Thermo Scientific Exactive Plus Orbitrap LC-MS
The Exactive Plus Orbitrap LC-MS is a benchtop full scan mass spectrometer designed for compound identification and high-throughput, high-performance screening. The Exactive Plus delivers high resolution accurate mass (HRAM) data and fast, reproducible results for qualitative and quantitative analysis. The availability of HRAM and full scan capability gives you all the data, all the time. It allows retrospective data analysis…

The supplier does not provide quotations for this product through SelectScience. You can search for similar products in our Product Directory.
One of the best instrument for unknown analysis for metabolomics and proteomics
Metabolomics
High quality LCMS, easy to use and can be apply for unknown identification and also quantification
Review Date: 27 Mar 2023 | Thermo Fisher Scientific
Great results
Metabolomics
Easy to use
Review Date: 22 Oct 2022 | Thermo Fisher Scientific
Quality instrument for high quality data
Analyze exosome protein profile
Gain quality results without too many glitches, less chance to get clotted, consistent results, and quick service wait time
Review Date: 28 Sept 2022 | Thermo Fisher Scientific
Lot of applications and easy to use software
Dereplication of plant metabolites
Xcalibur software is very easy to use. A lot of resources for learning how to use it is free and a lot of applications from a lot of labs have been developed. Raw data ready to use with free softwares for their analysis
Review Date: 28 Sept 2022 | Thermo Fisher Scientific
Great results
Drugs
Excellent
Review Date: 17 Jul 2022 | Thermo Fisher Scientific
I like it
Natural products discovery
I like working on LC-HRMS from Thermo Fischer Scientific
Review Date: 21 Jan 2022 | Thermo Fisher Scientific
The best ultra-high-resolution table top mass spectrometer!
metabolomics
In my opinion, this is the only best ultra-high-resolution table top mass spectrometer. Further, the software provided by Thermo makes the instrument easy to operate.
Review Date: 22 Dec 2021 | Thermo Fisher Scientific
Great product.
Forensic toxicology
Great product, Accurate.
Review Date: 25 Jul 2021 | Thermo Fisher Scientific
Great technology.
Drug Analysisa
Great technology, good reproducible results.
Review Date: 24 Jul 2021 | Thermo Fisher Scientific
Best mass spec on the market.
Metabolomics and lipidomics
Most reliable mass spectrometry instrument. The mass accuracy provided is a must when used for metabolomics and lipidomics. Customer service is outstanding.
Review Date: 15 Jul 2021 | Thermo Fisher Scientific
The Exactive Plus Orbitrap LC-MS is a benchtop full scan mass spectrometer designed for compound identification and high-throughput, high-performance screening.
The Exactive Plus delivers high resolution accurate mass (HRAM) data and fast, reproducible results for qualitative and quantitative analysis.
The availability of HRAM and full scan capability gives you all the data, all the time. It allows retrospective data analysis and eliminates MS method development leading to improved and simplified analytical throughput.
Exactive Plus is easy-to-use, cost effective to operate and coupled with workflow-driven software, makes an ideal instrument for new users in routine analytical laboratories.
Selected benefits of the Exactive Plus are specified below:
- High Resolving Power
- (up to 140,000) - Eliminates isobaric interferences to increase confidence for analysis or complex samples
- Mass accuracy - Better than 1ppm in full scan and AIF scan using fully automated AGC and mass calibration procedures offers confident identification
- U-HPLC Scan Speed - The 12Hz scanning frequency of Exactive Plus is fully compatible with U-HPLC and ensures exact mass measurement for fast chromatography applications
- Fast Polarity Switching - A full cycle of 1 positive and 1 negative scan is performed within 1 second at a resolution setting of 35,000 without sacrificing mass accuracy
- All-Ion-Fragmentation (AIF) - With multiple dissociation techniques; in source collisional induced dissociation (CID) and high energy collisional dissociation (HCD), provides MS and MS/MS data
- Full MS scan, AIF scan, data dependent AIF, alternating Full MS and AIF scan
- Intuitive software interface
The Exactive Plus Orbitrap LC-MS is ideal for the following applications:
- Environmental and Food Safety
- Clinical Research
- Forensic Toxicology
- Drug discovery, metabolism and pharmacokinetics (DMPK)
- Metabolomics
- Pharmaceutical
- BioPharma – Intact Protein analysis
Laboratories analyzing food, pharmaceuticals, neutraceuticals, and other complex samples can now purchase Exactive Plus LC-MS system equipped from the factory with IonSense ID-CUBE™ ion sources. This configuration is designed to minimize the need for sample preparation to simplify and speed analyses.
Uncover new dimensions of isotope ratio analysis with Thermo Scientific Orbitrap MS technology
Isotope ratio mass spectrometry (IRMS) is a powerful tool for determining subtle isotopic variations within a sample and works by breaking down complex molecules in simple gases. This technique can provide unique insights however important intramolecular isotopic information is often lost.
Explore a new, comprehensive approach to IRMS using electrospray ionization (ESI). Thermo Scientific™ Orbitrap™ MS technology gives access to a wide range of isotopic information from a variety of polar compounds in liquid samples. In contrast to classical IRMS methods, Thermo Scientific™ Orbitrap Exploris™ Isotope Solutions enable the calculation of isotope ratios directly from the relative abundances of the compounds isotopologues, measured as intact molecular ions.
Food contact materials
Various food contact materials are used throughout the food chain and can give rise to migration (leaching) where chemical substances and metals can transfer to foods. Regulations are complex but a diversity of analytical techniques provide effective tools for monitoring and control. In this white paper, Thermo Fisher Scientific reflects on the current state-of-the-art in terms of types of food contact materials in use and problems which have come to light in terms of migration and safety of food.
Food and beverage resource guide for commercial food testing laboratories
From food safety analysis and nutritional testing, to chemical analysis for food quality and food integrity, Thermo Fisher Scientifics's portfolio of application notes demonstrates how its chromatography, trace elemental, and mass spectrometry systems aim to deliver data that is compliant with regulations.
Building quality assurance and quality control guidelines for metabolomics and lipidomics
In this application note, discover how Thermo Fisher Scientific has collaborated with the scientific community to develop novel metabolomics solutions that combine Thermo Scientific™ Orbitrap™ LC-MS instruments with data analysis software and libraries.
Unmasking the rising threat of mycotoxins in the global food and feed supply chain
In this infographic, we explore how a rise in global temperatures due to climate change could mean countries in cool or temperate climates are more at risk for mycotoxin contamination in food and animal feed supply chains. Discover insights into legislation, global prevalence, socioeconomic impacts, and how manufacturers are innovating to help institutions optimize their testing capabilities to comply with international trade regulations and ultimately, ensure food safety.
Tackling the residual problem of pesticides: A challenge in the global food supply chain
Residual pesticide testing is an important factor in ensuring global food safety and improved nutrition. In this informative infographic, we explore the international impact of the pesticide problem, socioeconomic risks involved in pesticide use, what can be done, and how scientists can streamline their path to multi-residue testing.
A New Lipid Software Workflow for Processing Orbitrap-based Global Lipidomics Data in Translational and Systems Biology Research
This poster presents a new workflow for high-resolution Thermo Scientific™ Orbitrap™-based mass spectrometers for lipidomics using a model system consisting of a wild-type strain vs. knockout for Co-Q production in yeast.
Multi-Mycotoxin Screening and Quantitation Using UHPLC, High Resolution and Accurate Mass
In this poster, read about a method for analyzing 32 mycotoxins in beer. The multi-mycotoxyin assay is based on very simple sample preparation and ultra high performance liquid chromatography coupled with full spectral Orbitrap™ MS detection.
High Throughput Screening in Drug Discovery for Cancer Research Peptides Using High Resolution LCMS
Lead discovery groups are constantly developing new methodologies to screen large chemical libraries against a specific target. The majority of these methods utilize plate reader devices, ELISA, and other analytical techniques that are amenable to high throughput analysis. Existing analytical methodology used for screening can be less than ideal due to sample prep considerations, limit of detection, and specificity of analyte detection. In this application note read high resolution LCMS can provide a high quality alternative while maintaining a sampling rate that is suitable for HTS requirements.