Thermo Fisher Scientific Introduces New Mass Spectrometry Systems, Software and Workflow Solutions at ASMS 2009

31 May 2009
admin admin
Consultant

Thermo Fisher Scientific Inc., the world leader in serving science, today announced it is launching two new breakthrough mass spectrometers at ASMS 2009, the Thermo Scientific LTQ Velos and LTQ Orbitrap Velos.

The LTQ Velos features an innovative dual-pressure trap and advanced ion optics, making it the world's fastest and most sensitive linear ion trap mass spectrometer. The LTQ Orbitrap Velos combines the new Velos technology with the industry-leading Orbitrap mass analyzer and a new Higher-Energy Collisional Dissociation (HCD) cell to deliver ultra-high resolution and accurate mass data.

These systems can be seen at Thermo Scientific booth 99 or the Thermo Scientific hospitality suite at the Philadelphia Marriott Downtown in Salons G-K during the conference, which runs from June 1-4. In addition, Thermo Fisher Scientific is introducing eight other mass spectrometry solutions designed to deliver better analytical performance and greater ease of use in a broad range of applications.

"These new MS instruments give our customers a huge advantage in resolving the high levels of analytical complexity they find in areas like proteomics and metabolism," said Dr. Ian Jardine, vice president of global research and development for Thermo Fisher Scientific. "The outstanding data quality and sensitivity of the LTQ Velos make it ideal for analyzing complex mixtures, such as identifying low level proteins and structural elucidation of metabolites. Similarly, the high mass accuracy of the LTQ Orbitrap Velos increases the speed and confidence of protein identification in complex samples by minimizing false positives."

Featured new technologies at ASMS include:

• Thermo Scientific LTQ Velos - A unique dual pressure trap technology features two discrete pressure regions that allow the decoupling of ion manipulation and detection. This enables the utilization of optimal pressures during analysis, increasing both scan speed and resolution. The LTQ Velos can be upgraded to the LTQ Orbitrap Velos, allowing laboratories to extend their initial investment to include accurate mass and ultra-high resolution capabilities with no compromise to sensitivity and speed of analysis.

• Thermo Scientific LTQ Orbitrap - The new HCD cell in the LTQ Orbitrap Velos is more efficient, resulting in improved quantitation of isobarically-labeled peptides, such as applications requiring tandem mass tags (TMT). Electron Transfer Dissociation (ETD) generates complementary information for highly sensitive PTM analyses and de novo sequencing. Additionally, the system's ultra-high resolution delivers certainty in analytical results by enabling molecular weight determination for intact proteins and in-depth analysis of isobaric species.

• Thermo Fisher is also introducing two new products designed to increase the productivity of quantitative proteomics research. The products are Intelligent Selective Reaction Monitoring (iSRM), which improves the throughput of SRM assays and Pinpoint software, for automated method development and quantitative analysis of SRM-based targeted peptide assays.

• Thermo Scientific Watson LIMS 7.4 - The newest version of this popular LIMS software now includes a built-in data interchange with the company's TSQ Series mass spectrometers, allowing for direct data acquisition, peak integration and re-integration, storage, archiving and reporting of raw data, all under the control of Watson's centralized Oracle database repository.

• Thermo Scientific Mass Frontier 6.0 - The new version of this powerful software package offers many sophisticated features for the management, evaluation and interpretation of MSn spectra. The software is applicable to small molecule structural elucidations in a wide range of applications, including metabolite identifications and impurity analysis in pharmaceutical and toxicology studies.

• Thermo Scientific TSQ Quantum Access MAX triple-stage quadrupole mass spectrometry system and TraceFinder software - This complete workflow solution for food and environmental safety testing helps laboratories meet increasingly stringent monitoring requirements, simplify analysis and boost productivity. This system performs structural confirmation and library matching, enabling it to confirm and quantitate hundreds of compounds in a single experiment.

• Thermo Scientific Accela 600 Pump - Designed for high flow rate applications, this pump provides accurate and precise flow and gradients under all operating pressure conditions with minimum pulsation. A delay volume of only 90 µL reduces pump equilibration and system cycle times. The Accela 600 Pump provides quaternary capabilities with flow rates up to 5 mL/min and a maximum operating pressure of 600 bar.

For more information about our mass spectrometry solutions, please visit Thermo Scientific booth 99 or the Thermo Scientific hospitality suite at the Philadelphia Marriott Downtown in Salons G-K during ASMS 2009.

Thermo Scientific LTQ Orbitrap XL ETD

Thermo Fisher Scientific

The Thermo Scientific LTQ Orbitrap XL ETD is the most powerful instrument for proteomics analyses: It combines three different and complementary fragmentation techniques CID, HCD, and ETD with the proven benefits of Orbitrap technology. It is the most comprehensive solution for complex PTM analysis, intelligent sequencing of peptides, top-down and middle-down analysis, and protein quantitation via stable isotope labelling such as iTRAQ or label-free quantitation.

(6)

Thermo Scientific LTQ Orbitrap XL

Thermo Fisher Scientific

Thermo Scientific LTQ Orbitrap XL - The Most Confident Protein Identification The Thermo Scientific LTQ Orbitrap XL hybrid FTMS (Fourier Transform Mass Spectrometer) supports a wide range of applications from routine compound identification to the most challenging analysis of low level components in complex mixtures. The LTQ Orbitrap XL is based on the fast and highly sensitive Thermo Scientific LTQ XL linear ion trap and the patented Orbitrap* technology. The LTQ Orbitrap XL features a new HCD collision cell for ultimate flexibility in fragmentation experiments for advanced proteomics and small molecule research. Key features of the Thermo Orbitrap XL include: Outstanding Mass Accuracy, Resolution, Dynamic Range and Sensitivity • Featuring the new HCD collision cell for ultimate flexibility in fragmentation experiments for advanced proteomics and small molecule research • Superior mass accuracy for lower false positive rates (FPRs) • Parallel acquisition mode for optimized productivity From Protein ID to Biomarker Discovery with the Thermo LTQ Orbitrap• Excellent sensitivity and fragmentation efficiency • Reliable identification and quantitation in one experiment High quality data from the LTQ Orbitrap XL for reliable de novo sequencing • Superior mass accuracy and high resolution leading to confident de novo sequencing results • Multiple collision modes (CID and HCD) for comprehensive structural information

(28)

Thermo Scientific LTQ Velos Dual-Pressure Linear Ion Trap

Thermo Fisher Scientific

Building on a strong tradition of innovation, the Thermo Scientific LTQ Velos provides significantly enhanced performance for complex sample analyses. The revolutionary dual-pressure ion trap and S-Lens ion optics combine to deliver increased ion transmission along with greater efficiency of ion trapping and fragmentation. The result is the fastest and most sensitive ion trap for virtually all applications. The LTQ Velos™ is the latest evolution in the award winning LTQ family of linear ion trap mass spectrometers. It offers significant improvements in data acquisition rate, sensitivity, and mass resolution. S-lens ion optics increase ion transmission and shorten trap fill time, improving instrument sensitivity and data acquisition rate More efficient dual-pressure ion trap simultaneously increases scan speed and mass resolution Predictive Automatic Gain Control reduce cycle times, yielding improved data acquisition rates Improved sensitivity and mass resolution increase confidence in identification of low-level analytes Increased performances enables simultaneous identification, structural elucidation, and quantification of complex samples Upgradeable to the ultra-high resolution and outstanding mass accuracy of OrbitrapTM technology

(3)

Tags