Amine-Reactive (AR) Probes
Gator BioCovalently bonded to amine groups on proteins. Recommended for use in kinetics measurements and indirect quantitation experiments. This biosensor uses EDC/NHS activation and coupling to link proteins.
Biosensor Systems, Automated
Covalently bonded to amine groups on proteins. Recommended for use in kinetics measurements and indirect quantitation experiments. This biosensor uses EDC/NHS activation and coupling to link proteins.
Used to bind hydrophobic proteins or to create custom-made biosensors.
The Gator ® Ni-NTA probes enabler rapid and continuous quantification of His-tagged proteins without the need for Ni2+ recharging. The stable immobilization of His-tagged proteins allows for facile kinetics analysis with binding partners, off-rate screening, and epitope binning of antibodies experiments.
Gator Bio offers many on-demand probes such as Anti-RBD SARS-COV-2; Anti-Rabbit; Anti-Rat; Anti-Flag
The Gator ® AAV9 Probes are high specificity nanobody-based biosensors that enable direct capture and quantitation of AAV9 in crude lysates, column eluates, cell lysates and cell culture supernatants. The Gator ® AAV9 probe uses proven CaptureSelect™ (Thermo Fisher Scientific) high affinity and high specificity anti-AAV9 nanobody.
HFCII probes are high-performance nanobody-based biosensors that can detect and quantitate human IgG and its isotypes in different buffers (Q, K), cell culture supernatant, cell media, and other crude samples. Dynamic range: 0.3-6000 µg/mL in Q buffer; 1-2000 µg/mL (in diluted cell culture media).
The Gator ® High Sensitivity (HS) AAV9 Kit enable high sensitivity quantification of AAV9 in crude and purified samples. The HS AAV9 Kit includes: HS AAV9 probes (96 probes/tray) HS AAV9 Detection Solution AAV Amplification Solution AAV Substrate Solution AAV Substrate Diluent Q Buffer ** Contains temperature sensitive components. Must be shipped overnight. ** *Not compatible with Gator ® AAV9 probe (Part No. 160021)
Streptavidin probes for kinetic analysis of a wide range of biomolecules such as peptides, proteins, and large lipid nanoparticles.
Extending walk-away time while delivering fast, reproducible and high-quality data The Gator ® Pro instrument is designed for fast, automated, high-throughput analysis. 32 spectrometers enable high frequency parallel measurement of up to 32 samples. 3 sample plates enable automated data acquisition of 1152 samples per batch.
Binds biotinylated proteins with near covalent linkage. Sensor can be fully reactivated over 20+ times. Kit includes: 24 Flex SA probes 3 bottles of priming reagent (50mL/bottle) 1 bottle of Capture reagent (20mL/bottle) 1 bottle of reactivation reagent (20mL/bottle) 1 bottle of K buffer (30mL/bottle) Plate foil
High-capacity streptavidin biosensors to be used for measuring small molecules and peptides binding to protein targets. Intended for affinity measurements of small molecule or peptide binding to a biotinylated (or AviTag containing) biomolecule.
Ni-NTA Regen and Ni-NTA Neutral Buffers allow for continuous regeneration of the Ni-NTA (i.e., Tris-NTA and charged with Ni2+ ions binding to His-tagged proteins) probes, without the need for an additional Ni2+ recharging step. Is used for regeneration up to 20 times, with no loss in binding rate.
Ni-NTA Regen and Ni-NTA Neutral Buffers allow for continuous regeneration of the Ni-NTA (i.e., Tris-NTA and charged with Ni2+ ions binding to His-tagged proteins) probes, without the need for an additional Ni2+ recharging step. Is used for regeneration up to 20 times, with no loss in biding rate.
Includes reagent set for reactivating the Flex SA probe. Kit includes: 3 bottles of priming reagent (50mL/bottle) 1 bottle of Capture reagent (20mL/bottle) 1 bottle of reactivation reagent (20mL/bottle) 1 bottle of K buffer (30mL/bottle) Reactivate probes over 20+ times
Used to gently strip sample from various biosensors to enable reuse. Regen Buffer No Salt (PN: 120063) is compatible with many Gator ® biosensors, including HFCII, MFC, FAB, AAVX, and AAV9.
The Gator ® HS AAV Kit enable high sensitivity quantification of AAV serotypes 1-8, 10 and chimeric serotypes in purified and crude samples. The HS AAV Kit includes: HS AAV Probes (96 probes/tray) HS AAV Detection Solution AAV Amplification Solution AAV Substrate Solution AAV Substrate Diluent Q Buffer ** Contains temperature sensitive components. Must be shipped overnight.…
Version 2.10 of GatorOne is intended to operate the Gator ® instrument.
The Gator ® AAV Ratio Kit enables empty vs full determination of AAV serotypes 1-10 and chimeric serotypes in crude and purified samples. The AAV Ratio Kit includes: AAVX probes (96 probes/tray) SSB probes (96 probes/tray) Lysis Buffer DNA Detection Solution AAV Ratio Substrate Q Buffer SS DNA Standard Lysis tubes ** Contains temperature sensitive components. Must be shipped overnight. **
Gator Bio’s Strep-Tactin XT probe is coated with Strep-Tactin ® XT that binds Twin-Strep-tag ® with pM affinity making it an ideal tool for quantitation and kinetic analysis of Twin-Strep-tag fusion proteins.
Gator Bio’s Anti-PEG probe is coated with anti-PEG antibody designed for quantitation and kinetics analysis of PEGylated Lipid Nanoparticles and Liposomes.
Implementing BLI in Academia and Industry Made Easy The Gator ® Pilot instrument is designed for low-throughput analysis. 4 spectrometers enable high frequency parallel measureme.
Achieve high-quality data for both thermally unstable proteins as well as extended assay times The Gator® Pivot instrument is designed for intermediate-throughput analysis. 16 spectrometers enable high frequency parallel measurement of up to 16 samples. It is also equipped with temperature and evaporation control that alleviates concerns about analyzing thermally unstable proteins and the risk of sample evaporation during ext…