RNeasy Plus Mini Kit (50)
QIAGENFor fast purification total RNA from cells and tissues using gDNA Eliminator columns or plates
For fast purification total RNA from cells and tissues using gDNA Eliminator columns or plates
This system incorporates features that make it the most technically advanced exponential decay electroporation system currently available. The generator utilizes the BTX Power Platform Technology design and novel digital user interface. The revolutionary Precision Pulse System provides the researcher unparalleled power in controlling the time constant. With the ability to deliver a maximum of 6000 A in the Low Voltage Mode, th…
Chemotaxis assays are ideal for assessing the effects of pharmacological compounds on the motility of tumor cells, and for analyzing the migratory capacity of multiple cell lines in parallel. The format options enable large-scale screening and quantitative comparison of multiple samples in a user friendly, sensitive, HTS system. Quantitative fluorescent method increases sensitivity 10-fold over similar assays on the market…
Immobilon Transfer Membranes are robust, versatile PVDF substrates for a variety of applications, including westerns, dot/slot blots, protein sequencing,and MS analysis. Unlike traditional blotting membranes, Immobilon membranes won’t crack or curl, and they can be cut without fracturing. They are also compatible with a variety of detection chemistries, including radioactive, chromogenic, chemiluminescent, fluorescent, and che…
LED display indicates battery charge status Balanced evenly to prevent fatigue and weighs only 6.7 oz Contoured buttons ensure comfort during pipetting Quick and quiet pump fills a 10-mL pipette in 1.3 seconds Accepts glass or plastic serological pipettes, from 1 to 100 mL Continue pipetting while connected to the charger or adapter These compact pipette controllers feature an ergonomic rounded design for comf…
Shimadzu's Nexera is a genuine all-around HPLC that enables various types of analysis including conventional LC, ultra fast LC and ultra high-pressure LC up to 130 MPa without compromising performance and data quality. The LC-30A Nexera delivers high-speed and high-resolution analysis without sacrificing basic performance parameters such as excellent precision, near-zero carryover, good linearity, stability and ruggedness. O…
The DSX is rapidly becoming the standard in busy clinical and medium-throughput private and industrial labs worldwide because its advanced automation and precise liquid-handling capabilities eliminates variations that occur with manual processes. A cost-effective, open system, the DSX performs the entire complement of analytical steps required for virtually ELISA immunoassays: adding samples and reagents, washing, incubation,…
E4 XLS+ 12-channel pipette, 2-20 µL, uses LTS LiteTouchTM tips
E4 XLS+ 12-channel pipette, 100-1200 µL, uses LTS LiteTouchTM tips
E4 XLS+ 12-channel pipette, 20-300 µL, uses LTS LiteTouchTM tips
Pipet-Lite XLS+ manual 12-channel pipette, 20-200 µL, uses LTS LiteTouch tips.
Rainin Classic manual single-channel pipette, 100-1000 µL, uses universal-fit tips. Finger hook, light springs, silicone shock absorber, accurate, precise, economical (PR-1000)
E4 XLS+ electronic single-channel pipette, 100-1000 µL, uses LTS LiteTouch tips. Simple operation, advanced modes. Password-protection, autoclavable liquid end (E4-1000XLS+)
Bioneer introduces AccuPrep® Nano-Plus Plasmid DNA Extraction Kits - the first in a series of unique and revolutionary nucleic acid purification kits that maximize DNA purity, improve yield and significantly reduce prep time—while minimizing costs. AccuPrep Nano-Plus kits are available in Miniprep, Midiprep and Maxiprep formats. A centrifuge can be used to purify plasmid DNA with our AccuPrep Nano-Plus kits, and, thanks to our…
Bioneer’s core competency in delivering the most rigorously manufactured nucleic acids, includes providing the industry’s highest quality Custom RNA oligos. To cover all of your bases, we manufacture RNA oligos with our patented Bio-RP purification which approaches near HPLC quality. For your most stringent applications, we offer a wide array of modification options and services including bar-code labeling and annealing chimer…
The X-Cite® 120PC Q system uses a 120-watt lamp to deliver rich spectral excitation with a uniformly illuminated field of view, the convenience of pre-aligned lamps, 2000 hour lamp lifetime, and adjustable iris - with the added benefit of being computer controllable. The straightforward RS-232 command set easily allows integration into automated systems as well as commercially available imaging software platforms. The X-Cite®…
The X-Cite® Optical Power Measurement System includes both the X-Cite® XR2100 Power Meter and the X-Cite® XP750 Objective Plane Power Sensor. Designed for measuring optical power in watts at the specimen level, the X-Cite® XP750 has a low, sleek profile that fits on the microscope stage and offers the versatility of measuring power output from an X-Cite® illuminator or any other epi-fluorescence light source.
BIOSTAT® CultiBag RM single-use bioreactor for the cultivation of all cell types, including mammalian cells, plant cells, insect cells, stem cells and microbial cells. Application-driven packages are available for culturing from 100 ml to 300 l. BIOSTAT® CultiBag RM is a single-use bioreactor utilising rocking motion agitation with low shear. The feedback control loops using single use sensors for pH and DO, bring new levels o…
Not treated (or medium binding) polystyrene surface is hydrophobic in nature and binds biomolecules through passive interactions Is suitable primarily for the immobilization of large molecules, such as antibodies, that have large hydrophobic regions that can interact with the surface Untreated microplates have a binding capacity of approximately 100 to 200ng IgG/cm2 Total volume is 330 µL; recommended working volume of up…
Round bottom wells with 330 µL total volume Recommended working volumes of 75 to 200 µL Treated for optimal cell attachment Sterilized by gamma radiation and certified nonpyrogenic Individual alphanumeric codes for well identification Bulk packed 20 per bag
The In-Vivo motorised micromanipulator (IVM) was developed to meet the requirements of the most demanding in-vivo applications. High quality materials and precision assembly, along with the super smooth motion and long travel means that the IVM is stable, versatile and low-noise. It’s perfectly suited to electrophysiology and microinjection procedures and is available with single or three axes of motion. Features: • Ultra stab…
The Scientifica Universal Motorised Stage (UMS) provides rapid, accurate and intuitive remote control translation of your microscope around a sample. Designed to be used in combination with a fixed nose microscopy platform, the 400mm x 200mm UMS provides complete microscope support and the 50mm of travel in both the X and Y axes allows you to roam the largest of samples. An optional Z axis focus control is also available provi…
The LabSmith HVS448 High Voltage Sequencer provides eight high-voltage channels with programmable sequencing for an entirely new level of voltage manipulation. With innovative voltage supply/sensing, current supply, current sensing, and a ground-breaking sequencing environment, the HVS448 integrates your entire experiment, simply and safely. • Eight channels supplying/sensing up to ±3.0kV/±6mA • 1 kHz sequencing for microfluid…
The SIU-102 is an ideal unit for providing cell stimulus in an imaging application. Unfortunately, the SIU-102 is not compatible with electrophysiological applications. This instrument features optical isolation at the input and transformer isolation at the output. Timing pulses can be controlled by any device capable of generating a TTL level positive pulse (for example, a computer with data acquisition). Positive or negati…
The DP-301 is a single channel AC/DC differential pre-amplifier highly suited for EEG, EKG and extracellular recording. High input impedance High common mode rejection Low noise with high gain High tolerance to DC offsets Bandwidth filtering available High Input Z, High CMR High common mode rejection is very important in minimizing electrical interference. The high input resistance of the DP-301 (1012 ohm typical…