Acclaim® 120 C18 Reversed-Phase LC Column

Acclaim® 120 C18 Reversed-Phase LC Column
 4.0/5.0 (1 review)

Thermo Fisher Scientific

High Performance Reversed-Phase Columns for the Separation of Small Molecules. The Acclaim® 120 columns are designed for high resolution reversed-phase separations. The very high surface coverage...read more

Request Pricing





Receive your quote directly from Thermo Fisher Scientific for Acclaim® 120 C18 Reversed-Phase LC Column

Reviews

Arcady Braun


Status:


See all reviews
Member since 2011

Organization:
Moscow State University
Read more »
RATING: 4.0

  • 5 out of 5EASE OF USE
  • 5 out of 5AFTER SALES SERVICE
  • 2 out of 5VALUE FOR MONEY




Review date: 20 Sep 2011

Acclaim® 120 C18 Reversed-Phase LC Column

"One of the best columns available."

Description

 

High Performance Reversed-Phase Columns for the Separation of Small Molecules.

The Acclaim® 120 columns are designed for high resolution reversed-phase separations. The very high surface coverage and very low metal content together result in columns with excellent efficiencies. These columns provide exceptional performance for a variety of applications in the pharmaceutical, chemical, environmental, and food separations areas.

Acclaim 120 C18 columns have high surface coverage, resulting in high-capacity columns. They are stable between pH 2 and 8 and available in 3 and 5 μm particles sizes, and 4.6, 3.0, and 2.1 mm-diameters, with an average pore diameter of 120 Å. Acclaim 120 C18 is also available in 2.2µm RSLC format (see Acclaim Rapid Separation LC columns section for more details). All phases are LC/MS compatible because of the low silica bleed that results from the stable bonding procedure.


Acclaim® 120 C18 Reversed-Phase LC Column Features:

  • Ultrapure silica with high-density bonding for low silanol activity
  • Very high efficiencies for maximum resolution
  • Reproducible manufacturing practices for reproducible column-to-column performance
  • LC/MS compatible

Column Details:

  • Particle Size: 3, 5 µm
  • Pore Size: 120 Å
  • Length: 50, 100, 150, 250 mm
  • ID: 2.1, 3.0, 4.6 mm

Feedback

Request info

To:Thermo Fisher Scientific
From:
Please contact me / call me with the Acclaim® 120 C18 Reversed-Phase LC Column,

I am looking to purchase in /

.
About you

Write a review

Sharing your experience will help scientists like you. Achieve Reviewer Status and Win an iPad air (All reviews published will be entered into the next drawing on May 30th 2014).

  
Your Email

 



Ease of use

After sales services

Value for money

WATCH:
The benefits of becoming a reviewer
Share your opinions...()
HINTS & TIPS
Give reasons for the star ratings you have awarded for each area.
Would you recommend this to a colleague?
What would you like to have known about equipment and consumables before you purchased?



Why make an enquiry with SelectScience?

  • EASY It’s quick and simple to do
  • FAST Your enquiry will be delivered straight to the manufacturer
  • FREE You’re under no obligation
  • SECURE We only pass your details on to trusted suppliers at your request
  • SAVE TIME Submit your details once and make multiple enquiries
SelectScience Trusted Banner