Cecil Aquarius CE 7400S, CE 7400 / 7500 Spectrophotometers
Cecil Instruments LimitedThese spectrophotometers provide superb performance, powerful ESEF software and are fully accessorised.
These spectrophotometers provide superb performance, powerful ESEF software and are fully accessorised.
Thermally Stable Polar Stationary Phase BPX70 is a phase specifically designed to aid in the analysis of FAMEs no matter how simple or complex the mixture.BPX70 utilizes the phase technology developed by SGE to enhance the performance of what would be, "just another cyanopropyl stationary phase".The incorporation of the aromatic silphenylene group into the siloxane backbone provides many benefits. As the initials BP (Bonded Ph…
The Classic Series gel tanks come with turn and cast gel trays or gasketed gel trays, making gel pouring as simple as possible. Designed to give you total felxibility in your application. Avaialble in a variety of sizes: From the small 7 x 8cm gel size right up to the 20 x 40cm gel size for high-throughput applications. Product Detail: Turn and Cast Submarine Gel System Three convenient gel sizes: 7x8cm; 9x11cm & 12x14c…
Eppendorf offers a line of advanced autoclavable stirrer vessels suitable for temperature control with the compact DASGIP Bioblock.
The INGENYphorU system is built around the patented U-shaped spacer. With this spacer design gel casting can be done with the gel sandwich and the comb in the electrophoresis cassette. The cassette holds two 28 x 18 cm gels. Combs are available in 20-well, 32-well and 48-well.A buffer system as well as other accessories are available.INGENYphorU Benefits: Buffer flow in top compartment adjustable from outside Loading vol…
Powered by Adaptive Focused Acoustics ® (AFA ® ) Technology
The IVIS ® Lumina Series III brings together years of leading optical imaging technologies into one easy to use and exquisitely sensitive bench-top system.
100–120/220–240 V, power supply for high-current applications such as western blotting, includes power cord
Applied Biosystems® ArcturusXT™ Microdissection System Flexible & Modular Laser Capture Microdissection (LCM). This Laser Capture Microdissection (LCM) method is extraordinarily gentle and ideal for microdissection of single cells or small numbers of cells. The ArcturusXT™ and Veritas™ microdissection instruments each combine LCM and UV laser cutting for ultimate microdissection flexibility. These instruments remove the guessw…
The Model 2400 is a low-noise, full-featured intracellular/extracellular amplifier designed for voltage clamping using patch electrodes on single channels or whole cells. Its unique design allows fast intracellular current clamp measurements with sharp electrodes. Advanced circuit design techniques using field programmable gate arrays eliminated noisy microprocessors. Full-Function Patch Clamp Amplifier for both whole cell…
In combination with the included Enhancer Solution, the reagent efficiently delivers functionally active proteins, antibodies and peptides into the cytoplasm of cells. Proteins of different sizes and net charge (different pI) can be delivered into various cell types, including primary, adherent and suspension cells (see Fig. 1, 2 and list of cells below). The reagent can be used in the presence or absence of serum. TurboFect P…
Complete, automated specimen processing system for front-end pre-analytics in microbiology
The EPC 10 Double and EPC 10 Triple patch clamp amplifiers are the optimal instruments for performing double or triple patch experiments. Although either two (EPC 10 Double) or three (EPC 10 Triple) amplifiers are combined in a single housing; each amplifier is completely independent with clearly defined operation and handling. HEKA’s software stimulates the desired amplifier and selected channels are programmed without tediou…
The Yeastmaker Yeast Transformation System 2 provides a high-efficiency polyethylene glycol (PEG)/LiAc-based method for preparing and transforming competent yeast cells. The Yeast Transformation System 2 protocol provides a higher and more reliable transformation efficiency than many other commonly used methods as a result of specially formulated "YPD Plus" recovery medium, which results in more surviving transformed colonies…
Capable of fast data measurement with sensitivity five times higher than previous models, the GCMS-QP2010 Ultra offers improved applicability for comprehensive two-dimensional GC and ultra-high separation. Shimadzu used new, patented mass spectrometry technology called Advanced Scanning Speed Protocol (ASSP™), a firmware protocol that optimizes the ion transmission hardware parameters with a highly efficient data collection al…
The Sciclone™ G3 NGSx workstation is a complete benchtop solution for the automated construction of up to or greater than 96 libraries per day. For Research Use Only. Not for use in diagnostic procedures.
The Chromaster Analytical HPLC System from Hitachi has established new limits in Performance, Ease-of-Use, and Robustness. Innovative low-pressure gradient mode, “High Frequent Mode,” and Hitachi’s proprietary real-time feedback control system greatly suppress liquid pulsation resulting in unparalleled retention time and gradient reproducibility. The Hitachi Chromaster is also available with 60 MPa maximum pressure.
Reliability, speed, traceability. Characterised by its ease-of-use, speed and image quality, the InnoScan 710 from Innopsys is an ideal tool for routine microarray reading. Supplied with a validation slide and associated Mapix software, full compatibility with traceability standards is assured.InnoScan 710 has a special feature of using a real-time autofocus system that offers the advantage of making it insensitive to substra…
The classically designed, yet never duplicated laboratory fermentor: Universally designed for a wide-range of applications with low operating costs Medium volumes can be produced even if there is no steam available in your lab Consistent design philosophy, the concept has never been modified since its existence although others have certainly tried to replicate it Available in a steel head-glass cylinder or steel head…
The new ViiA™ 7 System is a 7th generation real-time PCR system that enables high-productivity qPCR through flexibility, performance, integrated TaqMan® Assay content, and the most advanced features available. Welcome to a new era in high-productivity qPCR - Easy touch-screen interface - Rapid block change - Intuitive software with ReadiApp™ Feature and QuickStart - Integrated TaqMan® Array block - OptiFlex™ System
For optimal imaging and microanalysis in electron microscopy, it is imperative to have a clean, well-prepared specimen. This is especially true for many modern electron microscopes, which employ high brightness electron sources, such as LaB6 filaments and field emission(FE) guns. Such high brightness systems combine a small electron probe for microanalysis with increased beam current density, giving high resolution specimen im…
100–240 V, multiplex array system, includes reader, microplate platform, Bio-Plex Manager 5.0 software, PC, calibration kit, validation kit 4.0, MCV plate IV, reservoir, sheath fluid, 2 sample needles
The Bio-Plex Pro Human Cytokine Screening Panel enables you to interrogate 17 cytokine and chemokine cell signaling molecules in complex extracellular events and signaling pathways involved in heart disease, Alzheimer's disease, autoimmunity and allergy, infectious diseases, inflammation, cancer, and neurodegeneration. This high-performance, broad screening panel consists of a biologically-relevant collection of adaptive immun…
Software, PC or Mac, for automated image capture, optimization, and 1-D data analysis, for use with Gel Doc™ EZ, Gel Doc XR+, ChemiDoc™ XRS+, ChemiDoc MP, and GS-900™ imaging systems