contrAA® Series - High-Resolution Continuum Source AAS

Analytik Jena Analytical Instrumentation
contrAA® Series - High-Resolution Continuum Source AAS

Description

 

Novel Atomic Absorption Spectrometers Enable Analysis of Non-Metals for the First Time

The High Resolution Continuum Source AAS technology (HR-CS AAS) now also enables the detection of non-metals using an AAS instrument, the contrAA® from Analytik Jena. Thanks to a Xenon lamp as continuous radiation source, any wavelength is available for measurement on the contrAA® – including molecular bands. By converting the non-metals into characteristic molecules, these can be detected using molecular absorption spectrometry (MAS).

Without extensive sample preparation the non-metals in the graphite furnace are converted quantitatively into the target molecule and then detected by way of spectrometry. It does not matter whether the non-metals are free anions or organically or inorganically bound in the sample. Thus a simple, fast and reliable spectrometric method for the detection of non-metals in almost any matrix and across a wide range of concentrations is available for the first time, e.g. of fluorine in water or toothpaste or of phosphorus in animal feed or seepage water.

Graphite furnace HR-CS MAS is as precise, robust and interference-free as graphite furnace AAS and not subject to any limitations regarding the chemical bonding, the pH value, the solvent or the sample matrix, reducing sample preparation to a minimum.

Simultaneous Multi-Element Analysis with High Resolution Continuum Source AAS (HR-CS AAS)
Analytik Jena furthermore enhances the range of applications of the revolutionary contrAA® product series by introducing the simultaneous analysis of several absorption lines in the measured spectral range. This offers great benefits especially in the relatively time-consuming graphite furnace technology, because several elements can be detected simultaneously using a single atomization.

One application example is the simultaneous detection of Ni, Fe and V in waste water. Low vanadium concentrations in the µg/l range are detected in parallel to Ni and Fe concentrations in the mg/l range in process water. The simultaneous measurement triples your sample throughput and the unique three-dimensional spectrum representation supports users in the rapid optimization of the atomizing parameters without additional empirical intermediate steps.

Simultaneous multi-element analysis with the contrAA® series offers: 
• Increase of the sample throughput
• Easy optimization of methods
• Savings in measuring time and sample volumes

HR-CS AAS in the contrAA® – from the technology leader in Jena!

Feedback

Request info

To:Analytik Jena Analytical Instrumentation
From:
Please contact me / call me with the contrAA® Series - High-Resolution Continuum S...,

I am looking to purchase in /

.
About you

Write a review

Sharing your experience will help scientists like you. Achieve Reviewer Status and Win an iPad 3 (All reviews published will be entered into the next drawing on May 31st 2013).

  
Your Email

 



Ease of use

After sales services

Value for money

WATCH:
The benefits of becoming a reviewer
Share your opinions...()
HINTS & TIPS
Give reasons for the star ratings you have awarded for each area.
Would you recommend this to a colleague?
What would you like to have known about equipment and consumables before you purchased?



Join 200,000 Scientists Online

Become a member for FREE access to:

  • 250,000 full product and supplier listings
  • 10,000 user reviews and comments
  • Daily news and videos
  • 2,500 application notes and videos
  • 2,000 of the best jobs in Science

Don't miss out!

Join The Community Today