INTEGRA Introduces New Three Position Stage to Optimize Workflow with 96- & 384-well Microplates

2 Dec 2014
Sarah Thomas
Associate Editor

INTEGRA has introduced a Three Position Stage for its VIAFLO 96 and VIAFLO 384 handheld benchtop pipettes. The new accessory expands available stage positions for microplates, reservoirs and tips on a VIAFLO 96 or VIAFLO 384 from 2 to 3 thereby enhancing workflow in a wide range of applications. Beneficially the Three Position Stage also features an indexing function to allow access to 384-well plates using a 96-channel pipetting head.

For plate replication applications - having a tip rack on the left position, the source plate on the middle position and the target plates on the right position of the Three Position Stage enables the user to replicate the source plate with minimal plate handling effort. Changing tips and target plates can be done without moving the source plate, eliminating the risk of spills.

When undertaking compound dilutions or screening – the Three Position Stage enables accurate and rapid addition of reagent and compounds from 2 different sources (reservoir and plate) to one target screening plate.

Easily installed on a new or existing VIAFLO 96 or VIAFLO 384 the new accessory reduces the need for plate handling thereby minimising errors and improving workflow.

The VIAFLO 96 / 384 offers high sample throughput without a robot. It is a handheld benchtop pipette, capable of 96- and 384-well pipetting with a choice of various pipetting heads. The VIAFLO 96 benchtop electronic pipette offers an affordable solution to increase productivity when working with microplates. It closes the gap between traditional manual pipettes and robotic systems, allowing for accurate and reproducible 96-channel pipetting. The VIAFLO 384 is a more advanced system, which can work with both 96- and 384-channel pipetting heads to maximize productivity. It features the same footprint and intuitive user concept as VIAFLO 96.

GripTips for VIAFLO 96/384

INTEGRA Biosciences

When working with a 96- or 384-channel system such as the VIAFLO 96/384, it is essential that the pipette tips are reliably attached. Due to the unique design, the GripTip system ensures that the tips will never accidently fall off, even when performing a tip touch on the sidewall of a vessel. Pipetting with multiple channels into a well plate is a precision task. GripTips for VIAFLO 96/384 undergo an additional quality check for tip straightness, guaranteeing accurate pipetting in 96- and 384-well plates. Depending on the tip size, GripTips are packaged in two different tip boxes. Larger volume GripTips (300 µl, 1250 µl) are delivered in boxes of 96 tips. The smaller volume GripTips (12.5 µl, 125 µl) are filled in a space efficient 384-fold grid in XYZ boxes. These boxes house 4 times as many tips and feature the standard SBS-footprint. All tips are available in non-sterile, sterile or filtered sterile configuration. Features and benefits: • GripTips snap onto the tip fitting of the pipetting head, which prevents tips from falling off. • An additional quality check ensures that pipette tips are perfectly straight, enabling precise pipetting in multi well plates. • Filtered GripTips reliably protect the pipetting head against contaminations caused by aerosols.