3Mâ„¢ Emporeâ„¢ UR-SD 3ml Cartridge
3M BioanalyticalThis chemistry promotes high retention of a wide range of analytes, reducing method development time and facilitating a generic approach to sample preparation.
Trusted information for laboratory scientists on Anti-Doping Science lab products and techniques on SelectScience, including Hematology, Biochemistry, HPLC and UHPLC, GC / MS.
This chemistry promotes high retention of a wide range of analytes, reducing method development time and facilitating a generic approach to sample preparation.
Functional groups, such as octyl (C8) and octadecyl (C18), can be bonded to the silica surface to provide non polar interactions. Each of these sorbents exhibits unique properties of retention and selectivity for a particular analyte. The choice of which sorbent is best for a particular method will be influenced by the percent recovery of analyte from the sample matrix and the cleanliness of the resulting chromatography.
SDB-XC is a poly(styrenedivinylbenzene) copolymer used as a reversed phase sorbent for solid phase extraction. SDB-XC is not bonded to silica but is a 100% copolymeric particle that is spherical, porous and cross-linked. It does not exhibit the secondary cationic (silanol) interactions and pH limitations common to bonded silica sorbents, so it offers more predictable and reproducible reversed phase interaction.
The Empore™ High Performance Extraction Disk Plate differs in design from plates offered by other manufacturers and requires a specific vacuum manifold. Manifolds supplied by different plate manufacturers are specific to the design of their plates and cannot generally be used with plates from other manufacturers. In some cases, the use of spacers to raise/lower the height of a collection device inside the manifold may overco…
Replacement gaskets are available with the vacuum manifold assembly. The gasket can become worn over time and the seal between the plate and the manifold will be affected. This may result in poor vacuum pressure and negatively effect flow rates. The gasket should be checked regularly and replaced when it becomes worn.
Empore Filter Aid 400 has been shown to improve flow rates and recoveries for separation and filtration of water samples containing suspended solids. When placed on top of the Empore™ Extraction Disk at a depth of about 1 cm, Empore™ Filter Aid 400 acts as depth filter to inhibit the migration of suspended solids to the surface of the disk. This reduces extraction time and improves rates and recovery of analytes.
Spark has introduced the second edition of HySphereâ„¢ C8 End-Capped cartridges. We have selected a new perfect Spherical sorbent material with a narrow particle size distribution. This will create less back pressure during operation and allows you to run higher flow rates compared to our current HySphereâ„¢ C8 (EC). The new cartridge has the same excellent characteristics such as high extraction capacity and selectivity
Sample Type:Serum; Sample Size:25 µl; Size:100 Tests; Range:3 - 150 ACE units; Sensitivity:<5 ACE Units; Incubation Time:15 minutes
Sample Type:Serum; Sample Size:25 µl; Size:1200 Tests; Range:3 - 150 ACE units; Sensitivity:<5 ACE Units; Incubation Time:15 minutes