- Ease of use
- After sales service
- Value for money

Related video
Description
The new epMotion 5070 Workstation enables fast and reproducible dispensings by way of pipetting, dispensing and other dispensing variants. Extensive previous skills or long training are not necessary.
Sequences previously carried out manually can now be transferred easily and quickly to the epMotion 5070 Workstation. Tried and true pipetting procedure routines have been maintained. As a result of this great similarity to manual pipettes and to the familiar manual work method, a move to the automatic version is eased considerably. Familiar techniques can be quickly and easily transferred to the epMotion 5070.
Operation takes place over the keyboard of the connected Control Panel. The connected mouse enables free movement of the cursor over the integrated screen. An almost intuitive operation with greater flexibility in the application is made possible as a result. The user is led step by step through the software and prompted to carry out the necessary actions. The blocking of valuable lab surface is also avoided by doing without operation over the PC.
All of the following steps take place fully automatically following the insertion of the dispensing tool: The dispensing tool attaches the pipette tip, the liquid to be isolated is taken up from a supply and dispensed into one or more target tubes. Normally the dispensing is concluded following the ejection of the pipette tip. Optical sensors control and guarantee the reliability of the procedure:
• Testing of liquid quantities
• Testing of the existing pipette tip type with the programming
• Testing of the existing tubes with the programming
The epMotion 5070 Workstation enables quick filling of plates with, for example, buffer in the 384-well scale. It is also possible to equip a MTP 384-well from other formats (e.g. 4 x MTP 96-well).
Applications include:
- Plug'n'Prep® nucleic acid extraction
- Real-time PCR set-up
- Cell maintenance and cell based assays
- Clinical diagnostics & research
- Chemical and material research
- and all routine pipetting tasks
Application notes and news
- Validation of the Eppendorf epMotion® 5075 TMX System for use with an Automated Forensic DNA Extraction Kit.
- Automated Seeding of HeLa Cells in Various Cell Densities in 24-well Cell Culture Plates Using the epMotion...
- Eppendorf Deepwell Plate: Determination of residual volumes during use with the automated pipetting system ...
- Performing Cytotoxicity Assays with different substances on the Eppendof epMotion® 5070/5075
- Automated seeding of HeLa cells in various cell densities in 24-well cell culture plates using the epMotion...
- Automated media change in 24-well plates for HeLa cells using the epMotion® 5070 CB
- Reproducible and Easy Automated Purification
- New Software Speeds Validation of Automated Liquid Handling Processes
- Enter Eppendorf Prize Draw and Learn About epMotion Automated Pipetting Systems at ELRIG 2010
- Eppendorf North America at the Annual Meeting for the Society of Neuroscience
- All-singing automation – ‘It’s called epMotion’
- Eppendorf’s ‘top dog’ awarded to a Pfizer scientist
- Eppendorf real-time PCR helps target rare cells
Reviews
Claudia Wolft![]() Status: See all reviews Member since 2012 Organization: Technische Universität München Read more » | RATING: 4.0 ![]()
"Very robust and gives reproducible results. Have had some problems when using viscous samples." |
Michael Stangegaard![]() Status: See all reviews Member since 2008 Organization: University of Copenhagen; Section of Forensic Genetics Read more » | RATING: 4.7 ![]()
"Easy and simple to program and use. The tip-counting feature and deck-check features prevents loading failures. For simple pipetting using the same script over and over this is a nice system. The downsides are: only 4 deck positions (PCR setup not possible), manual change of tool required if needed, slow when handling many samples." |
Petra Olivova![]() Status: See all reviews Member since 2011 Organization: Genzyme Read more » | RATING: 5.0 ![]()
"We purchased this unit in January 2012. It is extremely easy to program and use, it is very robust and applicable to many tasks (some of which were not even mentioned by vendor). We love it!" |
Wale Rufai![]() Status: See all reviews Member since 2010 Organization: Amgen Read more » | RATING: 4.3 ![]()
"Easy to program, on average it takes 60 minutes to develop a program. Cost efficient compared to other automated liquid handlers. Small footprint, can fit in and on lab benches that have limited spacing." |
CYNTHIA KUK![]() Status: See all reviews Member since 2011 Organization: VAN ANDEL RESEARCH INST. Read more » | RATING: 4.0 ![]()
"Helps with repetitive pipetting." |
Wale Rufai![]() Status: See all reviews Member since 2010 Organization: Amgen Read more » | RATING: 5.0 ![]()
"The system has very simple programming." |
Cornelia Hildebrandt![]() Status: See all reviews Member since 2006 Organization: IBMT Institute for Medical Technic Read more » | RATING: 4.0 ![]()
"A very good product for microarray analyses." |