up to 10 unique alarm events, memory can be cleared after downloading data Smart-Alarm™ with visual/audible alarm continues to alert even if the unit returns to nonalarm conditions Triple-display—shows high, low, and current temperature simultaneously Includes NIST-Traceable certificate from our A2LA accredited (1750.01) calibration laboratory…

5.0/5.0
|1 Review


ProductsSeparations

Spectra/Por Float-A-Lyser

NBS Biologicals Ltd.

Ready-to-use dialysis device with a broad built-in range of precise MWCO's and all the needed accessory components built in for ultimate convenience.  Features leak proof and re-sealable snap-on cap for sampling, colour coded dot for MWCO, broad floatation disk for buoyancy, 6 volume-specific size, 2 membrane types- biotech grade regenerated cellulose (RC) and biotech grade cellulose ester (CE).

0.0/5.0
|0 Reviews










ProductsGeneral Lab

Laboratory Automation & Robotic System Enclosures & Cabinets

Bigneat Ltd

For protecting operators from aerosols and chemicals LAOP’s high performance airflow system draws air through the HEPA and/or carbon filtration system mounted in the roof of the enclosure. The enclosure is maintained at a slightly negative pressure with air entering the enclosure through slots at low level (>0.4m/s) and this protects the operators from aerosols and/or vapours such as solvents and DMSO released from the process…

5.0/5.0
|2 Reviews

ProductsGeneral Lab

Preddator Bulk Reagent Dispenser

Redd&Whyte

The world’s most flexible, non-contact bulk reagent dispenser. The Preddator is a low-volume, non-contact, bulk reagent dispenser that was designed and developed in close collaboration with research scientists from two major pharmaceutical companies. The Preddator now offers an unparalleled set of features and benefits to users of bulk reagent dispensers. Features & Benefits: Simple fluid pathway - Reduces dead volume…

4.7/5.0
|2 Reviews

Products

Polystyrene CellSTACK® - 40 Chamber with Vent Caps, 2 per Case

Corning Life Sciences

Has 25,440cm² cell growth area Two 26mm diameter filling ports allow direct access to chamber bottom providing greater flexibility for sterile filling and emptying by pouring, pipetting or via tubing in a fully closed system Standard 33mm threaded caps have 0.2 µm pore nonwettable membranes sealed directly to the caps to allow gas exchange Optional 33mm threaded caps are available with integrally sealed chemically resistant, h…

4.3/5.0
|1 Review


ProductsSeparations

CP-Wax 52 CB columns

Agilent Technologies

CP-Wax 52 CB GC columns have lower minimum temperature and a higher maximum temperature than non-bonded polyethylene glycol (PEG) columns due to extensive cross linking, delivering higher resolution of low-boiling-point analytes. With guaranteed reproducibility and excellent temperature stability, CP-Wax 52 CB is ideal for EPA and ASTM methods.

5.0/5.0
|1 Review

ProductsSeparations

Bond Elut PRS

Agilent Technologies

Bond Elut PRS is a strong cation-exchange sorbent that is also relatively high in polarity. With no appreciable degree of hydrophobicity, in nonpolar solvents, PRS is capable of polar and hydrogen bonding interactions. Due to the very low pKa of PRS, it is recommended for weaker cationic species, such as pyridinium compounds.

4.7/5.0
|1 Review

Brilliant II QPCR High ROX Master Mix

Agilent Technologies

Brilliant II QRT-PCR reagents were developed to maintain the high quality of our original Brilliant product line, but with a significant improvement in sensitivity of detection, ensuring reproducible quantification even at low target concentrations. With the addition of ROX reference dye to our master mix, we have streamlined the reaction setup process.

4.3/5.0
|1 Review

ProductsSeparations

Endcapped C18 - Enviro Clean® SPE Cartridges

UCT, Inc.

Endcapped C18 - Enviro Clean SPE Cartridges Enviro-Clean® cartridges are designed for use by analysts that demand a clean, dependable and rugged product for low level environmental analyses. Our EC SPE Cartridges run the gambit of our sorbents for every configuration you require. C18, Octadecyl Hydrophobic, 1000 mg/6 mL. Part # EEC181M6

5.0/5.0
|1 Review

Apostle MiniMax High Efficiency Cell-Free DNA Isolation Kit

Beckman Coulter Life Sciences

Powered by Apostle MiniMax technology, Apostle MiniMaxTM High Efficiency cfDNA Isolation Kit is an excellent tool for the isolation of ultra-low concentration cell free DNA (cfDNA). Compared to major alternative suppliers, Apostle MiniMax TM High Efficiency cfDNA Isolation Kit offers superior DNA isolation efficiency for DNA ladders spiked in different biological medium.

4.7/5.0
|1 Review

ProductsSeparations

Rtx-Wax Columns

Restek Corp.

Rtx-Wax columns are the most inert and efficient PEG columns currently available. The extended operating temperature range allows analysis of compounds having a wide volatility range and ensures low bleed at temperatures as high as 250 °C. Selectivity is comparable to other Carbowax columns for compounds of intermediate to high polarity.

4.0/5.0
|1 Review

Corning 1536-well Spheroid Microplates

Corning Life Sciences

With their novel and proprietary design, these microplates are ideal for generating and analyzing 3D multicellular spheroids in the same microplate. The Ultra-Low Attachment (ULA) surface enables uniform and reproducible 3D multicellular spheroid formation. The black opaque microplate body shields each optically clear, round bottom well from well-to-well cross-talk.

5.0/5.0
|1 Review

ProductsGeneral Lab

Horizontal Autoclave Steam Sterilizer Rectangular & Cylindrical

Bionics Scientific Technologies (P). Ltd.

Available in rectangular and cylindrical shapes Double and triple walled construction Inner tank capacity up to 240 liters or more     Single and double doors Automatic pressure locking device     Immersion type heating element Neoprene rubber gasket door seal     Automatic vacuum breaker Low water cut-off device     Hydraulic testing up to 2.5 times working pressure  

4.5/5.0
|2 Reviews

ProductsGeneral Lab

851 Titrando Coulometer

Metrohm AG

The coulometric Karl Fischer Titration is the method of choice for low level water determinations (10 μg … 10 mg absolute water content) in liquid, solid and gaseous samples. As it is an absolute method a titer determination is not necessary. With the 851 Titrando coulometric titrations are carried out straightforwardly and quickly.

4.7/5.0
|26 Reviews