PTFE coated silicone mat, for use with 384 square well plates 1.1-MTP-96
Chromacol LtdPTFE coated silicone mat, for use with 384 square well plates. Compatible with Greiner, Whatman, Polyfiltronics and Abgene
Identification and optimization of the chemical, series of chemicals or bio-molecule that will interact with the target using impartial, expert opinion about the best equipment, services and the latest techniques
PTFE coated silicone mat, for use with 384 square well plates. Compatible with Greiner, Whatman, Polyfiltronics and Abgene
PTFE coated silicone mat, for use with large volume glass vials (1.1-MTV-96)
96 well micro titer rack with large volume glass vialspre-inserted. With 5 sealing mats
Multi lingual GeneQuest, spectrophotometer for fast, reliable and easy DNA and RNA measurements.
Multi lingual, 4 nm bandwith, single beam spectrophotometer, for reliable and easy measurements.
This four channel degasser is very efficient at degassing mobile phase, as and when required.
Feature uniform skirt heights for greater robotic gripping surface Solvent resistant polypropylene provides compatibility with many common organic solvents (e.g., DMSO, ethanol, methanol) Sterile and certified DNase- and RNase-free Total volume is 500 µL
High binding surface binds medium (>10kD) and large biomolecules that possess ionic groups and/or hydrophobic regions Binding capacity is approximately 400 to 500ng IgG/cm2 Ideal for immunoassays Without lids, lids supplied separately Bottoms are 60% thinner than conventional polystyrene plates, resulting in lower background fluorescent and enabling readings down to 340nm Designed to reduce well-to-well crosstalk during…
Not treated (or medium binding) polystyrene surface is hydrophobic in nature and binds biomolecules through passive interactions Is suitable primarily for the immobilization of large molecules, such as antibodies, that have large hydrophobic regions that can interact with the surface Untreated microplates have a binding capacity of approximately 100 to 200ng IgG/cm2 Without lids, lids supplied separately Total volume is…
Note: License Description - PLT,96WL,STRIPWELL,1X8,HIGH BI May be used in a variety of laboratory assays Flat bottom strips are designed to easily break apart and are pre-assembled in an style strip holder that allows each individual well to be positioned back into the plate once broken High binding surface binds medium (>10kD) and large biomolecules that possess ionic groups and/or hydrophobic regions. Binding capacity is…
Not treated (or medium binding) polystyrene surface is hydrophobic in nature and binds biomolecules through passive interactions Is suitable primarily for the immobilization of large molecules, such as antibodies, that have large hydrophobic regions that can interact with the surface Binding capacity of approximately 250 ng of mouse IgG/cm2 EIA/RIA plates are tested on lot-to-lot basis and the certification results for ea…
Not treated (or medium binding) polystyrene surface is hydrophobic in nature and binds biomolecules through passive interactions Is suitable primarily for the immobilization of large molecules, such as antibodies, that have large hydrophobic regions that can interact with the surface Untreated microplates have a binding capacity of approximately 100 to 200ng IgG/cm2 Recommended working volume of up to 75 to 200 µL Confor…
Flat bottoms Nonreversible lids with condensation rings to reduce contamination Individual alphanumerical codes for well identification Uniform footprint for ease in stacking Treated for optimal cell attachment Sterilized by gamma irradiation Certified nonpyrogenic
Flat bottoms with 360 µL total volume Recommended working volumes of 75 to 200 µL Treated for optimal cell attachment Nonreversable lids with condensation rings to reduce contamination Sterilized by gamma radiation and certified nonpyrogenic Individual alphanumeric codes for well identification Bulk packed 20 per bag
These Costar® Spin-X® centrifuge tube filters have a 0.45 µm pore CA membrane-containing filter unit within a 500 µL capacity polypropylene microcentrifuge tube. Cellulose acetate (CA) membranes provide fast flow rates and low protein binding Ideal for removing bacteria, particles, or cells from liquids, HPLC sample preparation and DNA removal from agarose or acrylamide gels. Sterile and certified nonpyrogenic and DNase-/RN…
These Corning® syringe filters have acrylic copolymer housings, female Luer lock inlets and male Luer slip outlets. Polyethersulfone (PES) membranes provide the fastest flow rates, low protein binding and low extractables 100% integrity tested, sterile and certified nonpyrogenic and noncytotoxic Manufactured in accordance with ISO 9001 standards
Not treated (or medium binding) polystyrene surface is hydrophobic in nature and binds biomolecules through passive interactions Is suitable primarily for the immobilization of large molecules, such as antibodies, that have large hydrophobic regions that can interact with the surface Untreated microplates have a binding capacity of approximately 100 to 200ng IgG/cm² Without lids, lids supplied separately Total volume is…
Not treated (or medium binding) polystyrene surface is hydrophobic in nature and binds biomolecules through passive interactions Is suitable primarily for the immobilization of large molecules, such as antibodies, that have large hydrophobic regions that can interact with the surface Total volume is 190 µL; recommended working volume of up to 25 to 125 µL Conforms to standard microplate footprint and dimensions Without l…
This microplate has half the growth area of a standard 96 well plate Flat bottoms with 190 µL total volume White walled plates enhance luminescent signals and have low background luminescence and fluorescence Opaque walls to prevent well-to-well crosstalk Nonreversable lids with condensation rings to reduce contamination Sterilized by gamma radiation and certified nonpyrogenic Bulk packed 20 per bag
The Direct Connection UNIGUARD allows the guard cartridge outlet to be directly placed against the analytical column inlet frit. Product detail: We recommend all analytical columns are protected by a guard cartridge, which is replaced on a regular basis. The ID of the analytical column determines the correct ID for the guard cartridge. We offer 10x1, 10x2, 10x3, 10x4mm guard cartridges in all our stationary phases to ensur…
The Javelin guard design is a one-piece format that can be installed without wrenches and requires no holder, which allows quick and easy replacement. Product detail: We recommend all analytical columns are protected by a guard column or cartridge, which is replaced on a regular basis. The ID of the analytical column determines the correct ID for the guard, so we offer 1.0, 2.1, 3.0 and 4.0 diameter Javelin guard columns in…