How to overcome challenges and improve your semivolatile organic compound analysis

Watch this on-demand webinar to explore specific challenges of SVOC analysis and how to overcome them

10 Jan 2023
Blake Forman
Content Creator

Expert insights

How to overcome challenges in your semivolatile analysis on-demand webinar

Semivolatile organic compound (SVOC) analysis can be tough. When analyzing acidic, basic, or neutral compounds, you need a column with a balanced, highly inert deactivation that is also rugged enough to withstand repeated injections of challenging matrices, such as wastewater and hazardous waste extracts.

In this free on-demand SelectScience® webinar, discover how the Rxi-SVOCms columns were designed and built from the silica surface up to perform reliably and consistently under the harshest testing conditions. Whether it is PAH analysis in under 10minutes or a wide calibration range for routine 8270 analysis, there is an Rxi-SVOCms column to meet all needs.

Key learning objectives

  • Learn how the specific challenges of SVOC analysis were used to guide development of the Rxi-SVOCms
  • Examine how the inertness of the column impacts sensitive analytes
  • See how the column performs over time and how routine maintenance restores performance
Watch on demand

Read on for highlights from the live Q&A session, or watch the webinar on-demand, at a time that suits you.

Do you recommend using a guard column when running dirty samples?

Restek: We've found during testing and development that the performance holds up fairly well with a large amount of the column cut away eventually. When you're using a guard column, you run the risk of leaks damaging the stationary phase with whatever union you're using to couple the guard to the analytical column. I suppose the only times when I would recommend it would be for large volume injection to improve the peak shape, so you don't have solvent flooding the analytical column.

If you don't like your retention times moving around from trimming, you can use a sacrificial piece of the analytical column from another column and replace, I suppose the head of the column in 2-m or 3-m segments, so that your peaks all stay in the same place most of the time.

Are any of the Rxi-SVOCms columns manufactured with an integrated guard?

Restek: They are not. It's possible that we will release something in the future, as the technology behind the column doesn't prevent it. However, with an integrated guard, there's some migration of non-volatile or really low-volatility material from the head of the column down through the deactivated tubing or the retention gap to the head of the analytical column. As a result, you end up having to remove the integrated guard, and trimming the head of the column, and then reattaching the guard. That's one of the reasons why we opted not to go forward with the integrated guard for this application.

Is the column good for benzoic acid and Kepone® analysis?

Restek: The column works very well for a large group of pesticides that are generally considered troublesome by GC because they're rather reactive. Kepone is one where it shows a very good response with minimal degradation. Benzoic acid isn't really soluble in any GC phase. That's why it shows up more as that smear than a peak. But yes, the column is inert enough that you can get a linear calibration with benzoic acid. It's just not going to look very good.

Can I run this column with hydrogen as the carrier gas?

Restek: Yes. The hydrogen limitation more comes from the instrument manufacturer or the instrument’s capabilities. I'm only familiar with Agilent's mass spec when it comes to hydrogen. Your source assembly should have a serial number on the magnet or the serial number has to be beyond a certain number. I would suggest checking with the manufacturer before running hydrogen, but the column itself is compatible with hydrogen and nitrogen as carrier gases.

If you are trying ultra-low-level PAHs by SPME Arrow techniques with both immersion and headspace methods, will the new column phase help in achieving recoveries above 80% for analytes such as indeno, dibenzo, and benzo GHI anthracene?

Restek: I suspect that the poor recovery has more to do with the desorb settings for the injection using the arrow. The column shouldn't really have anything to do with that. I would play around more with the preheating before doing the desorb, possibly even incorporating some labeled deuterated PAHs to use as isotope dilution standards to correct for the loss. I would check more into the sample preparation and the injection for that type of issue.

SelectScience runs 10+ webinars a month across various scientific topics, discover more of our upcoming webinars>>


Rxi-SVOCms Columns

Restek Corp.

Designed specifically for semivolatiles (SVOC) analysis, Restek’s new Rxi-SVOCms columns are designed to provide consistent performance that will keep calibrations passing longer so more samples can be run before needing to recalibrate the instrument or replace the column.

(3)

Links

Tags

Gas ChromatographyGas chromatography (GC) is an analytical technique used to separate and quantitate mixtures of small and volatile compounds. Gas chromatographs or GC systems include components such as GC columns, detectors, pumps and autosamplers. Choose from packed or capillary GC columns, flame ionization (FID), photoionization (PID) electron capture detectors and selective or non-selective detectors. Find the best gas chromatographs in our peer-reviewed product directory: compare products, check customer reviews and receive pricing direct from manufacturers.GC-MS GC-MS (gas chromatography-mass spectrometry) instruments and equipment are used to separate, quantify and identify mixtures of small and volatile compounds, such as polycyclic aromatics, fatty acids and alcohols. Often used in drug detection, forensic investigation and environmental analysis for pesticides and contaminants, GC-MS is a powerful addition to your lab’s analytical capabilities. GC-MS/MS instruments equipped with a qTOF or triple quadrupole analyzers can give greater sensitivity and resolution to your analysis. Find the best GC-MS instruments and equipment in our peer-reviewed product directory: compare products, check customer reviews and receive pricing direct from manufacturers.Water AnalysisAnalytical methods used to test the purity of drinking water include determining the level of contaminants abides to the level set by the Environmental Protection Agency (EPA).Semi Volatile Organic CompoundsSemi volatiles organic compounds (SVOCs) are a groups of compounds that have a low boiling point and evaporate above room temperature. SVOCs include phenols and polynuclear aromatic hydrocarbons (PAH).Gas ChromatographyGas chromatography (GC) is an analytical technique used to separate and analyze gases or volatile liquids in a sample. It is widely used in environmental testing, food safety, pharmaceuticals, and forensic science. GC is ideal for identifying and quantifying compounds that are gaseous or can be vaporized without decomposition. Browse our peer-reviewed product directory to find the best gas chromatography systems, compare products, check reviews, and get pricing directly from manufacturers.