MB3600 FT-NIR Laboratory Analyzer for QA/QC
High-performance FT-NIR Analyzer designed for QA/QC
The MB3600 is the most versatile high performance FT-NIR analyzer in the market specifically designed for QA/QC. The double-pivot interferometer’s innovative design ensures increased robustness. The optics are permanently aligned, enabling more repeatable, reproducible spectroscopy and eliminating the need for dynamic alignment. The scanning mechanism has a lifetime guarantee. With its vertical, space-efficient design, the MB3600 optimizes laboratory workspace and facilitates access to internal components.
First maintenance-free FT-NIR analyzer
The MB3600 FT-NIR laboratory analyzer is a highly effective spectrometer for development and implementation of precise quantitative analysis procedures for:
- Process monitoring method development
- Final product QA
- At line process monitoring
The MB3600 analyzer can be used to perform analysis of liquids, powders/pellets and gels.
No consumables.
The MB3600 contains fixed components that do not wear out with use, meaning no components to replace or adjust. With the MB3600, the HeNe LASER is replaced by a solid state laser. All optics are non-hygroscopic. Purging is not required for protection of optics.
Long-life source.
To maximize reliability, the source is operated so as to provide a 10-year expected lifetime.
Versatility at a glance
The arid-zone open sample compartment of the MB3600 addresses all the needs of the modern analytical laboratory. It can hold a wide variety of easily swappable ABB or third-party accessories that do not require alignment. The instrument can also be purged if needed.
Brochures
MB3600 - Reliable FT-NIR Laboratory Analyzer Designed for QA/QC
The MB3600 is the result of many years of experience in the space, academic, chemical, pharmaceutical and petrochemical industries. Designed with the concerns of lab users in mind, the MB3600 is the ultimate in ease of use, reliability and consistency.
Quantitative analysis of acid value, OH value and viscosity in acrylic acid esters using FT-NIR spectroscopy
Wet-chemical conventional laboratory reference methods for acrylic acid esters are tedious, time-consuming, and expensive.
In this application note, explore how FT-NIR spectroscopy can be used successfully to determine OHv, Av, and Visco in acrylic acid esters. This methodology requires no sample preparation thus providing a quicker, cheaper, and simpler alternative for QA/QC product lots certification and release.
Fast and efficient solution for crude oil measurement for refiners using NIR technology to optimize the CDU process rapidly and proactively
This application note from ABB Analytical Measurements discusses and demonstrates how ABB near-infrared spectroscopy (FT-NIR) is designed to provide a fast and efficient online crude oil characterization solution, enabling planners to optimize their processes based on accurate real-time knowledge of a given crude oil input.
Quantification of organic peroxide in different substrates by NIR spectroscopy
In this application note, ABB Analytical Measurements demonstrates that NIR spectroscopy is nondestructive, easy to operate without sample preparation, and a fast technique to measure organic peroxides. In the study, two organic peroxides (dicumylperoxide and 2,5-bis(tert-butylperoxy)-2,5-dimethyl-hexane) were measured for three final products.
Powder blending monitoring and composition quantification using FT-NIR spectroscopy
Blending powders to obtain a homogeneous product is a common procedure in the chemical and pharmaceutical industries. In this application note, ABB Analytical Measurements demonstrates how FT-NIR spectroscopy can be used to monitor blending processes and to establish when blends become homogeneous.
Quantitative Analysis of Acid Value, OH Value and Viscosity in Acrylic Acid Esters using FT-NIR Spectroscopy
Acrylic acid esters are formed by the reaction of acrylic acid with alcohols. Hydroxyl value (OHv), acid value (Av) and viscosity (Visco) are commonly used to characterize and certify final acrylic acid ester products. OHv and Av provide an indication on synthesis completion, while Visco allows estimation of the molar mass of the produced monomers. In this application note, ABB Analytical Measurements performs the quantitative analysis of acrylic acid esters by FT-NIR spectroscopy by evaluating the OHv, Av and Visco.
Determination of ACH, Free HCN, DEA, Water, Acidity, SO₂ and Acetone in ACH Process
Acetone cyanohydrin (ACH) is an organic compound used in the production of methyl methacrylate, the monomer of the transparent plastic polymethyl methacrylate (PMMA), also known as acrylic. ACH process consists of three different stages called reactor, crude, and pure product. In this application note, ABB Analytical Measurements assesses the feasibility of determination following chemical properties in the three different process stages by FT-NIR to provide real-time feedback and optimize the process. Those properties are ACH, free HCN, and diethyl amine (DEA) in reactor, water and SO₂ in crude, and acetone, acidity, water and phenothiazine (PTZ) in pure product.
Quantitative Analysis of Citric Acid
Citric acid is an important organic acid used extensively in food and pharmaceutical industries. It is produced mainly by submerged fermentation and the progress of the reaction can be followed by pH titration. However, wet-chemical conventional laboratory reference methods for titration are tedious and time consuming. In this application note, ABB Analytical Measurements demonstrates the use of FT-NIR spectroscopy as a quicker, cheaper and simpler alternative for reaction monitoring.
Qualification of Powdered Gelatin Agar by NIR Spectroscopy
Agar is a mixture of polysaccharides widely used in food, chemical and pharmaceutical industries for its jelly-like structure. As it is obtained from different species of red algae, its quality can vary from lot to lot. In this application note, ABB Analytical Measurements determines if NIR spectroscopy can be used to identify optimal and sub-optimal lots of powdered gelatin agar.
Celebrating 50 years of customer-inspired innovation
ABB Measurement and Analytics’ Quebec factory marks half a century of advanced analytical solutions













