Products & ReviewSeparations

Atlantic® Solid Phase Extraction Disks

BiotageWorldwide

SPE Disks for Water Extraction

Request Pricing
Biotage

Receive your quote directly from the manufacturer.

Ease of Use
After Sales Service
Value for Money
Be the first to leave a review
Description

Atlantic® ReadyDisks are solid phase extraction (SPE) disks constructed to maximize surface area interactions with the analytes in solution. The disks are designed for use with both manual and automated solid phase extraction systems. Atlantic® Ready Disks accommodate high sample flow rates for rapid processing of large sample volumes.

Highlighted Applications:

  • SVOCs
  • Pesticide, Herbicide & Insecticide
  • PCBs, PAHs & EPH
Application NoteSeparations

Investigating the extraction efficiency of dioxins in several types of aqueous matrices by automated solid phase extraction utilizing disks

In this application note, Biotage outlines an automated extraction method utilizing the Atlantic® DVB SPE Disk and the Biotage automated and manual SPE solutions for the extraction of dioxins and furans in several water matrices. The first section highlights the use of the Biotage® Horizon 5000 fully automated extraction system and the method used for this application. Additionally, there is an Application Modification section that highlights the use of the Biotage® Horizon 4790 (with data and discussion) and Biotage® VacMasterTM Disk for this application.


Application NoteSeparations

Determining polycyclic aromatic hydrocarbons (PAHs) in sea water using automated solid phase extraction

In this application note, Biotage outlines optimized methods for the extraction of polycyclic aromatic hydrocarbons from sea water using the Atlantic® HLB solid phase extraction disk processed using Biotage automated or manual SPE solutions and DryVap® Concentrator System. The first section highlights the use of the Biotage® Horizon 5000 fully automated extraction system and the method used for this application. Additionally, there is an Application Modification section that highlights the use of the Biotage® Horizon 4790 and Biotage® VacMaster™ Disk for this application.


Application NoteSeparations

Analysis of pharmaceuticals in water by automated solid phase extraction

In this application note, Biotage outlines an automated extraction method utilizing the Atlantic® HLB-M SPE Disk and Biotage automated and manual SPE solutions for the extraction of pharmaceuticals in water. The first section highlights the use of the Biotage® Horizon 5000 fully automated extraction system and the method used for this application. Additionally, there is an Application Modification section that highlights the use of the Biotage® Horizon 4790 (with data and discussion) and Biotage® VacMaster™ Disk for this application.


Application NoteSeparations

Determination of endocrine disrupting hormones in drinking and wastewater utilizing the Atlantic HLB SPE Disk

In this application note, Biotage outlines an automated extraction method utilizing the Atlantic® HLB SPE Disk and the Biotage automated and manual SPE solutions for the extraction of hormones in drinking water. The first section highlights the use of the Biotage® Horizon 5000 fully automated extraction system and the method used for this application. Additionally, there is an Application Modification section that will highlight the use of the Biotage® Horizon 4790 (with data and discussion) and Biotage® VacMaster™ Disk for this application.



Application NoteSeparations

Drinking Water Extraction using High-Capacity SPE Disks

For more than 25 years now, the US has been testing for organic compounds in drinking water using US EPA Method 525. The most common version of this method, Method 525, is a diverse method with more than 100 compounds listed in a wide range of chemical groups such as pesticides, polychlorinated biphenyls, and polyaromatic hydrocarbons. Method 525 offers other changes to the method that may also be of use in making the method more rugged. Additional compounds are evaluated and may be added to the method as the regulatory list is amended every few years.




Application NoteSeparations

Triphenyl Phosphate Measurement in Drinking Water using Automated Solid Phase Extraction

Triphenyl phosphate is used as a plasticizer and flame retardant. It is found in foam and televisions as a flame retardant, in candy wrappers, nail polish and other consumer products. It has come into more common use as a safe alternative to polydibrominated ether (PDBE) compounds which were good flame retardants, but found to be a health hazard and have been phased out in many materials. Triphenyl phosphate has become a chemical of concern in several countries. In the US there are airborne exposure limits developed by OSHA. Although triphenyl phosphate is not on the California prop list, which would require listing in public places, there is concern that human exposure may be significant. Recent studies have also indicated concern about possible endocrine disruptor capability. A recent study found that triphenyl phosphate can be absorbed into the body from nail polish. The study found that levels of a metabolite, diphenyl phosphate were elevated seven fold in urine several hours after the nail polish was applied.


Application NoteEnvironmental

Validation of Horizon Technology Disk Extraction Technology for US EPA Wastewater Method 625.1

This application note presents the data collected as part of the demonstration of disk solid phase extraction validation for US EPA method 625.1. Nine different wastewater matrices were evaluated and tested against the criteria listed in Table 6 of method 625.1. The analytes chosen for evaluation were from Tables 1 and 2 in method 625.1, with a few extra analytes from Table 3. The analytes from Table 3 are omitted in this note because there was no acceptance criteria for comparison.

What is Solid Phase Extraction (SPE)?

Solid phase extraction (SPE) is a method of sample preparation that separates and concentrates analytes from solution prior to analysis. In this video find out more about how SPE works, comparing SPE to liquid liquid extraction (LLE).


Automated Sample Preparation Solutions

This video demonstrates the 4790 extractor and how dirty samples are handled for automated sample preparation in analytical testing labs. It highlights the use of discs to remove particulates by combining 47mm, 1 micron and 90mm, 5 micron discs in a novel holder.

Product Overview

Links

Buy Atlantic® Solid Phase Extraction Disks Read Reviews