Products & ReviewSeparations

Thermo Scientific™ Q Exactive™ GC Orbitrap™ GC-MS/MS System

Thermo Fisher ScientificIQLAAAGABPFAQEMZZZAvailable: Worldwide

The Thermo Scientific™ Q Exactive™ GC system is the first-ever combination of high resolution gas chromatography with high-resolution/accurate-mass (HR/AM) Orbitrap detection for the most comprehensive sample characterization. This easy-to-use system provides the most comprehensive characterization of samples in a single analysis for the highest confidence in compound discovery, identification, and quantitation. Building upon…

Thermo Fisher Scientific

The supplier does not provide quotations for this product through SelectScience. You can search for similar products in our  Product Directory.

Reviews

Average Rating 4.6

|9Scientists have reviewed this product

Ease of Use
After Sales Service
Value for Money
Write your own review

Would recommend to everyone!

 

Average Rating 5.0

Application Area:

Analyze tissue samples

This instrument is extremely effective, precise and offers rare versatility. This type of instrument fits perfectly into a scientific environment that requires justification of results via several different methods.

Review Date: 12 Dec 2023 | Thermo Fisher Scientific

Pleasure to use

 

Average Rating 4.7

Application Area:

Toxins and contaminants

The instrument is easy to use and meets my expectation

Review Date: 1 Nov 2022 | Thermo Fisher Scientific

Great instrument.

 

Average Rating 4.7

Application Area:

Analysis of breath metabolites

Product is effective for the analysis of the application - breath metabolistes.

Review Date: 21 Jan 2022 | Thermo Fisher Scientific

Great results, can’t live without this instrument

 

Average Rating 3.7

Application Area:

Trace analysis of Nitrosamines

Perfect device for high resolution mass spec.

Review Date: 24 Dec 2021 | Thermo Fisher Scientific

Great.

 

Average Rating 4.3

Application Area:

Mass spectrometry imaging

High resolution and reproducible. High sensitivity, fast, accurate and easy to handle.

Review Date: 16 Jun 2020 | Thermo Fisher Scientific

Great precision.

 

Average Rating 4.3

Application Area:

Mass spectrometry

Great precision.

Review Date: 12 Mar 2020 | Thermo Fisher Scientific

Can't live without this instrument.

 

Average Rating 5.0

Application Area:

Bioanalysis

Very robust instrument, easy to conduct maintenance. Provide selective data.

Review Date: 9 Mar 2020 | Thermo Fisher Scientific

Nice product

 

Average Rating 5.0

Application Area:

Peptide analysis

Easy to use, very good result, would recommend it to others

Review Date: 8 Feb 2017 | Thermo Fisher Scientific

I would recommend the QExactive to anyone interested in proteomics analyses.

 

Average Rating 4.7

Application Area:

Analyze peptides in biological fluids

The QExactive mass spectrometer is great. It is very easy to set up methods and produces reproducible results.

Review Date: 19 May 2016 | Thermo Fisher Scientific

The Thermo Scientific™ Q Exactive™ GC system is the first-ever combination of high resolution gas chromatography with high-resolution/accurate-mass (HR/AM) Orbitrap detection for the most comprehensive sample characterization.

This easy-to-use system provides the most comprehensive characterization of samples in a single analysis for the highest confidence in compound discovery, identification, and quantitation. Building upon the flexible modularity of the Thermo Scientific™ TRACE™ 1300 Series GC, including user-exchangeable injectors and detectors, the Q Exactive GC system has the quantitative power of a GC triple quadrupole MS combined with the high precision, full scan high-resolution/accurate-mass capability that only Orbitrap technology can offer.

Key Features:

  • Advanced quadrupole technology (AQT) for high transmission of selected masses
  • Resolving power up to 120,000 at m/z 200
  • Part-per-trillion-level sensitivity
  • Thermo Scientific™ Extractabrite™ ion source for robust, rugged electron impact (EI) and chemical ionization (CI) performance
  • Curved linear C-trap for precise ion injection
  • HCD collision cell for higher energy collisional dissociation provides MS/MS ion characterization
  • Intelligent identification software elucidates the nature of each injected sample.

Applications:

  • Untargeted and targeted metabolomics
  • Food and beverage
  • Industrial analyses
  • Environmental
  • Pharmaceutical
  • Clinical and toxicology

Brochures


Scientific PosterSeparations

The 100 Isotopologue Challenge: Orbitrap Mass Spectrometry as a Means of High‐Dimension Clumped and Position‐Specific Isotope Analysis

The distribution of rare isotopes at molecular scales offers many potential tools in environmental chemistry, geochemistry, biochemistry, and other disciplines. This scientific poster presents the results of an experiment to develop the Thermo Scientific™ Q Exactive™ GC Orbitrap™ instrument as a generalized tool for precise, accurate, rapid and sensitive measurements of molecular isotopic structures.



Application NoteLife Sciences

Chemical Profiling and Differential Analysis of Whiskies using Orbitrap GC-MS

This application note details the use of the Thermo Scientific™ Q Exactive™ GC Hybrid Quadrupole-Orbitrap™ Mass Spectrometer for the chemical profiling of whiskies for the purposes of quality control and authentication. Whisky is a premium spirit beverage that has become an economically important commodity in many regions of the world. As a result, counterfeiting and/or adulteration is commonplace and is a threat to the integrity of the industry. Therefore, it is essential that whisky producers use the available analytical technology to accurately and comprehensively characterize their products. The results demonstrate that the Q Exactive™ is an extremely effective tool for the chemical profiling of complex samples, delivering excellent mass accuracy for all components in a sample that leads to fast and confident characterization of samples regardless of the concentration of the component.


Application NoteSeparations

The Power of High Resolution Accurate Mass Using Orbitrap Based GC-MS

Obtaining mass spectrometer (MS) measurements with high mass accuracy is essential to providing the required selectivity in complex matrices and to increasing the confidence in compound identification and confirmation. For the former, obtaining a consistently high mass accuracy allows the use of very narrow mass extraction windows, taking full advantage of the instrument’s mass resolving power. For the latter, measuring the mass of a chemical with sufficient accuracy allows the chemist to predict the elemental composition and isotopic ratios to help identify the chemical structure of the substance. This application note demonstrates that, using the high resolution of the Q Exactive GC mass spectrometer, excellent mass accuracy is always available to the user, across a wide concentration range and in the presence of a complex chemical background.


Application NoteSeparations

Discovery of emerging disinfection by-products in water using gas chromatography coupled with Orbitrap-based mass spectrometry

The disinfection of drinking water is required in order to protect consumers from potential waterborne infectious and parasitic pathogens. Water is commonly treated by adding chemical disinfectants, such as free chlorine, chloramines, chlorine dioxide, and ozone. However, although very effective in removing disease-causing microorganisms, these disinfectants can react with naturally occurring materials in the water and can form disinfection by-products (DBPs) which can be harmful to human health. Explore the use of a novel gas chromatography (GC), coupled with high-resolution accurate mass Orbitrap™ mass spectrometer (the Thermo Scientific™ Q Exactive™ GC hybrid quadrupole Orbitrap mass spectrometer) for iodo-DBPs detection and accurate mass identification in chlorinated and chloraminated water samples.


Application NoteSpectroscopy

Compliance and Workflows: European Water Framework Directive

Many chemicals produced by human industrial activities have a negative impact on the aquatic environment, even at extremely low concentrations. To measure such an effect, many environmental chemists aim to develop analytical methodologies that can identify a substance at the intended Environmental Quality Standard (EQS) level in complex environmental matrices, including biota. For this reason, the directive 2013/39/EU introduced in August 2013 provides a strategy to monitor pollution of water and biota for European Union member states. This strategy involves the identification of priority substances that pose a significant risk to the aquatic environment. This guide provides an overview of the different compounds to be monitored as well as potential analysis methods.


Application NoteSeparations

The European Water Framework Directive: Environmental Solutions Reference Guide

The European Water Framework Directive is a directive that commits all member states to actively control for a long list of environmental contaminants in all water bodes of the various member states. It lays down a strategy against water pollution, to be applied in all European Union member states, that involves identifying priority substances and monitoring different classes of contaminants; and it includes the first watch list. This guide explains the most appropriate analytical techniques for each class of contaminant to allow efficient and accurate analysis.


Application NoteSeparations

Beer Analysis Applications Notebook: Solutions for the Complete Brewing Process

Beer is the most widely consumed alcoholic beverage in the world and the third most popular drink after water and tea. Beer is typically brewed from four basic ingredients: water, a starch source (e.g., malted barley) brewer’s yeast, and a flavoring agent such as hops. Many varieties of beer result from differences in these ingredients, the additives used, and the brewing process. Once a manufacturer has developed a popular product they need to ensure that they can reproduce it consistently, and in sufficient quantity, in compliance with any local & national regulations. It also needs to remain stable over the shelf-life of the beer. This application notebook presents a range of methods for reducing analysis time without compromising resolution, monitoring processes to determine flavor and stability and characterizing beer using metabolomics approaches.


Application NoteSeparations

High Mass Resolution is Essential for Confident Compound Detection

Analytical laboratories are under ever-increasing pressure to deliver fast results, while maintaining the highest levels of accuracy and confidence. The majority of these laboratories rely on targeted analytical approaches, using both gas chromatography and liquid chromatography coupled to triple quadrupole mass spectrometry (MS) instrumentation. These techniques cover the wide range of chemical classes to be monitored at the required levels of sensitivity and selectivity. However, they are limited to those compounds in the target list and they require careful optimization of acquisition parameters for each compound. This application note explains how high resolution, full scan mass spectrometry provides a solution to the demand for detection and quantification of a growing number of compounds and the retrospective analysis of samples long after data acquisition.



Redefining Routine GC-MS

In this presentation, Paul Silcock, Senior Marketing Manager at Thermo Fisher Scientific, introduces the new Exactive GC Orbitrap GC-MS System. Learn how its highly selective non-targeted data acquisition can quickly analyze samples in food & beverage, pesticides and other routine testing environments.


A Paradigm Shift in GC-MS Routine Analysis

Paul Silcock, Senior Marketing Manager at Thermo Fisher Scientific, explains how GC-MS orbitrap technology can revolutionize analyses in routine laboratories, including labs involved in metabolomics or food safety.
















Product Overview

Links