Analysis of Aroclor and Organochlorine Pesticides in Ground Water using Triple Quadrupole GC-MS/MS

14 Jul 2019

USEPA method 608 is GC-ECD method to determine Aroclor and organochlorine pesticides. This method requires the use of second column for confirming the detected compounds due to the low selectivity of the ECD detector comparing with GC-MS/MS. Also pattern recognition is required for accurate identification of Aroclors. Triple quadrupole GC-MS/MS based method offers a solution for the GC-ECD method’s drawbacks by providing high selective analysis. In addition, the type and concentration of Aroclor can be simultaneously determined.

GCMS-TQ8040 NX Triple Quad Gas Chromatograph Mass Spectrometer

Shimadzu Corporation

Featuring Smart Productivity for high-efficiency sample throughput, Smart Operation for quick and easy method development, and Smart Performance for low detection limits and Scan/MRM, the GCMS-TQ8040 NX is a cost-effective, easy-to-use triple quadrupole GCMS for routine analytical work.   With over 32,000 MRM transitions in a single run, the GCMS-TQ8040 NX with Smart MRM can combine over 400 compounds into a single MRM method without sacrificing sensitivity or selectivity, doubling or even tripling laboratory productivity. This results in added throughput before routine maintenance is required and faster return on investment. The Shimadzu GCMS-TQ8040 NX MRM Optimization Tool automatically determines optimum transitions and collision energies for all compounds in a single sequence, and seamlessly incorporates them into the Smart Database Series for fully automated MRM method development. Using flexible MS events, the Smart MRM function routinely determines the best dwell and loop times for >400 compounds in a single method, providing optimum precision and sensitivity. The GCMS-TQ8040 NX can acquire data in the classic MRM mode, or in synchronous Scan/MRM mode for simultaneous qualitative and quantitative results. The Scan/MRM mode simultaneously acquires accurate library-searchable mass spectra and low-level MRM quantitation in a single analysis – a critical function when sample volume is limited. Shimadzu’s proprietary UFsweeper™ technology achieves high-speed MRM analysis up to 800 transitions per second. The Advanced Scanning Speed Protocol (ASSP™) provides high-speed scanning control at 20,000 u/second. ASSP and simultaneous Scan/MRM analysis mode provides high-quality library searchable fragmentation spectra, and accurate low-level quantitative data in a single analysis. This efficient design provides optimum performance in all analysis modes: MRM, SIM, Scan, Scan/MRM, Scan/SIM, Neutral Loss, Product Ion Scan, Precursor Ion Scan and combination modes.

(20)

Links

Tags

Analysis of Aroclor and Organochlorine Pesticides in Ground Water using Triple Quadrupole GC-MS/MS