Model A307 Sample Oxidizer
RevvityThe Model 307 Oxidizer utilizes the patented "open/close" flame oxidation technology. The result: an oxidizer that will expand your experimental designs in liquid scintillation counting.
Spectroscopy enables researchers to identify chemical compounds, determine molecular structures, and understand fundamental properties of samples through the analysis of absorption, emission, or scattering of light or other forms of radiation. From infrared (IR spectroscopy) to ultraviolet (UV-visible spectroscopy) wavelengths, spectroscopy plays a vital role in various scientific fields. Explore how spectroscopy drives innovation and discovery across diverse research areas.
The Model 307 Oxidizer utilizes the patented "open/close" flame oxidation technology. The result: an oxidizer that will expand your experimental designs in liquid scintillation counting.
Fluorovette™ as a replacement to low volume quartz-silica cells. The incredibly low cost makes them disposable which is great for assays which require maximum sensitivity down to 2nM detection limit and zero carryover between measurements. Avoids trapping air bubbles due to unique composite design UV Transparent down to 220nm Sample volume: 50 uL Pathlength: 0.75 mm Dead Volume in channels: 1 uL for the inlet channe…
The Biologic stopped-flow SFM-400 and Quench-flow QFM-400 are considered to be the benchmarks. rapid kinetics stopped flow analysis From simple SFM-20 2 channel to 5 channels with quench flow Perform double mixing experiments with control over delay time and mixing time Independent stepper motor control of each syringe gives you total control Full software control with optional Biokine software for quality data processi…
For spectral recording in UV/Vis spectroscopic modes. MOS-450/AF for absorbance and fluorescence modes. This includes a dual illumination monochromator and single-channel detection. MOS-450/AF-CD for absorbance, fluorescence, fluorescence anisotropy and circular dichroism modes. This includes the same hardware as the /AF version, with in addition : polarizing optics, photoelastic modulator and synchronous signal detectio…
Advantec Japan, manufactures two great fraction collectors which can be used for both HPLC and other types of fraction collecting. Both units offer exceptional flexibility from the rugged x-y-z operation High quality Construction Wide choice of racks Software compatible Large sample capacity Prep option Collect by time, vol, drop or peak signal detection CHF100SA Routine Collector A low cost Fraction Collecto…
The AccuSpot automates LC microfractionaction, spotting and preparation for MS analysis. With the AccuSpot system, LC eluent can be accurately and continuously spotted onto target plates, in trace amounts of 50nL or more. This allows for automatic preparation of target plated for MALDI-TOF-MS measurements. By using it in conjunction with Shimadzu's 1D or 2D Micro LC System and Shimadzu Biotech's AXIMA MALDI-TOF instruments,…
Minimal Training - Easy to Use The large liquid-crystal display (LCD) has been incorporated with easy to follow prompts, large fonts, and graphics to help reduce the time needed to get your results. The description on the instrument's soft keypad quickly guides you through specific programs. Mighty Performance with Quantitative Methods Everything from simple concentration measurements up to sophisticated quantitative calibrati…
High Sensitivity The SolidSpec 3700/ 3700DUV is designed for the highest sensitivity. It is the first UV-VIS-NIR spectrophotometer with three detectors: a photomultiplier tube (PMT) detector for the ultraviolet and visible region, and furthermore InGaAs and PbS detectors for the near-infrared region. The use of the InGaAs and PbS detectors makes the sensitivity in the near-infrared region extremely high. Up to now, all convent…
MicroScint™-20 cocktail was formulated to accept dilute aqueous samples at up to 20% loading (up to 25 µL in 100µL MicroScint™-20). With these sample types MicroScint™-20 cocktail mixes easily and completely upon agitation with an orbital shaker. It is the cocktail of choice for counting filters that have not been completely dried. MicroScint™-20 cocktail has an absolute, unquenched Tritium efficiency of approximately 52% when…
MicroScint™-E cocktail was developed for assays that require in-situ partitioning of the radionuclide-containing lipid phase from the aqueous phase in microplates. In this respect MicroScint™-E cocktail is suitable for extracting lipids or other non-polar compounds from the aqueous phase in such extraction assays. It enables direct counting of the samples after addition of the cocktail, because the label is preferentially take…
MicroScint™-O cocktail is suitable for counting non-polar organic samples such as hexane, heptane, ethyl acetate etc., and for dried filters. Since MicroScint™-O cocktail does not contain surfactants it is not miscible with water and is therefore unsuitable for aqueous samples. It is particularly useful for organic samples produced from enzyme inhibition assays. MicroScint™-O cocktail has an absolute, unquenched Tritium effici…
MicroScint™-PS cocktail was specifically formulated for polystyrene compatibility. It is suitable for use with virtually any type of microplate and provides long term counting stability. MicroScint™-PS has almost identical sample handling capabilities to MicroScint™-20 cocktail with respect to sample concentration and loading. MicroScint™-PS cocktail provides high counting stability with minimal change in count rate within 24…
Specifically formulated to accept up to 2.0 M ammonium formate at a 1:1 ratio with fast and easy mixing. Ultima-Flo AF will appeal particularly to those researchers using ammonium formate buffers to elute radiolabeled inositol phosphates from HPLC columns. Other samples such as 0.1 M imidazole, pH 7.5, are also easily accepted.
Waters offers PoraPak™ Rxn, a family of polymer-based chromatography products for superior cleanup of synthetic reactions. PoraPak Rxn products are available in two chemistries: PoraPak Rxn CX, a strong cation-exchange sorbent and PoraPak Rxn RP, a reversed-phase sorbent.PoraPak Rxn sorbents are based on copolymers that exhibit the following properties:Hard material that does not develop increasing back pressure with flowLitt…
SDB-XC is a poly(styrenedivinylbenzene) copolymer used as a reversed phase sorbent for solid phase extraction. SDB-XC is not bonded to silica but is a 100% copolymeric particle that is spherical, porous and cross-linked. It does not exhibit the secondary cationic (silanol) interactions and pH limitations common to bonded silica sorbents, so it offers more predictable and reproducible reversed phase interaction.
Cation-SR is a poly(styrenedivinylbenzene) copolymer that has been modified with sulfonic acid. Note that Cation-SR is not bonded to silica but is a 100% copolymeric particle that is spherical, porous and cross-linked. The functional group imparts selectivity for cationic analytes, such as primary, secondary and tertiary amines.
3M Bioanalytical Anion-SR is a poly(styrenedivinylbenzene) copolymer that has been modified with quaternary ammonium groups. Note that the 3M Anion-SR is not bonded to silica but is a 100% copolymeric particle that is spherical, porous and cross-linked. The functional group imparts unique selectivity for anionic analytes, such as Endothall, Dalpon and haloacetic acids.
The Oil & Grease Disk was specifically designed for EPA Method 1664 (N-Hexane Extractable Materials (HEM) and Silica Gel Treated N-Hexane Extractable Material (SGT-HEM) by Extraction and Gravimetry). EPA Method 1664 Revision A was approved for use in the United States and published in the Federal Register on May 14, 1999. The Oil & Grease Disk incorporates C18 sorbent particles within a hydrophobic matrix. For EPA Method 166…
Empore™ Chelating Disks provide a way to selectively remove multivalent metal cations from solutions. This selectivity can be used to concentrate metals from a sample for analysis or to isolate and remove metal interferences from a complex organic or inorganic sample matrix. In the latter case, the purified filtrate is ready for use. The chelating disk has an affinity for multivalent (primarily 2+ and 3+) transition element…
Empore Carbon Disks are designed for the extraction of volatile, highly polar, and water soluble compounds from aqueous solutions. The Empore Carbon Disk provides all the advantages of activated carbon in a compact and thin Empore Disk.
Commonly used for the solid phase extraction of analytes from complex sample matrices. A variety of functional groups, such as octadecyl (C18) and octyl (C8) can be bonded to the silica surface to provide non polar interactions. Each of these sorbents exhibits unique properties of retention and selectivity for a particular analyte. The choice of which sorbent is best for a particular method will be influenced by the percent…
3M bioanalytical's Empore c18 90 Disk-Commonly used for the solid phase extraction of analytes from complex sample matrices. A variety of functional groups, such as octadecyl (C18) and octyl (C8) can be bonded to the silica surface to provide non polar interactions. Each of these sorbents exhibits unique properties of retention and selectivity for a particular analyte. The choice of which sorbent is best for a particular me…