GC Columns Products & Reviews

25

GC Columns

Product Filter

Explore by Field
Gas Chromatography
GC Columns
Refine your selection
Explore by Company

Ratings

Search

Selected Filters:

Agilent Select FAME GC Columns

Agilent Technologies

The Select FAME column is tuned for optimal cis/trans separations of FAMEs, especially the C18 isomers. The bonded column has an isothermal maximum operation temperature of 275°C and a programmed temperature of 290°C - a dramatic improvement of 50°C compared to non-bonded columns. Select FAME has better detection limits because the column has a very low bleed level. Even though this is a very polar column, the column efficienc…

4.5/5.0
|2 Reviews
Request Pricing


HP-5ms GC Columns

Agilent Technologies

Agilent J&W HP-5ms has very low bleed characteristics that are ideal for GC/MS. The column has excellent inertness for active compounds, including acidic and basic compounds, and improved signal-to-noise ratio for better sensitivity and mass spectral integrity.

5.0/5.0
|2 Reviews
Request Pricing

HP-FFAP Columns

Agilent Technologies

Agilent J&W HP-FFAP is designed primarily for the analysis of organic acids, free fatty acids, or samples that require quantitation of acidic impurities. The FFAP stationary phase is modified with acid to provide a very inert column that can accommodate the demanding analysis of acids dissolved in water. 

5.0/5.0
|1 Review
Request Pricing

CP-Wax 52 CB columns

Agilent Technologies

CP-Wax 52 CB GC columns have lower minimum temperature and a higher maximum temperature than non-bonded polyethylene glycol (PEG) columns due to extensive cross linking, delivering higher resolution of low-boiling-point analytes. With guaranteed reproducibility and excellent temperature stability, CP-Wax 52 CB is ideal for EPA and ASTM methods.

5.0/5.0
|1 Review
Request Pricing

CP-Sil 88 Columns for Dioxins

Agilent Technologies

Agilent J&W CP-Sil 88 for Dioxins has a very high polarity and a specific selectivity for dioxin and dibenzofuran separations. The column is supplied with an integrated retention gap to avoid problems with solvent condensation, thus allowing repeated splitless injections without phase deterioration, extending column life. 

5.0/5.0
|1 Review
Request Pricing


Agilent J&W DB-5ms and HP-5ms Ultra Inert

Agilent Technologies

Agilent ® J&W™ DB-5ms and HP-5ms Ultra Inert deliver industry-leading analytical performance in a range of chromatographic applications. Very low bleed characteristics and excellent signal-to-noise ratio and peak shapes, enables high levels of performance in analyzing challenging active analytes. DB-5ms  and HP-5ms Ultra Inert are also individually tested with a demanding Ultra Inert test probe mixture, to deliver consistent…

4.9/5.0
|8 Reviews
Request Pricing


J&W DB-FastFAME Columns

Agilent Technologies

Agilent J&W DB-FastFAME is a cyanopropyl phase engineered for the fast and selective separation of polysaturated and unsaturated FAMEs—even challenging cis and trans FAME isomers—without sacrificing the resolution generally achieved with traditional 100 meter long columns.

5.0/5.0
|1 Review
Request Pricing

DB-1ms GC Columns

Agilent Technologies

Agilent J&W DB-1ms is a nonpolar, low bleed column, with excellent inertness for acids and bases and an extended upper temperature limit. Using low bleed stationary phases in DB-1ms reduces column contribution to background noise, resulting in a higher signal-to-noise ratio and better sensitivity. 

4.5/5.0
|12 Reviews
Request Pricing

Rtx®-1 Columns

Restek Corp.

Rtx®-1 columns exhibit long lifetime and very low bleed at high operating temperatures. A proprietary synthesis process eliminates residual catalysts that could cause degradation and increase bleed. • General purpose columns for solvent impurities, PCB congeners (e.g. Aroclor mixes), simulated distillation, drugs of abuse, gases, natural gas odorants, sulfur compounds, essential oils, hydrocarbons, semivolatiles, pesticides,…

4.7/5.0
|10 Reviews
Request Pricing

GCxGC Columns

Restek Corp.

• Wide range of stationary phases offers orthogonal separations. • High thermal stability maximizes system ruggedness and sensitivity. • Unrivaled column inertness for accurate analysis of active compounds. • 0.15, 0.18, and 0.25 mm ID formats accommodate varying sample capacities, speeds, and detectors. • Secondary columns come in convenient 2 m lengths for economical method development. GCxGC is a powerful multidimensional G…

4.9/5.0
|2 Reviews
Request Pricing

Rtx®-BAC Plus 2 Columns (fused silica)

Restek Corp.

- Optimized column selectivities guarantee resolution of ethanol, internal standards, and frequently encountered interferences. - Robust and reproducible column chemistry ensures longer column lifetime and consistent results. - 2 minute analysis time increases lab productivity. - Stable to 260 °C Don’t forget: Blood alcohol analysis requires dual column confirmation when using GC/FID.

5.0/5.0
|2 Reviews
Request Pricing

Rtx®-VMS Columns

Restek Corp.

Rtx®-VMS Columns (fused silica) (proprietary Crossbond® phase) • Application-specific columns for volatile organic pollutants by GC-MS • Complete separation of U.S. EPA Method 8260B compounds in less than 10 minutes • Stable to 260 °C • No known equivalent phases

4.8/5.0
|3 Reviews
Request Pricing

Rtx®-Volatile Amine Columns

Restek Corp.

The Rtx®-Volatile Amine column was designed specifically for analyzing volatile amines in difficult matrices, such as water. The unique base deactivation creates an exceptionally inert surface for these sensitive compounds, resulting in highly symmetrical peaks which allow low detection limits. The stable bonded phase yields a column that is not only retentive and highly selective for these compounds, but is also very robust…

5.0/5.0
|1 Review
Request Pricing

MXT®-Biodiesel TG Columns

Restek Corp.

Restek has raised the bar with a new high-temperature MXT®-Biodiesel TG column line to complement their fused silica column line for biodiesel analysis. These new MXT® -Biodiesel TG columns are stable to 430°C and offer unique retention gap options that minimize dead volume and leaks. Choose either a 0.32mm column factory-coupled to a 0.53mm retention gap, or select a single unit 0.53mm column featuring Integra-Gap™, a built-…

5.0/5.0
|2 Reviews
Request Pricing

Rxi®-PAH Columns

Restek Corp.

The Rxi®-PAH GC columns were designed by Restek with a higher phenyl-content stationary phase that provides unique selectivity to separate important polycyclic aromatic hydrocarbons (PAH) for food safety that cannot be distinguished by mass spectrometry. Even difficult priority compounds, such as the European Food Safety Authority (EFSA) PAH4, are easily separated and accurately quantified, results that cannot be achieved on…

4.5/5.0
|2 Reviews
Request Pricing

Rtx®-CLPesticides Columns

Restek Corp.

Improved resolution and faster analyses, compared to 1701 or phenyl phases, make these the pesticide columns of choice. Rtx®-CLPesticides columns are specially designed to overcome the coelutions and analyte breakdown typically encountered in chlorinated pesticide analyses for EPA Methods 8081, 608, and CLP. By achieving baseline resolution of the 20 target analytes, more accurate qualitative data can be obtained, providing r…

4.7/5.0
|4 Reviews
Request Pricing


Rtx-5 (G27) Columns (Fused Silica)

Restek Corp.

Low-polarity phase; Crossbond diphenyl dimethyl polysiloxane General-purpose columns for drugs, solvent impurities, pesticides, hydrocarbons, PCB congeners (e.g., Aroclor mixes), essential oils, semivolatiles. Equivalent to USP G27 and G36 phases. Temp. Limits: -60 to 325/340 °C Similar To: Agilent 122-5033, 19091J-233; Phenomenex 7HG-G002-22; Varian CP8771; Grace 13657, 5121840, 8635223 Le…

5.0/5.0
|4 Reviews
Request Pricing



Rtx-624 Columns (fused silica)

Restek Corp.

A low- to midpolarity phase application-specific columns for volatile organic pollutants. Recommended in U.S. EPA methods for volatile organic pollutants. Temperature range: -20 °C to 240 °C. Equivalent to USP G43 phase. The unique polarity of the Rtx-624 column makes it ideal for analyzing volatile organic pollutants. Although the Rtx-502.2 column is recommended in many methods, the Rtx-624 column offers better resolution…

5.0/5.0
|2 Reviews
Request Pricing

Rtx®-1301 (G43) Columns

Restek Corp.

A low- to midpolarity phase general-purpose columns for residual solvents, alcohols, oxygenates, and volatile organic compounds. Equivalent to USP G43 phase.   Many analysts feel the Rtx-1301 column has the best cyanosiloxane bonded stationary phase available, with no other column manufacturer providing lower bleed, longer lifetime, or better inertness. The polymer is fully characterized to ensure long-term reproducibili…

5.0/5.0
|1 Review
Request Pricing