EZ-2 Series
Using the most advanced proven technology in evaporation science, the third generation of the EZ-2 Series has been designed specifically for solvent removal in life science research; be that concentration of samples or complete drying. The innovative design of the EZ-2 Series presents many advantages for working in parallel within synthesis chemistry, analytical sample preparation and for general-purpose solvent removal n…

The supplier does not provide quotations for this product through SelectScience. You can search for similar products in our Product Directory.
Truly a life-saver! This saves us so much time and improves efficiency in the lab
Drying samples for analyzing metabolites via LCMS and GCMS
Very straight-forward and easy to use - just a press of a button and your good to go. It has many different setting to dry any solvent type you may be working with. You can dry samples for an hour or over night - whatever best fits your workflow. I've had this in my lab for over 2 years, and there hasn't been any issues.
Review Date: 10 Nov 2020 | Genevac
Just works
speed vacuum desiccator
Works well - dries samples quickly and has nice temperature settings.
Review Date: 15 May 2017 | Genevac
Essential part of the lab
Sample formatting
Used for high value product preparation, the system provides excellent versatility from microtiter plates to EPA vials, it is now an essential part of the lab.
Review Date: 10 Nov 2016 | Genevac
Good benchtop item for use in a synthesis lab. Good for taking off high boiling solvents e.g. DMF. Also used for HPLC fractions and 96 well plates. A very versatile piece of equipment.
Review Date: 23 Sept 2011 | Genevac
Using the most advanced proven technology in evaporation science, the third generation of the EZ-2 Series has been designed specifically for solvent removal in life science research; be that concentration of samples or complete drying.
The innovative design of the EZ-2 Series presents many advantages for working in parallel within synthesis chemistry, analytical sample preparation and for general-purpose solvent removal needs in life science laboratories.
At the heart of the evaporator is a solvent resistant, oil-free vacuum pump, and the high efficiency, defrost-free, SpeedTrap™, which traps all solvents as liquids, even water. Solvents collect in the insulated, plastic coated glass vessel, enabling the user to see the progress of evaporation and determine when the trap should be emptied.
The EZ-2 Elite has a special auto-draining collection vessel fitted to the SpeedTrap, which uses the very powerful Scroll pump. The Elite can therefore evaporate the highest boiling solvents such as DMSO and perform the Genevac LyoSpeed fast lyophilisation method for HPLC fractions.
There is a low-cost option available on the Standard, Plus and Elite that allows the routine use of hydrochloric acid and aggressive solvents. By building key elements in Hastelloy®, glass or PTFE, full protection against acid chlorides is achieved. New to the HCl Resistance option is the ability to evaporate concentrated nitric acid. This option must be specified when ordering, as it cannot be retrofitted. All EZ-2 models are resistant to routine use of high concentrations of TFA as standard.
An additional option is available to allow safe operation for those wishing to use highly explosive solvents, such as pentane or diethyl ether - the inert gas purge system. This system can also be used to preserve oxygen or moisture sensitive samples under an inert gas blanket until the user returns to the evaporator.
The EZ-2 Series can also accommodate a wide selection of sample holders, including round-bottom flasks up to 500ml, tubes up to 160mm long (including Dionex ASE® and Radleys Carousel tubes), custom reaction blocks, and shallow or deep-well microtitre plates.
EZ-2 Series Models:
- The Standard (EZ-2) is suitable for water and volatile solvents
- The Envi (EZ-2 Envi) is recommended for concentration of volatile solvents
- The Plus (EZ-2 Plus) is recommended for solvents with boiling points upto 165°C
- The Elite (EZ-2 Elite) is recommended for solvents with boiling points upto 220°C
Introduction to Solvent Evaporation
Solvent removal is an essential process for sample preparation across a range of applications in many industries. Many sample formats and solvents are used with no single technique providing a universal solution, but despite the variety of specifics evaporation is well-understood and relatively uncomplicated.
Development of a Simple and Rapid Sample Preparation Method for the Detection and Quantification of Algal Toxins in Surface Water
Several non-spectroscopic methods are currently used for the detection of algal toxins in water and most published studies utilize solid-phase extraction (SPE) as a sample preparation technique. However, this technique can be time consuming. In this application note, direct solvent evaporation using the Genevac EZ-2 evaporator is evaluated as a means to reduce to improve detection efficiency. It was found that this method improved reproducibility, decreased analysis time and reduced the risk of cross contamination when compared to SPE.
Advances in Sample Preparation for Metabolite Profiling
This application report describes a procedure, based on a semi-preparative LC-MS-MS system, for the determination of the biological activity and the definitive structure of metabolites in vitro assays or in vivo studies.
Evaluation of Evaporative Sample Preparation Techniques for Alcohol Markers and Drugs of Abuse in Hair Samples
This application report assesses the suitability of the Genevac EZ-2 centrifugal vacuum evaporator for sample preparation while investigating the potential for cross contamination using a hair alcohol marker and a drugs of abuse (DoA) solution. The recovery of amphetamine is also evaluated.
Evaluation of Evaporative Sample Preparation Techniques using the Genevac EZ-2
When introducing any new piece of instrumentation or equipment into a highly controlled environment such as an environmental analysis laboratory, the new unit should be validated to ensure that it has equivalent or better performance to the existing equipment. Any impact on the testing methods can then be fully understood and the testing methods re-validated if necessary. With regard to sample concentration and evaporation technology the most important issue is sample recovery, especially for very volatile analytes. This application note describes Laboratoire départemental d’analyses de la Drôme’s (LDA26’s) evaluation of the Genevac EZ-2 and a comparison of two existing methodologies.
Evaluation of Evaporative Sample Preparation Techniques for Alcohol Markers and Drugs of Abuse in Hair Samples
Read this case study and learn how the analysis of hair can be a useful tool in many forensic and clinical applications to establish drug use, trends of use and in the assessment of chronic alcohol consumption. Using the Genevac evaporation programme within these DoA produces, enables the excellent recovery of amphetamine, for example, which is renowned for its volatility.
Integrated Benchtop Solvent Evaporation with the Genevac EZ2 Elite
Watch this video to learn how the EZ2 Elite from Genevac offers safe and efficient evaporation of your solvents in a compact design that is resistant to most acids even TFA. Specialist models resistant to hydrochloric acid are also available to suit the needs of your research. The Genevac Scroll Pump allows you to reach very low pressures, and so very high boiling point solvents like DMSO can be evaporated, which is not possible on other EZ2 models.
Genevac EZ-2 Series Evaporator
Watch this video to discover the EZ-2 Series Evaporator from Genevac. The EZ-2 Series has been designed specifically for solvent removal in many areas of scientific research, whether concentration of samples or complete drying is required. The EZ-2 Elite is recommended for solvents with boiling points up to 220°C.
An Informative Introduction to Evaporation
EZ-2 Series Evaporators Designed to Exceed Most Solvent Removal Needs
Versatile evaporator available in different optimized configurations
































